Establishment of diagnostic reference levels in cardiac computed tomography
Open accessAbstract
The aim of this study was to determine diagnostic reference levels (DRLs) for cardiac computed tomography (CCT) in Jordan. Volume computed tomography dose index (CTDI vol) and dose–length product (DLP) were collected from 228 CCTs performed at seven Jordanian hospitals specialized in cardiac CT. DRLs for cardiac CT were defined at the 75th percentile of CTDI vol and DLP. CTDI vol and DLP were collected from 30 successive cardiac CT in each center except for one center (18 scans). The 75th percentile of the CTDI vol and the DLP of the centers calculated from mixed retrospective and prospective gated modes were 47.74 milligray (mGy) and 1035 mGy/cm, respectively. This study demonstrated wide dose variations among the surveyed hospitals for cardiac CT scans; there was a 5.1‐fold difference between the highest and lowest median DLP with a range of 223.2–1146.7 mGy/cm. Differences were associated with variations in the mAs and kVp. This study confirmed large variability in CTDI vol and DLP for cardiac CT scans; variation was associated with acquisition protocols and highlights the need for dose optimization. DRLs are proposed for CCT; there remains substantial potential for optimization of cardiac CT examinations for adults in Jordan.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In a distinct study, Rawashdeh et al (2019) evaluated 228 cardiac CT examinations from seven hospitals in Jordan.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [119]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
Smith‐Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,467
2007 Recommendations of the International Commission on Radiological Protection
Publ., I. (2008) · Medical Entomology and Zoology · Cited by 1,796
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
1990 Recommendations of the International Commission on Radiological Protection
Shapiro, B. (1992) · European Journal of Radiology · doi:10.1016/0720-048x(92)90214-t · Cited by 958
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., et al. (2008) · International journal of cardiac imaging · doi:10.1007/s10554-008-9308-2 · Cited by 564
Hirai, N., Horiguchi, J., Fujioka, C., et al. (2008) · Radiology · doi:10.1148/radiol.2482071804 · Cited by 294
Smith‐Bindman, R., Wang, Y., Chu, P., Chung, R., Einstein, A. J., Balcombe, J. N., Cocker, M. R., Das, M., Delman, B. N., Flynn, M., et al. (2019) · BMJ · doi:10.1136/bmj.k4931 · Cited by 244
Radiation exposure of the UK population from medical and dental x-ray examinations
Hart, D. B., & Wall, B. F. (2001) · Cited by 196
Research works printed but not linked: 1
- Shrimpton P, 2005, Doses from computed tomography (CT) examinations in the UK‐2003 review
Cited by
Sorted by citations
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
“10 In a distinct study, Rawashdeh et al (2019) evaluated 228 cardiac CT examinations from seven hospitals in Jordan.”
Metadata
- Authors
- Rawashdeh, M., Saade, C., Zaitoun, M., Abdelrahman, M., Brennan, P., Alewaidat, H., & McEntee, M. F.
- Affiliations
- Jordan University of Science and Technology (JO)
- American University of Beirut Medical Center (LB)
- The University of Sydney (AU)
- University College Cork (IE)
- Corresponding author
- Rawashdeh, Mohammad
- ORCID
- Venue
- Journal of Applied Clinical Medical Physics
- Publisher
- Wiley
- Published
- 2019-08-30
- Volume
- 20
- Issue
- 10
- Pages
- 181-186
- ISSN
- 1526-9914 (ISSN-L)
- PMC
- PMC6807208
- OpenAlex
- W2970073198
- Cited by
- 21
- References
- 32
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 5 · 2021: 2 · 2020: 1
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Applied Clinical Medical Physics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Arrow@dit (Dublin Institute of Technology) (acceptedVersion)
- Cork Open Research Archive (University College Cork, Ireland) (submittedVersion, cc-by)
- Greater South Information System
- Funders
- Jordan University of Sciences and Technology (20180322)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- diagnostic reference levels, cardiac CT, radiation dose, CTDIvol, dose-length product, dose optimization, acquisition protocol, Jordan
- MeSH terms
- Computed Tomography Angiography, Adult, Algorithms, Female, Hospitals, Humans, Image Processing, Computer-Assisted, Jordan, Male, Middle Aged, Prognosis, Prospective Studies, Quality Assurance, Health Care, Radiation Dosage, Reference Standards, Retrospective Studies, Radiography, Thoracic, Tomography, X-Ray Computed, Phantoms, Imaging, Cardiac-Gated Imaging Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Establishment of diagnostic reference levels in cardiac computed tomography. https://app.cochat.ai/papers/10.1002/acm2.12711
- The paper
- Rawashdeh, M., Saade, C., Zaitoun, M., Abdelrahman, M., Brennan, P., Alewaidat, H., & McEntee, M. F. (2019). Establishment of diagnostic reference levels in cardiac computed tomography. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.12711