Cited by 21Radiation Dose and ImagingCardiac Imaging and DiagnosticsAdvanced Radiotherapy Techniques

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Establishment of diagnostic reference levels in cardiac computed tomography

Open access

Abstract

The aim of this study was to determine diagnostic reference levels (DRLs) for cardiac computed tomography (CCT) in Jordan. Volume computed tomography dose index (CTDI vol) and dose–length product (DLP) were collected from 228 CCTs performed at seven Jordanian hospitals specialized in cardiac CT. DRLs for cardiac CT were defined at the 75th percentile of CTDI vol and DLP. CTDI vol and DLP were collected from 30 successive cardiac CT in each center except for one center (18 scans). The 75th percentile of the CTDI vol and the DLP of the centers calculated from mixed retrospective and prospective gated modes were 47.74 milligray (mGy) and 1035 mGy/cm, respectively. This study demonstrated wide dose variations among the surveyed hospitals for cardiac CT scans; there was a 5.1‐fold difference between the highest and lowest median DLP with a range of 223.2–1146.7 mGy/cm. Differences were associated with variations in the mAs and kVp. This study confirmed large variability in CTDI vol and DLP for cardiac CT scans; variation was associated with acquisition protocols and highlights the need for dose optimization. DRLs are proposed for CCT; there remains substantial potential for optimization of cardiac CT examinations for adults in Jordan.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/acm2.12711

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Research works printed but not linked: 1

  1. Shrimpton P, 2005, Doses from computed tomography (CT) examinations in the UK‐2003 review

Cited by

Sorted by citations

See all 21

Metadata

Authors
Rawashdeh, M., Saade, C., Zaitoun, M., Abdelrahman, M., Brennan, P., Alewaidat, H., & McEntee, M. F.
Affiliations
  • Jordan University of Science and Technology (JO)
  • American University of Beirut Medical Center (LB)
  • The University of Sydney (AU)
  • University College Cork (IE)
Corresponding author
Rawashdeh, Mohammad
Venue
Journal of Applied Clinical Medical Physics
Publisher
Wiley
Published
2019-08-30
Volume
20
Issue
10
Pages
181-186
ISSN
1526-9914 (ISSN-L)
OpenAlex
W2970073198
Cited by
21
References
32
Citations by year
2026: 3 · 2025: 3 · 2024: 4 · 2023: 3 · 2022: 5 · 2021: 2 · 2020: 1
FWCI
1.32
Type
journal article
Language
en
Open access
Locations
  • Journal of Applied Clinical Medical Physics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Arrow@dit (Dublin Institute of Technology) (acceptedVersion)
  • Cork Open Research Archive (University College Cork, Ireland) (submittedVersion, cc-by)
  • Greater South Information System
Funders
Jordan University of Sciences and Technology (20180322)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
Keywords
diagnostic reference levels, cardiac CT, radiation dose, CTDIvol, dose-length product, dose optimization, acquisition protocol, Jordan
MeSH terms
Computed Tomography Angiography, Adult, Algorithms, Female, Hospitals, Humans, Image Processing, Computer-Assisted, Jordan, Male, Middle Aged, Prognosis, Prospective Studies, Quality Assurance, Health Care, Radiation Dosage, Reference Standards, Retrospective Studies, Radiography, Thoracic, Tomography, X-Ray Computed, Phantoms, Imaging, Cardiac-Gated Imaging Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Establishment of diagnostic reference levels in cardiac computed tomography. https://app.cochat.ai/papers/10.1002/acm2.12711
The paper
Rawashdeh, M., Saade, C., Zaitoun, M., Abdelrahman, M., Brennan, P., Alewaidat, H., & McEntee, M. F. (2019). Establishment of diagnostic reference levels in cardiac computed tomography. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.12711