Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 97 of the 97 references it cites were found in a registry or an index; 34 of the 105 sources its claims cite were checked for support.

Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction

Open access
Oglat, Ammar, Shdaifat, Suhaib, Sayah, Mohannad, Abukonna, Ahmed, Khogali, Wadah · 2026 · Drug, Healthcare and Patient Safety

Abstract

Computed tomography (CT) contributes substantially to medical radiation exposure, making diagnostic reference levels (DRLs) essential for dose optimization and patient protection.

Overview

CoChat Summary

TL;DR

This is a structured narrative review of CT diagnostic reference levels (DRLs) worldwide, with focused attention to Jordan. The paper argues that Jordan has useful local dose data but still lacks a unified national CT DRL framework, and it recommends standardized reporting, auditing, and periodic revision.

Key findings

  • The review found marked cross-country variation in CT DRL methodology, updating cycles, and regulatory integration.
  • In the UK, the current adult head CT DRL is reported as 47 mGy CTDIvol and 790 mGy·cm DLP, based on a nationwide study of more than 47,000 CT examinations across 182 scanners.
  • In Uganda, a national adult head CT DRL was reported as 56.02 mGy CTDIvol and 1260.3 mGy·cm DLP from a multicenter survey across 13 institutions.
  • In Jordan, one cited study of more than 2,000 CT scans (2021–2022) proposed adult head CT DRLs of 65.1 mGy CTDIvol and 945 mGy·cm DLP; another Jordan study of 228 cardiac CT examinations from seven hospitals reported 47.7 mGy CTDIvol and 1,035 mGy·cm DLP, with more than fivefold variation across institutions.

Methods

  • The paper is a structured narrative review of CT DRLs worldwide, with a focused appraisal of evidence from Jordan.
  • Literature and guidance were searched in PubMed, Scopus, Web of Science, and Google Scholar, plus reference lists; search terms included CT, DRL, CTDIvol, DLP, SSDE, radiation dose, dose optimization, and Jordan.
  • Included sources addressed adult or pediatric CT DRLs, local/national DRL surveys, CT dose metrics, or international guidance; findings were synthesized narratively.

Limitations

  • The paper does not report a formal systematic-review quality assessment or meta-analysis; this is evident from the stated structured narrative review design.
  • The review relies on the available published studies and guidance documents and explicitly notes evidence gaps and fragmented practices in Jordan, indicating incomplete national data.
  • The text makes evident that some cited country comparisons are not directly comparable because DRLs vary by methodology, patient selection, and update cycle; this is described in the paper rather than presented as a study limitation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2147/dhps.s595721

Cites

97 of 97 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Global DRLs values for CT examinations.
Figure 1 Global DRLs values for CT examinations.CC BY-NC · PubMed Central
Figure 2 Comparison of suggested DRLs (Jordan vs UK) for CT examinations.
Figure 2 Comparison of suggested DRLs (Jordan vs UK) for CT examinations.CC BY-NC · PubMed Central

Verification

Claims the paper makes

26 Valid · 7 Not valid · 51 Not checked · 33 Own results and interpretations

20 more claims · 3 with their cited sources checked

Create a free account to see all 117 claims and to verify the 6 references still open.

See all claims — free account
  • Probably not a substantial claim. 66
  • It may state two separate claims as one. 57
  • Borderline: one of the tests for a substantial claim is unclear. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 97 references

Research works printed but not linked: 25

  1. 2018, Radiation Protection No. 185 European Guidelines on Diagnostic Reference Levels for Paediatric Imaging
  2. Oglat, 2022, Jordan J Biological Sci, 15, 2
  3. Johnson, 2009, Radiol, 39, 1059
  4. Murugan, 2025, Am J Psychiatr Rehabil, 28, 108
  5. 2012, Radiation Dose From Multidetector CT
  6. 2025, A Clinical Lens on Pediatric Engineering: Pioneering Science and Technology for Cutting-Edge Patient Care
  7. Hussain, 2025, J Shoulder Elbow Surg, 2025, 1
  8. 2022, Healthcare
  9. Najjar, 2023, 15, e41623
  10. Sohu, 2022, World J Radiol, 16, 47
  11. Malone J, Holmberg O, Simeonov G. Justification of medical exposure in diagnostic imaging. In Proceedings of International Workshop by the International Atomic Energy Agency (IAEA). 2009.
  12. Dudhe, 2024, Cureus, 16, 1
  13. 2018, Dose, Benefit, and Risk in Medical Imaging
  14. 2013, Radiological Safety and Quality: Paradigms in Leadership and Innovation
  15. 2015, Optimisation and Establishment of Diagnostic Reference Levels in Paediatric Plain Radiography
  16. 2016, Future Developments and Trends in Use of Picture Archiving and Communication Systems
  17. 2019, Digital Radiography: Physical Principles and Quality Control
  18. Kiragga, 2023, Res Square, 2683913
  19. Alenazi, 2025, J Radiat Res Appl Sci, 18, 101371
  20. Alkhidir, 2019, IOSR J Dent Med Sci, 18, 81
  21. 2022, Setting up a Cancer Centre: A WHO-IAEA Framework
  22. Bottollier-Depois, 2020, EURADOS Report, 4, 1
  23. 2015, US National Diagnostic Reference Levels: Closing the Gap
  24. 2025, The Sixth Asian Radiology Summit the Diagnostic Reference Levels (Drls): “asia Safe”—current Situation in Asian Countries
  25. Masoomi, 2020, medRxiv, 2020, 20198176

Cited by

See all 1

Metadata

Authors
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W.
Affiliations
  • Hashemite University (JO)
  • Al-Hussein Bin Talal University (JO)
  • Liwa University (AE)
Corresponding author
Oglat, Ammar
Venue
Drug, Healthcare and Patient Safety
Published
2026-05
Volume
Volume 18
Pages
1-16
ISSN
1179-1365 (ISSN-L)
OpenAlex
W7160054358
Cited by
0
References
97
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
  • Drug Healthcare and Patient Safety (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by-nc)
  • Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
computed tomography, diagnostic reference levels, radiation dose reduction, patient radiation protection, CTDIvol, dose-length product, size-specific dose estimate, pediatric CT, inter-institutional variability, Jordan

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction. https://app.cochat.ai/papers/10.2147/dhps.s595721
The paper
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026). Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction. Drug, Healthcare and Patient Safety. https://doi.org/10.2147/dhps.s595721

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.