Cited by 173Radiomics and Machine Learning in Medical ImagingBrain Tumor Detection and ClassificationImage Retrieval and Classification Techniques

Impact of image preprocessing methods on reproducibility of radiomic features in multimodal magnetic resonance imaging in glioblastoma

Open access
Moradmand, Hajar, Aghamiri, Seyed Mahmoud Reza, Ghaderi, Reza·2020·Journal of Applied Clinical Medical Physics

Abstract

To investigate the effect of image preprocessing, in respect to intensity inhomogeneity correction and noise filtering, on the robustness and reproducibility of the radiomics features extracted from the Glioblastoma (GBM) tumor in multimodal MR images (mMRI). In this study, for each patient 1461 radiomics features were extracted from GBM subregions (i.e., edema, necrosis, enhancement, and tumor) of mMRI (i.e., FLAIR, T1, T1C, and T2) volumes for five preprocessing combinations (in total 116 880 radiomics features). The robustness and reproducibility of the radiomics features were assessed under four comparisons: (a) Baseline versus modified bias field; (b) Baseline versus modified bias field followed by noise filtering; (c) Baseline versus modified noise, and (d) Baseline versus modified noise followed bias field correction. The concordance correlation coefficient (CCC), dynamic range (DR), and interclass correlation coefficient (ICC) were used as metrics. Shape features and subsequently, local binary pattern (LBP) filtered images were highly stable and reproducible against bias field correction and noise filtering in all measurements. In all MRI modalities, necrosis regions (NC: n ̅ ~449/1461, 30%) had the highest number of highly robust features, with CCC and DR >= 0.9, in comparison with edema (ED: n ̅ ~296/1461, 20%), enhanced (EN: n ̅ ~ 281/1461, 19%) and active‐tumor regions (TM: n ̅ ~254/1461, 17%). The necrosis regions (NC: ~ 449/1461, 30%) had a higher number of highly robust features (CCC and DR >= 0.9) than edema (ED: ~ 296/1461, 20%), enhanced (EN: ~ 281/1461, 19%) and active‐tumor (TM: ~ 254/1461, 17%) regions across all modalities. Furthermore, our results identified that the percentage of high reproducible features with ICC >= 0.9 after bias field correction (23.2%), and bias field correction followed by noise filtering (22.4%) were higher in contrast with noise smoothing and also noise smoothing follow by bias correction. These preliminary findings imply that preprocessing sequences can also have a significant impact on the robustness and reproducibility of mMRI‐based radiomics features and identification of generalizable and consistent preprocessing algorithms is a pivotal step before imposing radiomics biomarkers into the clinic for GBM patients.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/acm2.12795

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • There is currently no consensus on how to perform image pre-processing steps for MR images in radiomics, and it is one of the open challenges in radiomic processing.

    “There is currently no consensus on how to perform these steps for MR images in radiomics, and is one of the many open challenges in radiomic processing [18, 44].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Moradmand, H., Aghamiri, S. M. R., & Ghaderi, R.
Affiliations
Shahid Beheshti University (IR)
Corresponding author
Ghaderi, Reza
Venue
Journal of Applied Clinical Medical Physics
Publisher
Wiley
Published
2019-12-27
Volume
21
Issue
1
Pages
179-190
ISSN
1526-9914 (ISSN-L)
OpenAlex
W2997189273
Cited by
173
References
50
Citations by year
2026: 8 · 2025: 21 · 2024: 31 · 2023: 30 · 2022: 40 · 2021: 31 · 2020: 12
FWCI
13.70
Type
journal article
Language
en
Open access
Locations
  • Journal of Applied Clinical Medical Physics (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
  • Life Sciences › Neuroscience › Neurology › Brain Tumor Detection and Classification
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Image Retrieval and Classification Techniques
Keywords
radiomics, glioblastoma, image preprocessing, bias field correction, noise reduction, reproducibility, multimodal MRI, intensity inhomogeneity, local binary pattern, tumor necrosis, tumor edema, tumor enhancement, FLAIR, T1-weighted imaging, T2-weighted imaging, feature robustness, shape features, tumor subregions, interobserver variability
MeSH terms
Algorithms, Female, Glioblastoma, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review