Integration of sarcopenia screening into radiotherapy planning: Validation of a time‐efficient SMI measurement method using MIM software in prostate cancer
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Sarcopenia (SP) affects 43.8% of men with prostate cancer (PCa), correlating with higher all‐cause mortality and reduced quality of life. Systematic SP screening could reduce treatment complications and improve prognosis. Although several validated software tools exist for CT‐based skeletal muscle assessment, their implementation in routine clinical practice remains limited due to time constraints, operator dependency, and lack of integration into radiotherapy planning systems. Purpose: We aimed to validate a new SP screening method using MIM® software, a program commonly used in radiotherapy planning, to facilitate its implementation in daily practice. Methods: In 41 patients with PCa, Skeletal Muscle Index (SMI) was retrospectively calculated using MIM® and compared with the validated ImageJ® method. Agreement was assessed via Bland‐Altman analysis, while sarcopenic status was classified using literature‐based SMI thresholds. Measurement time and reproducibility were evaluated using Wilcoxon tests, Intraclass Correlation Coefficient (ICC), and Fleiss kappa coefficients (κ). Additionally, an automated MIM‐workflow was developed and compared to the semi‐manual MIM‐method in terms of agreement and processing time. Results: The cohort had a median age of 71 years, with 66% overweight or obese and 22% classified as sarcopenic. The new method demonstrated high concordance with the validated method (mean SMI difference: −0.04 cm 2 /m 2 , p = 0.23), while significantly reducing calculation time (3.5 ± 1 min vs. 10 ± 1 min, p < 0.001). Reproducibility was excellent, with an ICC of 0.99 for SMI and perfect agreement on sarcopenic classification ( κ = 1). The automated MIM‐workflow further decreased processing time (median 3.2 min vs. 3.5 min, p < 0.001) but yielded slightly higher SMI values (mean difference: 2.3 cm 2 /m 2 , p < 0.0001). Conclusion: MIM® software provides a reproducible, reliable, and time‐efficient alternative for SP screening, allowing radiation‐oncologists to implement this assessment immediately into routine radiotherapy planning. Although the automated MIM‐workflow requires further calibration to correct for systematic SMI overestimation, it represents a promising step toward full automation and broader clinical integration of SP assessment within radiation‐oncology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarcopenia: revised European consensus on definition and diagnosis
Cruz-Jentoft, A. J., Bahat, G., Bauer, J., Boirie, Y., Bruyère, O., Cederholm, T., Cooper, C., Landi, F., Rolland, Y., Sayer, A. A., et al. (2019) · Age and Ageing · doi:10.1093/ageing/afy169 · Cited by 13,818
Approaches to Assessment of Muscle Mass and Myosteatosis on Computed Tomography: A Systematic Review
Amini, B., Boyle, S. P., Boutin, R. D., & Lenchik, L. (2019) · The Journals of Gerontology: Series A · doi:10.1093/gerona/glz034 · Cited by 391
van Vugt, J. L. A., Levolger, S., Gharbharan, A., Koek, M., Niessen, W. J., Burger, J. W. A., Willemsen, S. P., de Bruin, R. W. F., & IJzermans, J. N. M. (2017) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12158 · Cited by 217
Research works printed but not linked: 28
- 10.1016/j.jgo.2023.101594 · DOI
- 10.1080/01635581.2021.1884731 · DOI
- 10.1016/j.radonc.2024.110663 · DOI · Paper page
- 10.1200/JCO.2012.45.2722 · DOI · Paper page
- 10.1016/j.nut.2018.06.003 · DOI
- 10.1016/S1470‐2045(08)70153‐0 · DOI · Paper page
- 10.20945/2359‐3997000000174 · DOI
- 10.1097/SLA.0000000000000628 · DOI · Paper page
- 10.1038/oby.2007.573 · DOI · Paper page
- 10.2522/ptj.20110380 · DOI · Paper page
- 10.1002/jpen.1036 · DOI
- 10.1016/j.nut.2024.112421 · DOI
- 10.1007/s00261‐017‐1123‐6 · DOI
- 10.1186/s12880‐019‐0316‐6 · DOI
- 10.3390/diagnostics14151696 · DOI
- BlankemeierL DesaiA ChavesJMZ et al.Comp2Comp: open‐source body composition assessment on computed tomography. Published online February 13 2023.http://arxiv.org/abs/2302.06568
- 10.1038/s41598‐025‐96238‐6 · DOI
- 10.1148/ryai.230024 · DOI · Paper page
- 10.1007/s00223‐021‐00914‐4 · DOI
- 10.1002/jpen.1721 · DOI
- 10.1016/j.eururo.2020.09.042 · DOI · Paper page
- 10.5114/aoms/191297 · DOI
- 10.3390/healthcare14111476 · DOI
- 10.1007/s11547‐022‐01450‐3 · DOI · Paper page
- 10.1139/H08‐075 · DOI · Paper page
- 10.1016/S1470‐2045(10)70218‐7 · DOI · Paper page
- 10.1002/jcsm.13160 · DOI
- 10.1093/ageing/afr051 · DOI · Paper page
Metadata
- Authors
- De Bruyn, P., Coquelet, N., Ferreira, P., Michel, M., Descamps, T., Van den Begin, R., Van Gestel, D., & Preiser, J.
- Venue
- Journal of Applied Clinical Medical Physics
- Publisher
- Wiley
- Published
- 2026-07
- Volume
- 27
- Issue
- 7
- ISSN
- 1526-9914
- Cited by
- 0
- References
- 3
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0/ (vor, 8 d)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integration of sarcopenia screening into radiotherapy planning: Validation of a time‐efficient SMI measurement method using MIM software in prostate cancer. https://app.cochat.ai/papers/10.1002/acm2.70694
- The paper
- De Bruyn, P., Coquelet, N., Ferreira, P., Michel, M., Descamps, T., Van den Begin, R., Van Gestel, D., & Preiser, J. (2026). Integration of sarcopenia screening into radiotherapy planning: Validation of a time‐efficient SMI measurement method using MIM software in prostate cancer. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.