Robust control of depth of anesthesia
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a systematic procedure to design both robust PID controllers and robust controllers based on fractional calculus (based on Commande Robuste d'Ordre Non Entier, or CRONE methodology) to regulate the hypnotic state of anesthesia with the intravenous administration of propofol. The objective of the controllers is to provide an adequate drug administration regimen for propofol to avoid under or over dosing of the patients. The controllers are designed to compensate for the patients inherent drug–response variability (uncertainty), to achieve good output disturbance rejection, and to attain good set point response. The performance of the controllers is assessed by calculating typical time domain measures and using the median PE, median absolute PE, divergence, and wobble. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development and Clinical Application of Electroencephalographic Bispectrum Monitoring
Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000) · Anesthesiology · doi:10.1097/00000542-200011000-00029 · Cited by 599 · cited 1×
“Monitoring in anesthesia has changed dramatically over the last 10 years, particularly with the widespread use of pulse oximetry and the development of electroencephalographic assessment of the depth of hypnosis with monitors such as the Aspect Medical BIS monitor [12].”
Population Pharmacokinetics of Propofol: A Multicenter Study
Schüttler, J., & Ihmsen, H. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00017 · Cited by 434 · cited 4×
“The first step consists of calculating the drug plasma concentration using the well-defined propofol PK model published by Schüttler and Ihmsen [16].”
InfluentialClosed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313 · cited 1×
“Although many studies have been performed in automated drug delivery for chronic diseases such as diabetes [1], or for more controlled environments such as perioperative hemodynamic control [2] or the delivery of anesthetic agents in the operating room [3], these studies have had little impact on routine clinical prac…”
CLOSED-LOOP FEEDBACK CONTROL OF PROPOFOL ANAESTHESIA BY QUANTITATIVE EEG ANALYSIS IN HUMANS
SCHWILDEN, H., STOECKEL, H., & SCHÜTTLER, J. (1989) · British Journal of Anaesthesia · doi:10.1093/bja/62.3.290 · Cited by 228 · cited 1×
“[17] used the median frequency of the electroencephalogram (EEG) as an indication of depth of hypnosis and a simple model-based adaptive scheme based on a two-compartment model to adjust propofol infusion in 11 volunteers.”
Absalom, A. R., Sutcliffe, N., & Kenny, G. N. (2002) · Anesthesiology · doi:10.1097/00000542-200201000-00017 · Cited by 212
Quantifying Cortical Activity During General Anesthesia Using Wavelet Analysis
Zikov, T., Bibian, S., Dumont, G. A., Huzmezan, M., & Ries, C. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870255 · Cited by 177
Self-citationStruys, M. M. R. F., Smet, T. D., Greenwald, S. D., Absalom, A. R., Bingé, S., & Mortier, E. P. (2004) · Anesthesiology · doi:10.1097/00000542-200403000-00026 · Cited by 132 · cited 1×
“The disturbance profile shown in Figure 6 was designed to emulate a typical noxious stimuli trajectory of a surgical procedure, see [28] for similar profiles.”
Modeling and closed-loop control of hypnosis by means of bispectral index (BIS) with isoflurane
Gentilini, A., Rossoni-Gerosa, M., Frei, C. W., Wymann, R., Morari, M., Zbinden, A. M., & Schnider, T. W. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936364 · Cited by 124
Automated Anesthesia: Fact or Fantasy?
Glass, P. S. A., & Rampil, I. J. (2001) · Anesthesiology · doi:10.1097/00000542-200107000-00005 · Cited by 65
Bibian, S., Dumont, G. A., Huzmezan, M., & Ries, C. R. (2006) · IFAC Proceedings Volumes · doi:10.3182/20060920-3-fr-2912.00097 · Cited by 18
Self-citation
Cited by
Parvinian, B., Pathmanathan, P., Daluwatte, C., Yaghouby, F., Gray, R. A., Weininger, S., Morrison, T. M., & Scully, C. G. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00220 · Cited by 44
“, 2017), WAVcns (Dumont et al., 2009; Hahn et al., 2012), or auditory evoked response (Elkfafi et al.”
BackgroundMethodInfluential
Metadata
- Authors
- Dumont, G. A., Martinez, A., & Ansermino, J. M.
- Venue
- International Journal of Adaptive Control and Signal Processing
- Publisher
- Wiley
- Published
- 2008-11-04
- Volume
- 23
- Issue
- 5
- Pages
- 435-454
- ISSN
- 0890-6327 (ISSN-L)
- 1099-1115
- OpenAlex
- W2137164841
- Cited by
- 161
- References
- 10
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust control of depth of anesthesia. https://app.cochat.ai/papers/10.1002/acs.1087
- The paper
- Dumont, G. A., Martinez, A., & Ansermino, J. M. (2009). Robust control of depth of anesthesia. International Journal of Adaptive Control and Signal Processing. https://doi.org/10.1002/acs.1087
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.