The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Development and Clinical Application of Electroencephalographic Bispectrum Monitoring
Abstract
UNTIL recently, anesthesiologists lacked the ability to monitor the effects of anesthetics on the brain in terms of “depth” or “adequacy” of anesthesia. Typically, surrogate measures of autonomic activity, such as changes in blood pressure and heart rate, have been used to assess the adequacy or inadequacy of anesthesia. Because it is believed that general anesthetics block consciousness by depressing the central nervous system, and electrical activity of the cerebral cortex can be measured using the electroencephalogram (EEG), it is expected that some component of the EEG should relate to adequacy of anesthesia. Such a relation was first suggested in 1937. 1With the advent of the microcomputer technology, it became possible to reduce the amount of data obtained from an EEG to various processed derivatives. 2Derivatives such as the power spectral edge, median frequency, and zero-crossing frequency, among others, have been described as potential measures of anesthetic effect on the central nervous system. 3–6In that these measures were found to depend on spec ific drug combinations and were not monotonically related to drug effect or clinical response, no gold standard for measuring the entire spectrum of anesthetic effect has been widely accepted.The first and only technology approved by the U.S. Food and Drug Administration (October 1996) for marketing as an EEG-based monitor of anesthetic effect is the bispectral analysis derivative known as the Bispectral Index Scale (BIS, Aspect Medical Systems, Natick, MA). The purpose of this review is to describe the clinical development of this technology and to assess our current understanding of its utility in clinical practice.Bispectral analysis is a statistical technique that allows study of phenomena with nonlinear character, such as surf beats and wave breaking. 7Bispectral analysis provides a description to a continuous pseudo–randomly varying signal (e.g. , EEG) that is an alternative to other conventional power spectral analysis techniques derived from fast Fourier transformation. The mathematics of bispectral analysis have been described elsewhere. 7–11The first studies of EEG bispectral analysis were published in 1971. 12Bispectral analysis is computationally intensive, and it was not until fast microprocessors were developed that online bispectral analysis of the EEG in the operating room became possible.Conventional analysis of the EEG using fast Fourier transformation produces information regarding the power, frequency, and the phase of the EEG signal. Typical displays, such as the compressed spectral array, graph power and frequency information and discard the phase information. 2Bispectral analysis represents a different description of the EEG in that interfrequency phase relations are measured, i.e. , the bispectrum quantifies relations among the underlying sinusoidal components of the EEG. 2Additional details regarding the computation of bispectral data can be found in Sigl and Chamoun 13and in a review by Rampil. 2The data contained in both the bispectral analysis and conventional frequency–power analyses of the EEG are used to create the proprietary parameter of the bispectral index, or BIS. 2,13BIS is a dimensionless number scaled from 100–0, with 100 representing an awake EEG and zero representing complete electrical silence (cortical suppression). During development, BIS went through several revisions (table 1) and the currently available versions (versions 3.3 and 3.4) are scaled as shown in figure 1. The BIS integrates various EEG descriptors into a single variable. The mixture of subparameters of EEG activity was derived empirically from a prospectively collected database of anesthetized volunteers with measures of clinically relevant sedative endpoints and hypnotic drug concentrations. 14The process by which BIS was derived is shown schematically in figure 2. The EEG was recorded onto a computer and was time-matched with clinical endpoints and, where available, drug concentrations. The raw EEG data were inspected, sections containing artifact were rejected, and spectral calculations were then performed to produce both bispectral and power spectral variables. Following statistical ranking, the variables correlating best with the clinical endpoint were chosen. These were then fitted to a multivariate statistical model using the maximum likelihood solution to a logistic regression analysis to produce a continuous series of BIS values. This index was then tested offline in a prospective manner on a new database, and studies evaluated its clinical utility. The parameters used in the current implementations of BIS have been detailed by Rampil. 2The BIS monitor represents the successful effort to model EEG versus behavioral responses. The BIS algorithm uses various derivatives from conventional EEG power spectral analysis as well as elements of bispectral analysis.In the absence of a gold standard for determining anesthetic depth, initial clinic
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Bispectrum estimation: A digital signal processing framework
Nikias, C. L., & Raghuveer, M. R. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13824 · Cited by 1,377
Validity and Reliability of the Observer??s: Assessment of Alertness/Sedation Scale
CHERNIK, D. A., GILLINGS, D., LAINE, H., HENDLER, J., SILVER, J. M., DAVIDSON, A. B., SCHWAM, E. M., & SIEGEL, J. L. (1990) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-199008000-00003 · Cited by 1,246
An introduction to bispectral analysis for the electroencephalogram
Sigl, J. C., & Chamoun, N. G. (1994) · Journal of Clinical Monitoring · doi:10.1007/bf01618421 · Cited by 804
Gan, T. J., Glass, P. S. A., Windsor, A. C. J., Payne, F. C., Rosow, C. E., Sebel, P. S., & Manberg, P. J. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00014 · Cited by 691
Self-citationAnesthetic Potency (MAC) Is Independent of Forebrain Structures in the Rat
Rampil, I. J., Mason, P., & Singh, H. (1993) · Anesthesiology · doi:10.1097/00000542-199304000-00014 · Cited by 521
An Introduction to Polyspectra
Brillinger, D. R. (1965) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177699896 · Cited by 513
Exaggerated Anesthetic Requirements in the Preferentially Anesthetized Brain
Antognini, J. F., & Schwartz, K. (1993) · Anesthesiology · doi:10.1097/00000542-199312000-00015 · Cited by 506
Liu, J., Singh, H., & White, P. F. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00033 · Cited by 432
A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199704000-00035 · Cited by 422
Self-citation
Cited by
Ely, E. W., Truman, B., Shintani, A., Thomason, J. W. W., Wheeler, A. P., Gordon, S., Francis, J., Speroff, T., Gautam, S., Margolin, R., et al. (2003) · JAMA · doi:10.1001/jama.289.22.2983 · Cited by 1,707
The Incidence of Awareness During Anesthesia: A Multicenter United States Study
Sebel, P. S., Bowdle, T. A., Ghoneim, M. M., Rampil, I. J., Padilla, R. E., Gan, T. J., & Domino, K. B. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000130261.90896.6c · Cited by 722
Self-citationSmith, H. A. B., Besunder, J. B., Betters, K. A., Johnson, P. N., Srinivasan, V., Stormorken, A., Farrington, E., Golianu, B., Godshall, A. J., Acinelli, L., et al. (2022) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002873 · Cited by 505
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Self-citationVivien, B., Di Maria, S., Ouattara, A., Langeron, O., Coriat, P., & Riou, B. (2003) · Anesthesiology · doi:10.1097/00000542-200307000-00006 · Cited by 292
Metadata
- Authors
- Johansen, J. W., Sebel, P. S., & Fisher, D. M.
- Venue
- Anesthesiology
- Published
- 2000-11-01
- Volume
- 93
- Issue
- 5
- Pages
- 1336-1344
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2040327687
- Cited by
- 599
- References
- 41
- FWCI
- 30.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and Clinical Application of Electroencephalographic Bispectrum Monitoring. https://app.cochat.ai/papers/10.1097/00000542-200011000-00029
- The paper
- Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000). Development and Clinical Application of Electroencephalographic Bispectrum Monitoring. Anesthesiology. https://doi.org/10.1097/00000542-200011000-00029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.