The DOI matches its Crossref record.
Ionic and Capacitive Artificial Muscle for Biomimetic Soft Robotics
Abstract
We report here the development of an actuator with an ionic electromechanically active polymer (IEAP) laminate that is exclusively designed to exhibit a combination of high electrically induced strain and high bending modulus. The newly constructed laminate is one of the few IEAPs meeting the requirements for use in miniature soft robotics. The laminate has activated carbon‐based electrodes and ionic liquid is used as an electrolyte. Layers of compliant gold foil are used as current collectors. The superior performance of the IEAP laminate is demonstrated by constructing a centimeter‐scale robot propelled by a single IEAP actuator. The cyclic locomotion of the robot is inspired by the movements of an inchworm, while the IEAP laminate is used concurrently as an actuator and a structural member. The 830‐mg robot is able to crawl on a smooth surface in open air, solely by undulation of its body. The microprocessor‐controlled robot has an on‐board lithium battery and uses a pulse‐width‐modulated signal to drive the IEAP actuator. The robot is able to carry its own power supply and even an extra payload. The constructed biomimetic robot is distinctive for the use of a non‐planar actuator whose shape is programmed during the manufacturing process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Ji, X., Liu, X., Cacucciolo, V., Imboden, M., Civet, Y., El Haitami, A., Cantin, S., Perriard, Y., & Shea, H. (2019) · Science Robotics · doi:10.1126/scirobotics.aaz6451 · Cited by 545
Supercapacitors for renewable energy applications: A review
Zhang, J., Gu, M., & Chen, X. (2023) · Micro and Nano Engineering · doi:10.1016/j.mne.2023.100229 · Cited by 483
Soft Ultrathin Electronics Innervated Adaptive Fully Soft Robots
Wang, C., Sim, K., Chen, J., Kim, H., Rao, Z., Li, Y., Chen, W., Song, J., Verduzco, R., & Yu, C. (2018) · Advanced Materials · doi:10.1002/adma.201706695 · Cited by 436
Materials, Actuators, and Sensors for Soft Bioinspired Robots
Ilami, M., Bagheri, H., Ahmed, R., Skowronek, E. O., & Marvi, H. (2021) · Advanced Materials · doi:10.1002/adma.202003139 · Cited by 435
Metadata
- Authors
- Must, I., Kaasik, F., Põldsalu, I., Mihkels, L., Johanson, U., Punning, A., & Aabloo, A.
- Venue
- Advanced Engineering Materials
- Publisher
- Wiley
- Published
- 2014-07-04
- Volume
- 17
- Issue
- 1
- Pages
- 84-94
- ISSN
- 1438-1656 (ISSN-L)
- 1527-2648
- OpenAlex
- W1580497341
- Cited by
- 176
- References
- 0
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic and Capacitive Artificial Muscle for Biomimetic Soft Robotics. https://app.cochat.ai/papers/10.1002/adem.201400246
- The paper
- Must, I., Kaasik, F., Põldsalu, I., Mihkels, L., Johanson, U., Punning, A., & Aabloo, A. (2015). Ionic and Capacitive Artificial Muscle for Biomimetic Soft Robotics. Advanced Engineering Materials. https://doi.org/10.1002/adem.201400246
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.