The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ni‐GaIn Amalgams Enabled Rapid and Customizable Fabrication of Wearable and Wireless Healthcare Electronics
Abstract
Recent advances in functional low‐melting liquid metals (LMs) provide routes to quickly fabricate wearable devices, which can offer excellent mechanical compliance on human skin compared to conventional rigid wafer‐based electronics. Particularly, the Gallium‐based LM mixtures are promising materials for use as stretchable and flexible circuits in wearable healthcare electronics due to their fantastic electrical conductivity, favorable fluidity, super compliance, and benign biocompatibility. Here, the authors develop a kind of directly‐printed Ni‐GaIn functional amalgams, which can efficiently construct wearable healthcare monitors. Unlike EGaIn, Ni‐GaIn amalgam owns a tunable and enhanced adhesion, which makes it easy to directly paint on various substrate for customized circuits. A wireless power transfer coil printed with these amalgams is presented to demonstrate the electrical stability under different tensile states. Finally, the authors design a wearable healthcare monitor for pulse wave measurement via collecting pulse wave signals from the wrist steadily. With the advantages of stretchability and rapid manufacture, the functional Ni‐GaIn amalgams as currently presented shows a promising approach for individualized wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Cited by
Power generation for wearable systems
Gao, M., Wang, P., Jiang, L., Wang, B., Yao, Y., Liu, S., Chu, D., Cheng, W., & Lu, Y. (2021) · Energy & Environmental Science · doi:10.1039/d0ee03911j · Cited by 343
Liquid Metal‐Based Soft Electronics for Wearable Healthcare
Park, Y., Lee, G., Jang, J., Yun, S. M., Kim, E., & Park, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002280 · Cited by 258
Liquid Metal Based Soft Robotics: Materials, Designs, and Applications
Wang, X., Guo, R., & Liu, J. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800549 · Cited by 255
Self-citation
Metadata
- Authors
- Guo, R., Wang, X., Chang, H., Yu, W., Liang, S., Rao, W., & Liu, J.
- Venue
- Advanced Engineering Materials
- Publisher
- Wiley
- Published
- 2018-03-15
- Volume
- 20
- Issue
- 10
- ISSN
- 1438-1656 (ISSN-L)
- 1527-2648
- OpenAlex
- W2790422080
- Cited by
- 159
- References
- 2
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ni‐GaIn Amalgams Enabled Rapid and Customizable Fabrication of Wearable and Wireless Healthcare Electronics. https://app.cochat.ai/papers/10.1002/adem.201800054
- The paper
- Guo, R., Wang, X., Chang, H., Yu, W., Liang, S., Rao, W., & Liu, J. (2018). Ni‐GaIn Amalgams Enabled Rapid and Customizable Fabrication of Wearable and Wireless Healthcare Electronics. Advanced Engineering Materials. https://doi.org/10.1002/adem.201800054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.