Epidermal Electronics

Open access
Kim, Dae-Hyeong, Lu, Nanshu, Ma, Rui, Kim, Yun-Soung, Kim, Rak-Hwan, Wang, Shuodao, Wu, Jian, Won, Sang Min +17 more·2011·Science

Abstract

Electronic systems with physical properties matched to the human epidermis can be used in clinical monitoring.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/science.1206157

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wearable sensor technologies are essential for personalized medicine through continuous monitoring of an individual's health.

    “Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health1–12.”

    From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [1]

    The paper’s Abstract describes skin-integrated sensors for physiological-status monitoring, and its ECG, EMG and EEG demonstrations show that they can measure an individual’s signals. It does not establish that wearable sensors are essential to personalized medicine or demonstrate continuous health monitoring; it notes that long-term use requires further work (Abstract; page unavailable). (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • The RAM did not have significant signal drift post 1000 stretching cycles at ≈30% strain.

    “The RAM did not have significant signal drift post 1000 stretching cycles at ≈30% strain.”

    From Wearables in Medicine (2018) · cites this paper as [19]

    The Additional information section (page not specified) reports no resistance degradation in filamentary-serpentine electrodes after 1,000 stretching cycles at 30% tensile strain. It does not identify the tested device as a RAM or report drift in a RAM signal, so those parts of the claim are unsupported. (LLM, conf=0.85)

    Experimental — accuracy not yet measured
  • The sensors were used to monitor the tension and compression cycles on a wrist for potential application in detecting tremor frequencies in Parkinson's disease and epilepsy.

    “The sensors were used to monitor the tension and compression cycles on a wrist for potential application in detecting tremor frequencies in Parkinson's disease and epilepsy.19”

    From Wearables in Medicine (2018) · cites this paper as [19]

    The figure material in the S12 section describes devices on a wrist remaining attached as skin is stretched or wrinkled, and the Additional information describes a strain gauge tested under tensile strain. Neither passage reports monitoring tension–compression cycles on a wrist or proposes detecting tremor frequencies in Parkinson’s disease or epilepsy. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • A wearable drug-delivery device featuring silicon nanomembrane strain sensors, a temperature sensor, a resistive random access memory (RAM) array, and electroresistive heaters has been developed.

    “A wearable drug‐delivery device featuring silicon nanomembrane strain sensors, a temperature sensor, a resistive random access memory (RAM) array, and electroresistive heaters has been developed (Figure 2c).19”

    From Wearables in Medicine (2018) · cites this paper as [19]

    The Figure 1 caption (indexed under S12; page unavailable) describes a skin-worn electronic platform with temperature sensors and strain gauges. The paper does not describe it as a drug-delivery device or report a resistive RAM array or electroresistive heaters; its concluding passage says further integration of components remains future work. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Additional advances are needed to meet the challenging requirements of the NICU, where comprehensive, continuous sensing with wireless functionality, clinical-grade measurement fidelity, and mechanical form factors that eliminate risk of harm to exceptionally fragile neonatal skin are essential.

    “Although such systems can support various types of biophysical measurements of physiological health (8–13), additional advances are needed to meet the challenging requirements of the NICU, where comprehensive, continuous sensing with wireless functionality, clinical-grade measurement fidelity, and mechanical form factors that eliminate risk of harm to exceptionally fragile neonatal skin are essent”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 31

  1. H. Berger, Arch Psychiatr Nervenkr 87, 527 (1929).
  2. C. Hardyck, L. Petrinovich, D. Elsworth, Science 154, 1467 (1966).
  3. E. J. Fox, R. Melzack, Pain 2, 141 (1976).
  4. J. G. Webster, in Medical Instrumentation: Application and Design (John Wiley & Sons, Inc., New York, 2009) p. 189-240.
  5. A. Searle, L. Kirkup, Physiol. Meas. 21, 271 (2001).
  6. P. Griss, H. K. Tolvanen-Laakso, P. Meriläinen, G. Stemme, IEEE Trans. Biomed. Eng. 49, 597 (2002).
  7. L. M. Yu, F. E. H. Tay, D. G. Guo, L. Xu, K. L. Yap, Sens. Actuators A 151, 17 (2009).
  8. J. R. Ives, S. M. Mirsattari, D. Jones, Clinical Neurophysiol. 118, 1633 (2007).
  9. T. Sekitani et al., Science 321, 1468 (2008).
  10. S.C.B. Mannsfeld et al., Nat. Mater. 9, 859 (2010).
  11. K. Takei et al., Nat. Mater. 9, 821 (2010).
  12. D.-H. Kim et al., Science 320, 507 (2008).
  13. R.-H. Kim et al., Nat. Mater. 9, 929 (2010).
  14. M. Gonzalez et al., Microelectronics Reliability 48, 825 (2008).
  15. S. P. Lacour, J. Jones, S. Wagner, T. Li, Z. Suo, Proc. IEEE. 93, 1459 (2005).
  16. C. Keplinger, M. Kaltenbrunner, N. Arnold, S. Bauer, Proc. Natl. Acad. Sci. USA. 107, 4505 (2010).
  17. L. Hu et al., Nano Letters 10, 708 (2010).
  18. Kuwazuru et al., Med. Eng. Physics 30, 516 (2008).
  19. M. Geerligs, J. Biomech., In press (2011).
  20. C. Pailler-Mattei et al., Med. Eng. Phy. 30, 599 (2008).
  21. V. Arumugam, J. Biosci. 19, 307 (1994).
  22. K.-P. Wilhelm, P. Elsner, E. Berardesca, in Bioengineering of the Skin: Skin Surface Imaging and Analysis, (CRC Press, Boca Raton, 1997) p. 154.
  23. D.-H. Kim et al., Proc. Natl. Acad. Sci. USA. 105, 18675 (2008).
  24. A. Kaneko, N. Asai, T. Kanda, J. Hand Ther. 18, 421 (2005).
  25. L. Sörnmo, P. Laguna, in Bioelectrical Signal Processing in Cardiac and Neurological Applications, (Elsevier, Amsterdam, 2005) p. 337-452.
  26. J. R. Stroop, J. Experimental Psychology 18, 643 (1935).
  27. O. Spreen, E. A. Strauss, in Compendium of Neuropsychological Tests: Administration, Norms and Commentary, (Oxford University Press, New York, 2006) p. 477-499.
  28. J. W. Hutchinson, Z. Suo, Advances in Applied Mechanics 29, 63 (1992).
  29. M. A. Biot., Appl. Sci. Res. A 12, 168 (1963).
  30. H. Jiang, Y. Sun, J. A. Rogers, Y. Huang, Int. J. Solids Struct. 45, 2014 (2008).
  31. Huang et al., Langmuir 21, 8058 (2005).

Cited by

Sorted by citations

Authors
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., Yu, K. J., Kim, T.-I., Chowdhury, R., Ying, M., Xu, L., Li, M., Chung, H.-J., Keum, H., McCormick, M., Liu, P., Zhang, Y.-W., Omenetto, F. G., Huang, Y., Coleman, T., & Rogers, J. A.
Affiliations
  • University of Illinois Urbana-Champaign (US)
  • Northwestern University (US)
  • Tufts University (US)
  • Institute of High Performance Computing (SG)
Corresponding author
  • Kim, Dae-Hyeong
  • Lu, Nanshu
  • Ma, Rui
  • Rogers, John A.
Venue
Science
Published
2011-08-12
Volume
333
Issue
6044
Pages
838-843
ISSN
  • 0036-8075 (ISSN-L)
  • 1095-9203
OpenAlex
W4213360791
Cited by
4,836
References
35
Citations by year
2026: 347 · 2025: 327 · 2024: 317 · 2023: 316 · 2022: 355 · 2021: 401 · 2020: 415 · 2019: 440 · 2018: 443 · 2017: 367 · 2016: 350 · 2015: 283 · 2014: 191 · 2013: 171 · 2012: 96
FWCI
89.67
Type
journal article
Language
en
Open access
Locations
  • Science (publishedVersion)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
U.S. Department of Energy (DEFG0207ER46471, DEFG0207ER46453)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
epidermal electronics, flexible electronics, van der Waals adhesion, conformal contact, temperature sensors, strain sensors, flexible transistors, light-emitting diodes, photodetectors, solar cells, wireless power transfer, bioelectric signals
MeSH terms
Adhesiveness, Electrocardiography, Electrodes, Electrodiagnosis, Electroencephalography, Electromyography, Epidermis, Humans, Monitoring, Physiologic, Electric Power Supplies, Semiconductors, Dermis, Elastomers, Nanostructures, Elastic Modulus, Mechanical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review