The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Biomimetic Hydroxyapatite–Drug Nanocrystals as Potential Bone Substitutes with Antitumor Drug Delivery Properties
Abstract
This Full Paper investigates the adsorption and desorption of the anticancer drugs cis‐diamminedichloroplatinum(II) (CDDP, cisplatin) and the new platinum(II) complex di(ethylenediamineplatinum)medronate (DPM), as well as the clinically relevant bisphosphonate alendronate, towards two biomimetic synthetic HA nanocrystalline materials with either plate‐shaped (HAps) or needle‐shaped (HAns) morphologies and different chemico‐physical properties. The adsorption and desorption kinetics are dependent on the specific properties of the drugs and the morphology of the HA nanoparticles. Adsorption of the platinum complexes occurs with retention of the nitrogen ligands but the chloride ligands of cisplatin are displaced. Despite their opposite charges, the negatively charged alendronate bisphosphonate and the positively charged aquated cisplatin are strongly adsorbed, while the neutral DPM complex shows lower affinity towards the negatively charged apatitic surface. The data suggest that adsorption of the two platinum complexes is driven by electrostatic attractions, while interaction between the alendronate and the HA surface takes place by ligand exchange in which the two phosphonate groups of the drug molecule replace two surface phosphate groups. Significantly, adsorption of positively charged hydrolysis species of cisplatin is more favored on the phosphate‐rich HAns surface while adsorption of negatively charged alendronate is more favored on the calcium‐rich HAps surface. The latter type of short‐range electrostatic interactions also appear to dominate the desorption kinetics; consequently, drug release is greater for neutral DPM than for charged alendronate and aquated cisplatin. Moreover, while the release per unit area of charged species is the same for the two types of HAs, the release of DPM is faster from HAns, which is lower in surface calcium, than for HAps. Overall, this work demonstrates that the properties of HA nanocrystals can be modulated in such a way to produce HA/biomolecule conjugates tailored for specific therapeutic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
Higuchi, T. (1963) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600521210 · Cited by 4,884
Bisphosphonates: A review of their pharmacokinetic properties
Lin, J. H. (1996) · Bone · doi:10.1016/8756-3282(95)00445-9 · Cited by 932
Nancollas, G. H., Tang, R., Phipps, R. J., Henneman, Z., Gulde, S., Wu, W., Mangood, A., Russell, R. G. G., & Ebetino, F. H. (2006) · Bone · doi:10.1016/j.bone.2005.05.003 · Cited by 862
Bisphosphonates: from the laboratory to the clinic and back again
Russell, R. G. G., & Rogers, M. J. (1999) · Bone · doi:10.1016/s8756-3282(99)00116-7 · Cited by 840
Densification behaviour and mechanisms of synthetic hydroxyapatites
Landi, E., Tampieri, A., Celotti, G., & Sprio, S. (2000) · Journal of the European Ceramic Society · doi:10.1016/s0955-2219(00)00154-0 · Cited by 734
Hydroxyapatite nanoparticles: A review of preparation methodologies.
Ferraz, M. P., Monteiro, F. J., & Manuel, C. M. (2012) · PubMed · Cited by 389
Administration routes and delivery systems of bisphosphonates for the treatment of bone resorption
Ezra, A., & Golomb, G. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00061-2 · Cited by 244
Structural characterization of nano-sized calcium deficient apatite powders
Liou, S.-C., Chen, S.-Y., Lee, H.-Y., & Bow, J.-S. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00479-4 · Cited by 190
Barroug, A., & Glimcher, M. J. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00105-x · Cited by 169
Cited by
Nanoscale hydroxyapatite particles for bone tissue engineering
Zhou, H., & Lee, J. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.03.019 · Cited by 1,541
Munir, M. U., Salman, S., Ihsan, A., & Elsaman, T. (2022) · International Journal of Nanomedicine · doi:10.2147/ijn.s360670 · Cited by 132
“While neutral DPM released more quickly from needle-shaped HA nanoparticles than from plate-shaped nanoparticles, both charged medications released at similar rates from both types of HA nanoparticles.(129) HAs-NMs are used as favorable materials in biomedical applications due to their reasonable biocompatibility, non…”
Background
Metadata
- Authors
- Palazzo, B., Iafisco, M., Laforgia, M., Margiotta, N., Natile, G., Bianchi, C. L., Walsh, D., Mann, S., & Roveri, N.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2007-07-24
- Volume
- 17
- Issue
- 13
- Pages
- 2180-2188
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W1967637692
- Cited by
- 342
- References
- 15
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomimetic Hydroxyapatite–Drug Nanocrystals as Potential Bone Substitutes with Antitumor Drug Delivery Properties. https://app.cochat.ai/papers/10.1002/adfm.200600361
- The paper
- Palazzo, B., Iafisco, M., Laforgia, M., Margiotta, N., Natile, G., Bianchi, C. L., Walsh, D., Mann, S., & Roveri, N. (2007). Biomimetic Hydroxyapatite–Drug Nanocrystals as Potential Bone Substitutes with Antitumor Drug Delivery Properties. Advanced Functional Materials. https://doi.org/10.1002/adfm.200600361
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.