The DOI matches its Crossref record.
Hydroxyapatite crystals as a local delivery system for cisplatin: adsorption and release of cisplatin in vitro
Open accessAbstract
This study describes the characteristics of the in vitro binding and release of the anti‐tumor drug cisplatin by slurries of synthetic hydroxyapatite crystals carried out in aqueous media. The adsorption of cisplatin by slurries of hydroxyapatite and its release were found to depend significantly on the ionic composition of the aqueous media used. At a constant pH of 7.4, significantly more cisplatin is adsorbed by the hydroxyapatite crystals in the slurry from a chloride‐free phosphate buffered solution or a Tris buffered solution than from a buffered phosphate solution containing chloride ions. The amount of hydroxyapatite‐bound cisplatin desorbed into solution was also progressively increased as a function of the increasing concentration of chloride in the equilibrating solution. Very little hydroxyapatite‐bound cisplatin was released from the crystals in either a Tris or phosphate buffer. These results suggest that it is the hydrated derivatives of cisplatin which are involved in the adsorption of cisplatin by hydroxyapatite crystals. The adsorption data can be expressed as a Freundlich isotherm from which the association constant can be calculated. The rate of release of cisplatin bound to crystals of hydroxyapatite is relatively slow even at the maximum concentration of chloride ions in the phosphate buffer. Approximately 33% of the total cisplatin bound to the crystals of hydroxyapatite was released after 4.25 days. An additional 15% of the remaining cisplatin bound to the hydroxyapatite cyrstals was released after an additional equilibration with fresh buffer for two weeks (58% of the total cisplatin originally bound). These findings suggest that cisplatin bound to slurries of hydroxyapatite crystals may be useful in the local treatment of malignant tumors. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Palazzo, B., Iafisco, M., Laforgia, M., Margiotta, N., Natile, G., Bianchi, C. L., Walsh, D., Mann, S., & Roveri, N. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200600361 · Cited by 342
Tseng, C.-L., Chen, J.-C., Wu, Y.-C., Fang, H.-W., Lin, F.-H., & Tang, T.-P. (2015) · Journal of Biomaterials Applications · doi:10.1177/0885328215588307 · Cited by 19
Metadata
- Authors
- Barroug, A., & Glimcher, M. J.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2002-03
- Volume
- 20
- Issue
- 2
- Pages
- 274-280
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2046558595
- Cited by
- 169
- References
- 0
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydroxyapatite crystals as a local delivery system for cisplatin: adsorption and release of cisplatin in vitro. https://app.cochat.ai/papers/10.1016/s0736-0266(01)00105-x
- The paper
- Barroug, A., & Glimcher, M. J. (2002). Hydroxyapatite crystals as a local delivery system for cisplatin: adsorption and release of cisplatin in vitro. Journal of Orthopaedic Research. https://doi.org/10.1016/s0736-0266(01)00105-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.