Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record.

A Novel Cross‐linked Poly(vinyl alcohol) (PVA) for Vascular Grafts

Chaouat, Marc, Le Visage, Catherine, Baille, Wilms E., Escoubet, Brigitte, Chaubet, Frédéric, Mateescu, Mircea Alexandru, Letourneur, Didier·2008·Advanced Functional Materials

Abstract

Poly(vinyl alcohol) (PVA) is a water‐soluble synthetic polymer with excellent film‐forming, emulsifying, and adhesive properties. The aim of this study is to design a simple process for PVA cross‐linking with sodium trimetaphosphate to form membrane devices suitable for biomedical applications. This procedure requires no organic solvent, nor melting process to obtain films with high mechanical strength. Fabrication of a small diameter tube from a PVA film is easy with a single wrapping step around a Teflon rod. Dynamic mechanical analysis demonstrated that, upon removal of the applied stress, the PVA film with a Young's modulus of 2 × 10 5 kPa returns to its original size and shape. The wall thickness of PVA tubes is 344 ± 13 µm (n = 12), which is close to the wall thickness of a human artery (350–710 µm). Suture retention of a PVA tube is excellent (140 ± 11 g), close to that of human vessels. The burst pressure of PVA tubes is found to be 507 ± 25 mm Hg, more than three times higher than the human healthy systolic arterial pressure. Under arterial pressure, there was no leakage even after needle puncture, contrary to clinical vascular expanded polytetrafluoroethylene prostheses. Finally, PVA tubes of 2 mm in diameter are used to replace a segment of an infrarenal aorta in rats. For at least one week, no mechanical nor thrombotic complications are noticed even in the absence of anticoagulant or antiplatelet treatment. Graft patency is also evidenced with non‐invasive imaging techniques. As a conclusion, this novel cross‐linking method confers to poly(vinyl alcohol) particular mechanical properties such as compliance, elasticity and resistance to mechanical stress, compatible with the circulatory blood flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.200701261

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Chaouat, M., Le Visage, C., Baille, W. E., Escoubet, B., Chaubet, F., Mateescu, M. A., & Letourneur, D.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2008-10-06
Volume
18
Issue
19
Pages
2855-2861
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2075084573
Cited by
204
References
0
FWCI
0.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Cross‐linked Poly(vinyl alcohol) (PVA) for Vascular Grafts. https://app.cochat.ai/papers/10.1002/adfm.200701261
The paper
Chaouat, M., Le Visage, C., Baille, W. E., Escoubet, B., Chaubet, F., Mateescu, M. A., & Letourneur, D. (2008). A Novel Cross‐linked Poly(vinyl alcohol) (PVA) for Vascular Grafts. Advanced Functional Materials. https://doi.org/10.1002/adfm.200701261

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.