The DOI matches its Crossref record.
Tailor‐made Polymeric Membranes based on Segmented Block Copolymers for CO2 Separation
Abstract
This paper reports the design of a tailor made polymeric membrane by using poly(ethylene oxide)–poly(butylene terephthalate) (PEO‐PBT) multi‐block copolymers. Their properties are controlled by the fraction of the PEO phase and its molecular weight. To explain the effect of structural changes in copolymer membranes, transport properties of four gases (CO 2, H 2, N 2, and CH 4) are discussed. After characterization, the two best copolymers are selected in order to prepare tailor made blends by adding poly(ethylene glycol) (PEG). The best selected copolymer that contained 55 wt. % of 4000 g mol−1 PEO produced a blend with high CO 2 permeability (∼190 barrer), which is twice the permeability of the pure copolymer. At the same time, an enhancement of CO 2/H 2 selectivity is observed (∼13). These results suggest that the morphology of PEO‐PBT can be well controlled by the addition of low‐molecular‐weight PEG, and consequently the gas transport properties can be tuned.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 38
- Baker R. W., 2000, Membrane Technology and Applications, 6
- 10.1016/S1001-0742(08)60002-9 · DOI · Paper page
- 10.1016/j.polymer.2006.01.084 · DOI · Paper page
- 10.1038/nmat1295 · DOI · Paper page
- 10.1016/S1369-7021(06)71620-0 · DOI · Paper page
- 10.1016/S1369-7021(06)71621-2 · DOI
- 10.1016/j.memsci.2005.04.054 · DOI
- 10.1016/j.memsci.2006.09.022 · doi:10.1016/j.memsci.2006.09.022
- 10.1016/j.polymer.2005.02.083 · DOI · Paper page
- 10.1016/S0142-9612(99)00237-9 · doi:10.1016/s0142-9612(99)00237-9
- 10.1016/j.memsci.2005.09.025 · doi:10.1016/j.memsci.2005.09.025
- 10.1016/S0032-3861(98)00766-6 · doi:10.1016/s0032-3861(98)00766-6
- 10.1016/0376-7388(95)00133-6 · doi:10.1016/0376-7388(95)00133-6
- 10.1021/ma049847w · DOI
- 10.1016/S0032-3861(01)00453-0 · DOI · Paper page
- 10.1016/j.memsci.2007.09.023 · DOI · Paper page
- 10.1016/j.seppur.2008.01.001 · doi:10.1016/j.seppur.2008.01.001
- 10.1016/j.memsci.2003.08.031 · DOI · Paper page
- 10.1016/j.memsci.2006.05.002 · doi:10.1016/j.memsci.2006.05.002
- 10.1021/ma0714518 · doi:10.1021/ma0714518
- 10.1016/j.memsci.2005.05.010 · doi:10.1016/j.memsci.2005.05.010
- 10.1016/j.memsci.2004.08.036 · DOI · Paper page
- 10.1016/S0011-9164(02)00721-X · doi:10.1016/s0011-9164(02)00721-x
- 10.1021/jp035640d · doi:10.1021/jp035640d
- 10.1063/1.1713103 · DOI
- 10.1002/macp.1990.021910315 · doi:10.1002/macp.1990.021910315
- 10.1016/0032-3861(94)90476-6 · doi:10.1016/0032-3861(94)90476-6
- 10.1002/pola.1994.080321601 · doi:10.1002/pola.1994.080321601
- 10.1016/0376-7388(95)00301-0 · doi:10.1016/0376-7388(95)00301-0
- Koros W. J., 1987, Handbook of Separation Process, 803
- 10.1016/j.molstruc.2004.07.045 · DOI · Paper page
- 10.1126/science.1118079 · DOI · Paper page
- 10.1246/cl.1993.225 · DOI
- 10.1002/(SICI)1099-0488(19990901)37:17<2463::AID-POLB18>3.0.CO;2-H · DOI
- 10.1016/S0376-7388(01)00444-6 · DOI
- 10.1021/ma0356257 · DOI
- 10.1002/adfm.200305136 · DOI
- 10.1016/j.polymer.2005.09.067 · DOI
Cited by
Gas Separation Membrane Materials: A Perspective
Baker, R. W., & Low, B. T. (2014) · Macromolecules · doi:10.1021/ma501488s · Cited by 1,203
Zeolitic imidazolate framework (ZIF-8) based polymer nanocomposite membranes for gas separation
Song, Q., Nataraj, S. K., Roussenova, M. V., Tan, J. C., Hughes, D. J., Li, W., Bourgoin, P., Alam, M. A., Cheetham, A. K., Al-Muhtaseb, S. A., et al. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21996d · Cited by 744
Abanades, J. C., Arias, B., Lyngfelt, A., Mattisson, T., Wiley, D. E., Li, H., Ho, M. T., Mangano, E., & Brandani, S. (2015) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2015.04.018 · Cited by 441
PVAm–PIP/PS Composite Membrane with High Performance for CO2/N2 Separation
Qiao, Z., Wang, Z., Zhang, C., Yuan, S., Zhu, Y., Wang, J., & Wang, S. (2013) · AIChE Journal · doi:10.1002/aic.13781 · Cited by 398
Xie, K., Fu, Q., Qiao, G. G., & Webley, P. A. (2019) · Journal of Membrane Science · doi:10.1016/j.memsci.2018.10.049 · Cited by 308
Metadata
- Authors
- Car, A., Stropnik, C., Yave, W., & Peinemann, K.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2008-09-16
- Volume
- 18
- Issue
- 18
- Pages
- 2815-2823
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2160730391
- Cited by
- 261
- References
- 0
- FWCI
- 27.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tailor‐made Polymeric Membranes based on Segmented Block Copolymers for CO2 Separation. https://app.cochat.ai/papers/10.1002/adfm.200800436
- The paper
- Car, A., Stropnik, C., Yave, W., & Peinemann, K. (2008). Tailor‐made Polymeric Membranes based on Segmented Block Copolymers for CO2 Separation. Advanced Functional Materials. https://doi.org/10.1002/adfm.200800436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.