The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Selective Zinc(II)‐Ion Fluorescence Sensing by a Functionalized Mesoporous Material Covalently Grafted with a Fluorescent Chromophore and Consequent Biological Applications
Abstract
A highly ordered 2D‐hexagonal mesoporous silica material is functionalized with 3‐aminopropyltriethoxysilane. This organically modified mesoporous material is grafted with a dialdehyde fluorescent chromophore, 4‐methyl‐2,6‐diformyl phenol. Powder X‐ray diffraction, transmission electron microscopy, N 2 sorption, Fourier transform infrared spectroscopy, and UV‐visible absorption and emission have been employed to characterize the material. This material shows excellent selective Zn 2+ sensing, which is due to the fluorophore moiety present at its surface. Fluorescence measurements reveal that the emission intensity of the Zn 2+‐bound mesoporous material increases significantly upon addition of various concentrations of Zn 2+, while the introduction of other biologically relevant (Ca 2+, Mg 2+, Na+, and K+) and environmentally hazardous transition‐metal ions results in either unchanged or weakened intensity. The enhancement of fluorescence is attributed to the strong covalent binding of Zn 2+, evident from the large binding constant value (0.87 × 10 4 M−1). Thus, this functionalized mesoporous material grafted with the fluorescent chromophore could monitor or recognize Zn 2+ from a mixture of ions that contains Zn 2+ even in trace amounts and can be considered as a selective fluorescent probe. We have examined the application of this mesoporous zinc(II) sensor to cultured living cells (A375 human melanoma and human cervical cancer cell, HeLa) by fluorescence microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mesoporous silica nanoparticles for drug delivery and biosensing applications
Slowing, I. I., Trewyn, B. G., Giri, S., & Lin, V. S. ‐. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601191 · Cited by 1,699
Bush, A. (2000) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(99)00073-3 · Cited by 731
Cited by
Recent progress on polymer-based fluorescent and colorimetric chemosensors
Kim, H. N., Guo, Z., Zhu, W., Yoon, J., & Tian, H. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00058b · Cited by 959
Kayal, U., Mohanty, B., Bhanja, P., Chatterjee, S., Chandra, D., Hara, M., Kumar Jena, B., & Bhaumik, A. (2019) · Dalton Transactions · doi:10.1039/c8dt04159h · Cited by 48
Self-citation
Metadata
- Authors
- Sarkar, K., Dhara, K., Nandi, M., Roy, P., Bhaumik, A., & Banerjee, P.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2009-01-08
- Volume
- 19
- Issue
- 2
- Pages
- 223-234
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2086964804
- Cited by
- 208
- References
- 2
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Zinc(II)‐Ion Fluorescence Sensing by a Functionalized Mesoporous Material Covalently Grafted with a Fluorescent Chromophore and Consequent Biological Applications. https://app.cochat.ai/papers/10.1002/adfm.200800888
- The paper
- Sarkar, K., Dhara, K., Nandi, M., Roy, P., Bhaumik, A., & Banerjee, P. (2009). Selective Zinc(II)‐Ion Fluorescence Sensing by a Functionalized Mesoporous Material Covalently Grafted with a Fluorescent Chromophore and Consequent Biological Applications. Advanced Functional Materials. https://doi.org/10.1002/adfm.200800888
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.