The DOI matches its Crossref record.
Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers
Open accessAbstract
Here, the use of low‐energy metal ion implantation by filtered cathodic vacuum arc to create highly deformable electrodes on polydimethylsiloxane (PDMS) membranes is reported. Implantation leads to the creation of nanometer‐size clusters in the first 50 nm below the surface. When the elastomer is stretched, these small clusters can move relative to one another, maintaining electrical conduction at strains of up to 175%. Sheet resistance versus ion dose, resistance versus strain, time stability of the resistance, and the impact of implantation on the elastomer's Young's modulus are investigated for gold, palladium, and titanium implantations. Of the three tested metals, gold has the best performance, combining low and stable surface resistance, very high strain capabilities before loss of electrical conduction, and low impact on the Young's modulus of the PDMS membrane. These electrodes are cyclically strained to 30% for more than 10 5 cycles and remain conductive. In contrast, sputtered or evaporate metals films cease to conduct at strains of order 3%. Additionally, metal ion implantation allows for creating semi‐transparent electrodes. The optical transmission through 25‐µm‐thick PDMS membranes decreases from 90% to 60% for Pd implantations at doses used to make stretchable electrodes. The implantation technique presented here allows the rapid production of reliable stretchable electrodes for a number of applications, including dielectric elastomer actuators and foldable or rollable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Embedded 3D Printing of Strain Sensors within Highly Stretchable Elastomers
Muth, J. T., Vogt, D. M., Truby, R. L., Mengüç, Y., Kolesky, D. B., Wood, R. J., & Lewis, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201400334 · Cited by 1,611
Artificial Muscles: Mechanisms, Applications, and Challenges
Mirvakili, S. M., & Hunter, I. W. (2018) · Advanced Materials · doi:10.1002/adma.201704407 · Cited by 1,077
Materials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Flexible and stretchable electrodes for dielectric elastomer actuators
Rosset, S., & Shea, H. R. (2013) · Applied Physics A · doi:10.1007/s00339-012-7402-8 · Cited by 529
Self-citation
Metadata
- Authors
- Rosset, S., Niklaus, M., Dubois, P., & Shea, H. R.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2009-02-02
- Volume
- 19
- Issue
- 3
- Pages
- 470-478
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2117051458
- Cited by
- 200
- References
- 0
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers. https://app.cochat.ai/papers/10.1002/adfm.200801218
- The paper
- Rosset, S., Niklaus, M., Dubois, P., & Shea, H. R. (2009). Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers. Advanced Functional Materials. https://doi.org/10.1002/adfm.200801218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.