Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record.

Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers

Open access
Rosset, Samuel, Niklaus, Muhamed, Dubois, Philippe, Shea, Herbert R.·2009·Advanced Functional Materials

Abstract

Here, the use of low‐energy metal ion implantation by filtered cathodic vacuum arc to create highly deformable electrodes on polydimethylsiloxane (PDMS) membranes is reported. Implantation leads to the creation of nanometer‐size clusters in the first 50 nm below the surface. When the elastomer is stretched, these small clusters can move relative to one another, maintaining electrical conduction at strains of up to 175%. Sheet resistance versus ion dose, resistance versus strain, time stability of the resistance, and the impact of implantation on the elastomer's Young's modulus are investigated for gold, palladium, and titanium implantations. Of the three tested metals, gold has the best performance, combining low and stable surface resistance, very high strain capabilities before loss of electrical conduction, and low impact on the Young's modulus of the PDMS membrane. These electrodes are cyclically strained to 30% for more than 10 5 cycles and remain conductive. In contrast, sputtered or evaporate metals films cease to conduct at strains of order 3%. Additionally, metal ion implantation allows for creating semi‐transparent electrodes. The optical transmission through 25‐µm‐thick PDMS membranes decreases from 90% to 60% for Pd implantations at doses used to make stretchable electrodes. The implantation technique presented here allows the rapid production of reliable stretchable electrodes for a number of applications, including dielectric elastomer actuators and foldable or rollable electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.200801218

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Rosset, S., Niklaus, M., Dubois, P., & Shea, H. R.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2009-02-02
Volume
19
Issue
3
Pages
470-478
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2117051458
Cited by
200
References
0
FWCI
10.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers. https://app.cochat.ai/papers/10.1002/adfm.200801218
The paper
Rosset, S., Niklaus, M., Dubois, P., & Shea, H. R. (2009). Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers. Advanced Functional Materials. https://doi.org/10.1002/adfm.200801218

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.