The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Streptavidin‐Functionalized Silver‐Nanoparticle‐Enriched Carbon Nanotube Tag for Ultrasensitive Multiplexed Detection of Tumor Markers
Abstract
A streptavidin‐functionalized silver‐nanoparticle‐enriched carbon nanotube (CNT/Ag NP) is designed as trace tag for ultrasensitive multiplexed measurements of tumor markers using a disposable immunosensor array. The CNT/Ag NP nanohybrid is prepared by one‐pot in situ deposition of Ag NPs on carboxylated CNTs. The nanohybrid is functionalized with streptavidin via the inherent interaction between the protein and Ag NPs for further linkage of biotinylated signal antibodies to obtain tagged antibodies. The functionalization process greatly improves the dispersibility of the nanohybrid in water. The immunosensor array is prepared by covalently immobilizing capture antibodies on chitosan‐modified screen‐printed carbon electrodes. Through a sandwich‐type immunoreaction on the immunosensor array, numerous Ag NPs are captured onto every single immunocomplex and are further amplified by a subsequent Ag NP‐promoted deposition of silver from a silver enhancer solution to obtain the sensitive electrochemical‐stripping signal of the Ag NPs. Using carcinoembryonic antigen and α‐fetoprotein as model analytes, this proposed multiplexed immunoassay method shows acceptable precision and wide linear ranges over four orders of magnitude with detection limits down to 0.093 and 0.061 pg mL−1, respectively. The assay results of serum samples with the proposed method are in acceptable agreement with the reference values. The newly designed strategy and the functionalized tag avoid cross‐talk and the requirement of deoxygenation for electrochemical immunoassay, and thus provide a promising potential in clinical application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emerging molecular markers of cancer
Sidransky, D. (2002) · Nature Reviews Cancer · doi:10.1038/nrc755 · Cited by 662
Cited by
Screen-printed electrodes for biosensing: a review (2008–2013)
Taleat, Z., Khoshroo, A., & Mazloum-Ardakani, M. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1181-1 · Cited by 542
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Multiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Metadata
- Authors
- Lai, G., Wu, J., Ju, H., & Yan, F.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2011-05-26
- Volume
- 21
- Issue
- 15
- Pages
- 2938-2943
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2131744837
- Cited by
- 183
- References
- 1
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Streptavidin‐Functionalized Silver‐Nanoparticle‐Enriched Carbon Nanotube Tag for Ultrasensitive Multiplexed Detection of Tumor Markers. https://app.cochat.ai/papers/10.1002/adfm.201100396
- The paper
- Lai, G., Wu, J., Ju, H., & Yan, F. (2011). Streptavidin‐Functionalized Silver‐Nanoparticle‐Enriched Carbon Nanotube Tag for Ultrasensitive Multiplexed Detection of Tumor Markers. Advanced Functional Materials. https://doi.org/10.1002/adfm.201100396
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.