The DOI matches its Crossref record.
Novel Signal‐Amplifying Fluorescent Nanofibers for Naked‐Eye‐Based Ultrasensitive Detection of Buried Explosives and Explosive Vapors
Abstract
A novel electrospun fluorescent nanofiberous membrane with a function like “molecular wires” was developed via electrospinning for the detection of ultra‐trace nitro explosive vapors and buried explosives by naked eye under UV excitation. The high binding affinity between the electron‐deficient nitro explosives and the sensing film results in a rapid, dramatic quenching in its fluorescence emission. A wide spectrum of nitro explosives, in particular, TNT, Tetryl, RDX, PETN and HMX could be “visually” detected at their sub‐equilibrium vapors (less than 10 ppb, 74 ppt, 5 ppt, 7 ppt and 0.1 ppt, respectively) released from 1 ng explosives residues. Such outstanding sensing performance could be attributed to the proposed “sandwich‐like” conformation between pyrene and phenyl pendants of PS which may allow efficient long‐range energy migration similar to “molecular wire”, thus achieving amplified fluorescence quenching. Its application for the detection of buried explosives in soil by naked eye was also demonstrated, indicating its potential application for landmine mapping. To the best of our knowledge, this is the first report about the detection of buried explosives without the use of any advanced analytical instrumentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Highly Selective Detection of Nitro Explosives by a Luminescent Metal–Organic Framework
Nagarkar, S. S., Joarder, B., Chaudhari, A. K., Mukherjee, S., & Ghosh, S. K. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201208885 · Cited by 1,353
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Self-citationWearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Nanoparticles meet electrospinning: recent advances and future prospects
Zhang, C.-L., & Yu, S.-H. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60426h · Cited by 665
Zhang, S., Du, D., Qin, J., Bao, S., Li, S., He, W., Lan, Y., Shen, P., & Su, Z. (2014) · Chemistry – A European Journal · doi:10.1002/chem.201304692 · Cited by 288
Luminescent films for chemo- and biosensing
Guan, W., Zhou, W., Lu, J., & Lu, C. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00246j · Cited by 287
Highly Selective Detection of Nitro Explosives by a Luminescent Metal–Organic Framework
Nagarkar, S. S., Joarder, B., Chaudhari, A. K., Mukherjee, S., & Ghosh, S. K. (2013) · Angewandte Chemie · doi:10.1002/ange.201208885 · Cited by 279
Wu, X.-X., Fu, H.-R., Han, M.-L., Zhou, Z., & Ma, L.-F. (2017) · Crystal Growth & Design · doi:10.1021/acs.cgd.7b01155 · Cited by 267
Nanofiber‐Based Chemical Sensors
Andrady, A. L. (2022) · Applications of Polymer Nanofibers · doi:10.1002/9781119267713.ch4 · Cited by 5
Metadata
- Authors
- Wang, Y., La, A., Ding, Y., Liu, Y., & Lei, Y.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2012-05-11
- Volume
- 22
- Issue
- 17
- Pages
- 3547-3555
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2049886410
- Cited by
- 182
- References
- 0
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.