The DOI matches its Crossref record.
Hydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery
Open accessAbstract
Unique microneedle arrays prepared from crosslinked polymers, which contain no drug themselves, are described. They rapidly take up skin interstitial fluid upon skin insertion to form continuous, unblockable, hydrogel conduits from attached patch‐type drug reservoirs to the dermal microcirculation. Importantly, such microneedles, which can be fabricated in a wide range of patch sizes and microneedle geometries, can be easily sterilized, resist hole closure while in place, and are removed completely intact from the skin. Delivery of macromolecules is no longer limited to what can be loaded into the microneedles themselves and transdermal drug delivery is now controlled by the crosslink density of the hydrogel system rather than the stratum corneum, while electrically modulated delivery is also a unique feature. This technology has the potential to overcome the limitations of conventional microneedle designs and greatly increase the range of the type of drug that is deliverable transdermally, with ensuing benefits for industry, healthcare providers and, ultimately, patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Self-citationMussel-inspired hydrogels: From design principles to promising applications
Zhang, C., Wu, B., Zhou, Y., Zhou, F., Liu, W., & Wang, Z. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00849g · Cited by 653
Current trends in polymer microneedle for transdermal drug delivery
Ahmed Saeed AL-Japairai, K., Mahmood, S., Hamed Almurisi, S., Reddy Venugopal, J., Rebhi Hilles, A., Azmana, M., & Raman, S. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119673 · Cited by 448
Emerging micro- and nanotechnology based synthetic approaches for insulin delivery
Mo, R., Jiang, T., Di, J., Tai, W., & Gu, Z. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60436e · Cited by 386
Microneedles: A New Frontier in Nanomedicine Delivery
Larrañeta, E., McCrudden, M. T. C., Courtenay, A. J., & Donnelly, R. F. (2016) · Pharmaceutical Research · doi:10.1007/s11095-016-1885-5 · Cited by 339
Self-citation
Metadata
- Authors
- Donnelly, R. F., Singh, T. R. R., Garland, M. J., Migalska, K., Majithiya, R., McCrudden, C. M., Kole, P. L., Mahmood, T. M. T., McCarthy, H. O., & Woolfson, A. D.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2012-07-09
- Volume
- 22
- Issue
- 23
- Pages
- 4879-4890
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2143616792
- Cited by
- 727
- References
- 0
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery. https://app.cochat.ai/papers/10.1002/adfm.201200864
- The paper
- Donnelly, R. F., Singh, T. R. R., Garland, M. J., Migalska, K., Majithiya, R., McCrudden, C. M., Kole, P. L., Mahmood, T. M. T., McCarthy, H. O., & Woolfson, A. D. (2012). Hydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery. Advanced Functional Materials. https://doi.org/10.1002/adfm.201200864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.