Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record.

A Phosphorescent Nanoparticle‐Based Probe for Sensing and Imaging of (Intra)Cellular Oxygen in Multiple Detection Modalities

Kondrashina, Alina V., Dmitriev, Ruslan I., Borisov, Sergey M., Klimant, Ingo, O'Brien, Ian, Nolan, Yvonne M., Zhdanov, Alexander V., Papkovsky, Dmitri B.·2012·Advanced Functional Materials

Abstract

Monitoring cell and tissue oxygenation is important for the analysis of cell development and differentiation, mitochondrial function, and common (patho)physiological conditions such as ischemia, cancer, neurodegenerative disorders. A number of materials for sensing cellular oxygen (O 2) by optical means have been described in recent years, but the diverse range of biological models and measurement tasks demands more versatile, flexible, and simple O 2 sensors. A new cell‐penetrating phosphorescent nanosensor material called MM2 probe is presented. In it, the highly photostable phosphorescent reporter dye Pt(II)‐5,10,15,20‐tetrakis‐(2,3,4,5,6‐pentafluorophenyl)‐porphyrin (PtTFPP; emission at 650 nm) and poly(9,9‐dioctylfluorene) (PFO) fluorophore act as Förster resonance energy transfer (FRET) donor and two‐photon antennae are embedded in cationic hydrogel nanoparticles. Such probe formulation provides efficient delivery into the cell and subsequent sensing and high‐resolution imaging of cellular O 2 in different detection modalities, including ratiometric intensity and phosphorescence lifetime‐based sensing under one‐photon and two photon excitation. MM2 probe combines high brightness, photo‐ and chemical stability, low toxicity, and ease of fabrication and use. Its versatility and analytical performance are demonstrated in physiological experiments with adherent cells and neurospheres representing 2D and 3D respiring objects and detection on time‐resolved fluorescent readers, confocal and multiphoton microscopes, and customized microsecond fluorescence/phosphorescence lifetime imaging microscopy (FLIM) systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201201387

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Kondrashina, A. V., Dmitriev, R. I., Borisov, S. M., Klimant, I., O'Brien, I., Nolan, Y. M., Zhdanov, A. V., & Papkovsky, D. B.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2012-07-20
Volume
22
Issue
23
Pages
4931-4939
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2162282633
Cited by
158
References
0
FWCI
12.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Phosphorescent Nanoparticle‐Based Probe for Sensing and Imaging of (Intra)Cellular Oxygen in Multiple Detection Modalities. https://app.cochat.ai/papers/10.1002/adfm.201201387
The paper
Kondrashina, A. V., Dmitriev, R. I., Borisov, S. M., Klimant, I., O'Brien, I., Nolan, Y. M., Zhdanov, A. V., & Papkovsky, D. B. (2012). A Phosphorescent Nanoparticle‐Based Probe for Sensing and Imaging of (Intra)Cellular Oxygen in Multiple Detection Modalities. Advanced Functional Materials. https://doi.org/10.1002/adfm.201201387

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.