The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nanomaterial‐Based Fluorescent DNA Analysis: A Comparative Study of the Quenching Effects of Graphene Oxide, Carbon Nanotubes, and Gold Nanoparticles
Abstract
A variety of nanomaterials have shown extraordinarily high quenching ability toward a broad range of fluorophores. Recently, there has been intense interest in developing new tools for fluorescent DNA analysis in solution or inside the cell based on this property, and by exploiting interactions between these nanoscale “superquenchers” and DNA molecules in the single‐stranded (ss‐) or double‐stranded (ds‐) forms. Here, a comparative study on the nanoqueching effects is performed by using a series of nanomaterials with different dimensions, i.e., gold nanoparticles (AuNPs, 0D), carbon nanotubes (CNTs, 1D), and graphene oxide (GO, 2D). The quenching efficiency, kinetics, differentiation ability, and influencing factors such as concentration and ionic strength are studied. Interestingly, GO exhibits superior quenching abilities to the other two materials in both the quenching efficiency and kinetics. As a result, a GO‐based fluorescent sensor, designed in a simple mix‐and‐detect format, can detect concentrations of DNA as low as 0.2 n M, which is better than either CNTs or AuNPs by an order of magnitude. This sensor can also differentiate single‐base mismatches much better than either CNTs‐ or AuNPs‐ based sensors. This study paves the way to better choice of nanomaterials for bioanalysis and elaborate design of biosensors for both in vitro diagnosis and in vivo bioimaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Cited by
Fluorescent biosensors enabled by graphene and graphene oxide
Zhang, H., Zhang, H., Aldalbahi, A., Zuo, X., Fan, C., & Mi, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.07.030 · Cited by 264
Self-citationBioinspired polydopamine nanospheres: a superquencher for fluorescence sensing of biomolecules
Qiang, W., Li, W., Li, X., Chen, X., & Xu, D. (2014) · Chem. Sci. · doi:10.1039/c4sc00085d · Cited by 257
Metadata
- Authors
- Li, F., Pei, H., Wang, L., Lu, J., Gao, J., Jiang, B., Zhao, X., & Fan, C.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2013-03-22
- Volume
- 23
- Issue
- 33
- Pages
- 4140-4148
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2054865183
- Cited by
- 192
- References
- 1
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanomaterial‐Based Fluorescent DNA Analysis: A Comparative Study of the Quenching Effects of Graphene Oxide, Carbon Nanotubes, and Gold Nanoparticles. https://app.cochat.ai/papers/10.1002/adfm.201203816
- The paper
- Li, F., Pei, H., Wang, L., Lu, J., Gao, J., Jiang, B., Zhao, X., & Fan, C. (2013). Nanomaterial‐Based Fluorescent DNA Analysis: A Comparative Study of the Quenching Effects of Graphene Oxide, Carbon Nanotubes, and Gold Nanoparticles. Advanced Functional Materials. https://doi.org/10.1002/adfm.201203816
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.