The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Enhanced Performance of a ZnO Nanowire‐Based Self‐Powered Glucose Sensor by Piezotronic Effect
Abstract
A self‐powered, piezotronic effect‐enhanced glucose sensor based on metal‐semiconductor‐metal (M–S–M) structured single ZnO nanowire device is demonstrated. A triboelectrical nanogenerator (TENG) is integrated to build a self‐powered glucose monitoring system (GMS) to realize the continuously monitoring of glucose concentrations. The performance of the glucose sensor is generally enhanced by the piezotronic effect when applying a –0.79% compressive strain on the device, and magnitude of the output signal is increased by more than 200%; the sensing resolution and sensitivity of sensors are improved by more than 200% and 300%, respectively. A theoretical model using energy band diagram is proposed to explain the observed results. This work demonstrates a promising approach to raise the sensitivity, improve the sensing resolution, and generally enhance the performance of glucose sensors, also providing a possible way to build up a self‐powered GMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Cited by
Recent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
Self-citationPiezotronics and piezo-phototronics for adaptive electronics and optoelectronics
Wu, W., & Wang, Z. L. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.31 · Cited by 656
Self-citationLiu, H., Chen, X., Zheng, Y., Zhang, D., Zhao, Y., Wang, C., Pan, C., Liu, C., & Shen, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008006 · Cited by 625
Self-citationSelf‐Powered Nanoscale Photodetectors
Tian, W., Wang, Y., Chen, L., & Li, L. (2017) · Small · doi:10.1002/smll.201701848 · Cited by 377
Piezotronics and Piezo-phototronics of Third Generation Semiconductor Nanowires
Pan, C., Zhai, J., & Wang, Z. L. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00599 · Cited by 351
Self-citation
Metadata
- Authors
- Yu, R., Pan, C., Chen, J., Zhu, G., & Wang, Z. L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2013-07
- Volume
- 23
- Issue
- 47
- Pages
- 5868-5874
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2013571151
- Cited by
- 199
- References
- 2
- FWCI
- 12.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Performance of a ZnO Nanowire‐Based Self‐Powered Glucose Sensor by Piezotronic Effect. https://app.cochat.ai/papers/10.1002/adfm.201300593
- The paper
- Yu, R., Pan, C., Chen, J., Zhu, G., & Wang, Z. L. (2013). Enhanced Performance of a ZnO Nanowire‐Based Self‐Powered Glucose Sensor by Piezotronic Effect. Advanced Functional Materials. https://doi.org/10.1002/adfm.201300593
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.