Highly Sensitive Non‐Classical Strain Gauge Using Organic Heptazole Thin‐Film Transistor Circuit on a Flexible Substrate
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A non‐classical organic strain gauge as a voltage signal sensor is reported, using an inverter‐type thin‐film transistor (TFT) circuit, which is able to sensitively measure a large quantity of elastic strain (up to ≈2.48%), which approaches an almost folding state. Novel heptazole‐based organic TFTs are chosen to be incorporated in this gauge circuit; organic solid heptazole has small domain size in general. While large crystal domain‐pentacene TFTs seldom show sufficient current variation upon mechanical bending for tensile strain, these heptazole TFTs demonstrate a significant variation for the same strain condition as applied to pentacene devices. In addition, the pentacene channel does not recover to its original electric state after bending but heptazole channels are very elastic and reversible, even after going through serious bending. More interesting is that the heptazole TFTs show only a little variation of signal current under horizontal direction strain, while they make a significant amount of current decrease under vertical direction strain. Utilizing the anisotropic response to the tensile bending strain, an ultrasensitive voltage output strain gauge composed of a horizontally and vertically oriented TFT couple is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Flexible organic transistors and circuits with extreme bending stability
Sekitani, T., Zschieschang, U., Klauk, H., & Someya, T. (2010) · Nature Materials · doi:10.1038/nmat2896 · Cited by 1,253
Organic Nonvolatile Memory Transistors for Flexible Sensor Arrays
Sekitani, T., Yokota, T., Zschieschang, U., Klauk, H., Bauer, S., Takeuchi, K., Takamiya, M., Sakurai, T., & Someya, T. (2009) · Science · doi:10.1126/science.1179963 · Cited by 962
Cited by
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Recent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
Organic crystalline materials in flexible electronics
Wang, Y., Sun, L., Wang, C., Yang, F., Ren, X., Zhang, X., Dong, H., & Hu, W. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00406d · Cited by 434
Metadata
- Authors
- Nam, S. H., Jeon, P. J., Min, S. W., Lee, Y. T., Park, E. Y., & Im, S.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2014-04-06
- Volume
- 24
- Issue
- 28
- Pages
- 4413-4419
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W1965085030
- Cited by
- 49
- References
- 4
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Non‐Classical Strain Gauge Using Organic Heptazole Thin‐Film Transistor Circuit on a Flexible Substrate. https://app.cochat.ai/papers/10.1002/adfm.201400139
- The paper
- Nam, S. H., Jeon, P. J., Min, S. W., Lee, Y. T., Park, E. Y., & Im, S. (2014). Highly Sensitive Non‐Classical Strain Gauge Using Organic Heptazole Thin‐Film Transistor Circuit on a Flexible Substrate. Advanced Functional Materials. https://doi.org/10.1002/adfm.201400139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.