Bio‐Inspired All‐Organic Soft Actuator Based on a π–π Stacked 3D Ionic Network Membrane and Ultra‐Fast Solution Processing
The DOI matches its Crossref record.
Abstract
Next generation electronic products, such as wearable electronics, flexible displays, and smart mobile phones, will require the use of unprecedented electroactive soft actuators for haptic and stimuli‐responsive devices and space‐saving bio‐mimetic actuation. Here, a bio‐inspired all‐organic soft actuator with a π–π stacked and 3D ionic networked membrane based on naphthalene‐tetracarboxylic dianhydride (Ntda) and sulfonated polyimide block copolymers (SPI) is presented, utilizing an ultra‐fast solution process. The π–π stacked and self‐assembled 3D ionic networked membrane with continuous and interconnected ion transport nanochannels is synthesized by introducing simple and strong atomic level regio‐specific interactions of hydrophilic and hydrophobic SPI co‐blocks with cations and anions in the ionic liquid. Furthermore, a facile and ultrafast all‐solution process involving solvent blending, dry casting, and solvent dropping is developed to produce electro‐active soft actuators with highly conductive polyethylenedioxythiophene (PEDOT):polystyrenesulfonate (PSS) electrodes. Ionic conductivity and ion exchange capacity of the π–π stacked Ntda‐SPI membrane can be increased up to 3.1 times and 3.4 times of conventional SPI, respectively, resulting in a 3.2 times larger bending actuation. The developed bio‐inspired soft actuator is a good candidate for satisfying the tight requirements of next generation soft electronic devices due to its key benefits such as low operating voltage and comparatively large strains, as well as quick response and facile processability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Field responsive materials: photo-, electro-, magnetic- and ultrasound-sensitive polymers
Manouras, T., & Vamvakaki, M. (2017) · Polymer Chemistry · doi:10.1039/c6py01455k · Cited by 329
Ma, S., Zhang, Y., Liang, Y., Ren, L., Tian, W., & Ren, L. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908508 · Cited by 256
Sulfur and Nitrogen Co‐Doped Graphene Electrodes for High‐Performance Ionic Artificial Muscles
Kotal, M., Kim, J., Kim, K. J., & Oh, I. (2016) · Advanced Materials · doi:10.1002/adma.201505243 · Cited by 210
Self-citationReview of Soft Actuator Materials
Kim, J., Kim, J. W., Kim, H. C., Zhai, L., Ko, H.-U., & Muthoka, R. M. (2019) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-019-00255-1 · Cited by 208
Metadata
- Authors
- Cheedarala, R. K., Jeon, J., Kee, C., & Oh, I.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2014-07-25
- Volume
- 24
- Issue
- 38
- Pages
- 6005-6015
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W1999973812
- Cited by
- 86
- References
- 0
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bio‐Inspired All‐Organic Soft Actuator Based on a π–π Stacked 3D Ionic Network Membrane and Ultra‐Fast Solution Processing. https://app.cochat.ai/papers/10.1002/adfm.201401136
- The paper
- Cheedarala, R. K., Jeon, J., Kee, C., & Oh, I. (2014). Bio‐Inspired All‐Organic Soft Actuator Based on a π–π Stacked 3D Ionic Network Membrane and Ultra‐Fast Solution Processing. Advanced Functional Materials. https://doi.org/10.1002/adfm.201401136
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.