The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Helical 3D‐Printed Metal Electrodes as Custom‐Shaped 3D Platform for Electrochemical Devices
Abstract
3D‐printing represents an emerging technology that can revolutionize the way object and functional devices are fabricated. Here the use of metal 3D printing is demonstrated to fabricate bespoke electrochemical stainless steel electrodes that can be used as platform for different electrochemical applications ranging from electrochemical capacitors, oxygen evolution catalyst, and pH sensor by means of an effective and controlled deposition of IrO 2 films. The electrodes have been characterized by scanning electrode microscopy and energy dispersive X‐ray spectroscopy before the electrochemical testing. Excellent pseudocapacitive as well as catalytic properties have been achieved with these 3D printed steel‐IrO 2 electrodes in alkaline solutions. These electrodes also demonstrate Nernstian behavior as pH sensor. This work represents a breakthrough in on‐site prototyping and fabrication of highly tailored electrochemical devices with complex 3D shapes which facilitate specific functions and properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of 3D Printing and Its Potential Impact on Biotechnology and the Chemical Sciences
Gross, B. C., Erkal, J. L., Lockwood, S. Y., Chen, C., & Spence, D. M. (2014) · Analytical Chemistry · doi:10.1021/ac403397r · Cited by 1,746
Improved Electrodeposited Iridium Oxide pH Sensor Fabricated on Etched Titanium Substrates
Marzouk, S. A. M. (2003) · Analytical Chemistry · doi:10.1021/ac0261404 · Cited by 136
Cited by
Fundamentals and applications of 3D printing for novel materials
Lee, J.-Y., An, J., & Chua, C. K. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.02.004 · Cited by 1,354
3D-printing technologies for electrochemical applications
Ambrosi, A., & Pumera, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00714c · Cited by 1,040
Self-citationSmart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Additive manufacturing of structural materials
Liu, G., Zhang, X., Chen, X., He, Y., Cheng, L., Huo, M., Yin, J., Hao, F., Chen, S., Wang, P., et al. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100596 · Cited by 707
Metadata
- Authors
- Ambrosi, A., Moo, J. G. S., & Pumera, M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2015-12-15
- Volume
- 26
- Issue
- 5
- Pages
- 698-703
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2291919207
- Cited by
- 214
- References
- 2
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Helical 3D‐Printed Metal Electrodes as Custom‐Shaped 3D Platform for Electrochemical Devices. https://app.cochat.ai/papers/10.1002/adfm.201503902
- The paper
- Ambrosi, A., Moo, J. G. S., & Pumera, M. (2016). Helical 3D‐Printed Metal Electrodes as Custom‐Shaped 3D Platform for Electrochemical Devices. Advanced Functional Materials. https://doi.org/10.1002/adfm.201503902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.