Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Single‐Layer MoS2 Nanosheets with Amplified Photoacoustic Effect for Highly Sensitive Photoacoustic Imaging of Orthotopic Brain Tumors

Chen, Jingqin, Liu, Chengbo, Hu, Dehong, Wang, Feng, Wu, Haiwei, Gong, Xiaojing, Liu, Xin, Song, Liang, Sheng, Zonghai, Zheng, Hairong·2016·Advanced Functional Materials

Abstract

Photoacoustic (PA) imaging, as a fast growing technology that combines the high contrast of light and large penetration depth of ultrasound, has demonstrated great potential for molecular imaging of cancer. However, PA molecular imaging of orthotopic brain tumors is still challenging, partially due to the limited options and insufficient sensitivity of available PA molecular probes. Here, the direct formation of single‐layer (S‐MoS 2), few‐layer (F‐MoS 2), and multi‐layer (M‐MoS 2) nanosheets by the albumin‐assisted exfoliation without further surface modifications is reported. It is demonstrated that the PA effect of the MoS 2 nanosheets is highly dependent on their layered nanostructures. Decreasing the number of nanosheet layers from M‐MoS 2 to S‐MoS 2 can both significantly enhance the near‐infrared light absorption and improve the elastic properties of the nanomaterial, resulting in greatly amplified PA effect. The in vitro experiments demonstrate that the prepared S‐MoS 2 with excellent biocompatibility can be efficiently internalized into U87 glioma cells, producing strong PA signals for highly sensitive detection of brain tumor cells, with a detection limit of ≈100 cells. Intravenous administration of S‐MoS 2 to both U87 subcutaneous and orthotopic tumor‐bearing mice shows highly efficient tumor retention and significantly enhanced PA contrast. Tumor tissue ≈1.5 mm below the skull can still be clearly visualized in vivo. Previous studies suggest that the fabricated S‐MoS 2 with amplified PA effect have high potential to serve as an efficient nanoplatform for sensitive PA molecular imaging and hold promising prospect for translational medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201603758

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Chen, J., Liu, C., Hu, D., Wang, F., Wu, H., Gong, X., Liu, X., Song, L., Sheng, Z., & Zheng, H.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2016-09-26
Volume
26
Issue
47
Pages
8715-8725
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2527149985
Cited by
162
References
1
FWCI
10.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single‐Layer MoS2 Nanosheets with Amplified Photoacoustic Effect for Highly Sensitive Photoacoustic Imaging of Orthotopic Brain Tumors. https://app.cochat.ai/papers/10.1002/adfm.201603758
The paper
Chen, J., Liu, C., Hu, D., Wang, F., Wu, H., Gong, X., Liu, X., Song, L., Sheng, Z., & Zheng, H. (2016). Single‐Layer MoS2 Nanosheets with Amplified Photoacoustic Effect for Highly Sensitive Photoacoustic Imaging of Orthotopic Brain Tumors. Advanced Functional Materials. https://doi.org/10.1002/adfm.201603758

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.