The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrafine Graphene Nanomesh with Large On/Off Ratio for High‐Performance Flexible Biosensors
Abstract
Graphene is an attractive material for flexible electronics and biosensors, yet its zero bandgap nature has limited the on/off ratio of field‐effect transistors (FETs) and the sensitivity of biosensors based on graphene. Graphene nanomesh (GNM), a continuous 2D graphene nanostructure with a high density of holes punched in the basal plane, has been created to introduce lateral confinement and enable improved on/off ratio. However, the GNMs produced to date typically have a relatively large dimension (constriction neck width >5 nm) and low on/off ratio (≈100) limited by the resolution of the lithography process used. Here, the exploration of a directly grown mesoporous silica template is reported for the preparation of ultrafine GNMs with considerably narrower neck width (<3 nm) and strong quantum confinement to enable flexible FETs with greatly improved on/off ratio (up to 1000). With excellent electronic properties and high surface area for the functionalization of specific receptors, it is further shown that the GNM FETs can be readily used to construct highly sensitive biosensors for selective detection of human epidermal growth factor receptor 2, which is further demonstrated for real‐time detection of breast cancer cells overexpressed with receptor 2 down to single‐cell level. The studies provide a simple and scalable method to GNMs with potential applications for flexible nanoelectronics and biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Recent Advances in Aptamer Discovery and Applications
Zhang, Y., Lai, B. S., & Juhas, M. (2019) · Molecules · doi:10.3390/molecules24050941 · Cited by 663
Large-area graphene-nanomesh/carbon-nanotube hybrid membranes for ionic and molecular nanofiltration
Yang, Y., Yang, X., Liang, L., Gao, Y., Cheng, H., Li, X., Zou, M., Ma, R., Yuan, Q., & Duan, X. (2019) · Science · doi:10.1126/science.aau5321 · Cited by 648
Self-citationWang, Z., Wu, Z., Weng, L., Ge, S., Jiang, D., Huang, M., Mulvihill, D. M., Chen, Q., Guo, Z., Jazzar, A., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202301549 · Cited by 419
Wang, Z., Wang, X., Cong, S., Geng, F., & Zhao, Z. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100524 · Cited by 378
Metadata
- Authors
- Yang, Y., Yang, X., Zou, X., Wu, S., Wan, D., Cao, A., Liao, L., Yuan, Q., & Duan, X.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2016-12-02
- Volume
- 27
- Issue
- 19
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2559711428
- Cited by
- 164
- References
- 2
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrafine Graphene Nanomesh with Large On/Off Ratio for High‐Performance Flexible Biosensors. https://app.cochat.ai/papers/10.1002/adfm.201604096
- The paper
- Yang, Y., Yang, X., Zou, X., Wu, S., Wan, D., Cao, A., Liao, L., Yuan, Q., & Duan, X. (2017). Ultrafine Graphene Nanomesh with Large On/Off Ratio for High‐Performance Flexible Biosensors. Advanced Functional Materials. https://doi.org/10.1002/adfm.201604096
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.