Development and Translation of PEDOT:PSS Microelectrodes for Intraoperative Monitoring
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Recording neural activity during neurosurgical interventions is an invaluable tool for both improving patient outcomes and advancing our understanding of neural mechanisms and organization. However, increasing clinical electrodes' signal‐to‐noise and spatial specificity requires overcoming substantial physical barriers due to the compromised metal electrochemical interface properties. The electrochemical properties of poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) based interfaces surpass those of current clinical electrocorticography electrodes. Here, robust fabrication process of PEDOT:PSS microelectrode arrays is demonstrated for safe and high fidelity intraoperative monitoring of human brain. PEDOT:PSS microelectrodes measure significant differential neural modulation under various clinically relevant conditions. This study reports the first evoked (stimulus‐locked) cognitive activity with changes in amplitude across pial surface distances as small as 400 µm, potentially enabling basic neurophysiology studies at the scale of neural micro‐circuitry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Phonetic Feature Encoding in Human Superior Temporal Gyrus
Mesgarani, N., Cheung, C., Johnson, K., & Chang, E. F. (2014) · Science · doi:10.1126/science.1245994 · Cited by 993
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Cited by
Materials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Won, D., Kim, J., Choi, J., Kim, H., Han, S., Ha, I., Bang, J., Kim, K. K., Lee, Y., Kim, T.-S., et al. (2022) · Science Advances · doi:10.1126/sciadv.abo3209 · Cited by 288
Large-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
Self-citationConformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Electronics with shape actuation for minimally invasive spinal cord stimulation
Woodington, B. J., Curto, V. F., Yu, Y.-L., Martínez-Domínguez, H., Coles, L., Malliaras, G. G., Proctor, C. M., & Barone, D. G. (2021) · Science Advances · doi:10.1126/sciadv.abg7833 · Cited by 75
Self-citation
Metadata
- Authors
- Ganji, M., Kaestner, E., Hermiz, J., Rogers, N., Tanaka, A., Cleary, D., Lee, S. H., Snider, J., Halgren, M., Cosgrove, G. R., Carter, B. S., Barba, D., Uguz, I., Malliaras, G. G., Cash, S. S., Gilja, V., Halgren, E., & Dayeh, S. A.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-05-12
- Volume
- 28
- Issue
- 12
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2612742559
- Cited by
- 131
- References
- 14
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and Translation of PEDOT:PSS Microelectrodes for Intraoperative Monitoring. https://app.cochat.ai/papers/10.1002/adfm.201700232
- The paper
- Ganji, M., Kaestner, E., Hermiz, J., Rogers, N., Tanaka, A., Cleary, D., Lee, S. H., Snider, J., Halgren, M., Cosgrove, G. R., Carter, B. S., Barba, D., Uguz, I., Malliaras, G. G., Cash, S. S., Gilja, V., Halgren, E., & Dayeh, S. A. (2018). Development and Translation of PEDOT:PSS Microelectrodes for Intraoperative Monitoring. Advanced Functional Materials. https://doi.org/10.1002/adfm.201700232
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.