The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Radiopaque Highly Stiff and Tough Shape Memory Hydrogel Microcoils for Permanent Embolization of Arteries
Abstract
Transcatheter arterial embolization of aneurysm with metal microcoils is notoriously prone to recanalization arising from the low filling ratio due to their extreme rigidity. Smart hydrogel microcoils with tunable modulus may essentially significantly improve the therapeutic efficacy. Here, a radiopaque highly stiff body‐temperature‐triggered shape memory (SM) hydrogel is fabricated for the first time by introducing reversible hydrophobic dipole pairing microdomains in the flexibly crosslinked network, followed by BaSO 4 precipitation. This radiopacification does not affect their mechanical performances as well as the SM effect. It is demonstrated that the mechanical properties of SM hydrogels are comparable to those of rubbers and can be modulated by adjusting temperature ranging from 20 to 40 °C. Benefiting from the thermoresponsive mechanical properties, the stiff radiopaque hydrogel strip can easily pass through a catheter under the protection of cool saline for delivery into pig's renal artery, and spontaneously and rapidly transformed into a microcoil upon contacting blood. Real‐time angiogram reveals that continuous delivery of several hydrogel microcoils can efficiently occlude the blood supply. The kidneys are atrophied considerably over three month postoperative follow‐up, and no recanalization occurs throughout the experimental time. These novel hydrogel microcoils are promising to be developed as novel permanent embolic agents for treating aneurysm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Nonswellable” Hydrogel Without Mechanical Hysteresis
Kamata, H., Akagi, Y., Kayasuga-Kariya, Y., Chung, U.-I., & Sakai, T. (2014) · Science · doi:10.1126/science.1247811 · Cited by 669
Hampikian, J. M., Heaton, B. C., Tong, F. C., Zhang, Z., & Wong, C. P. (2006) · Materials Science and Engineering: C · doi:10.1016/j.msec.2005.08.026 · Cited by 101
Cited by
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Tailoring the Swelling‐Shrinkable Behavior of Hydrogels for Biomedical Applications
Feng, W., & Wang, Z. (2023) · Advanced Science · doi:10.1002/advs.202303326 · Cited by 548
Shape‐Memory Polymers for Biomedical Applications
Delaey, J., Dubruel, P., & Van Vlierberghe, S. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909047 · Cited by 407
Ionic liquid–based click-ionogels
Ren, Y., Guo, J., Liu, Z., Sun, Z., Wu, Y., Liu, L., & Yan, F. (2019) · Science Advances · doi:10.1126/sciadv.aax0648 · Cited by 392
Yao, Y., Xu, Z., Liu, B., Xiao, M., Yang, J., & Liu, W. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006944 · Cited by 335
Self-citation
Metadata
- Authors
- Zhang, Y., Gao, H., Wang, H., Xu, Z., Chen, X., Liu, B., Shi, Y., Lu, Y., Wen, L., Li, Y., Li, Z., Men, Y., Feng, X., & Liu, W.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-01-10
- Volume
- 28
- Issue
- 9
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2783498476
- Cited by
- 158
- References
- 2
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiopaque Highly Stiff and Tough Shape Memory Hydrogel Microcoils for Permanent Embolization of Arteries. https://app.cochat.ai/papers/10.1002/adfm.201705962
- The paper
- Zhang, Y., Gao, H., Wang, H., Xu, Z., Chen, X., Liu, B., Shi, Y., Lu, Y., Wen, L., Li, Y., Li, Z., Men, Y., Feng, X., & Liu, W. (2018). Radiopaque Highly Stiff and Tough Shape Memory Hydrogel Microcoils for Permanent Embolization of Arteries. Advanced Functional Materials. https://doi.org/10.1002/adfm.201705962
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.