The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Auxetic Cardiac Patches with Tunable Mechanical and Conductive Properties toward Treating Myocardial Infarction
Open accessAbstract
An auxetic conductive cardiac patch (AuxCP) for the treatment of myocardial infarction (MI) is introduced. The auxetic design gives the patch a negative Poisson's ratio, providing it with the ability to conform to the demanding mechanics of the heart. The conductivity allows the patch to interface with electroresponsive tissues such as the heart. Excimer laser microablation is used to micropattern a re‐entrant honeycomb (bow‐tie) design into a chitosan‐polyaniline composite. It is shown that the bow‐tie design can produce patches with a wide range in mechanical strength and anisotropy, which can be tuned to match native heart tissue. Further, the auxetic patches are conductive and cytocompatible with murine neonatal cardiomyocytes in vitro. Ex vivo studies demonstrate that the auxetic patches have no detrimental effect on the electrophysiology of both healthy and MI rat hearts and conform better to native heart movements than unpatterned patches of the same material. Finally, the AuxCP applied in a rat MI model results in no detrimental effect on cardiac function and negligible fibrotic response after two weeks in vivo. This approach represents a versatile and robust platform for cardiac biomaterial design and could therefore lead to a promising treatment for MI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Global atlas on cardiovascular disease prevention and control.
Mendis, S., Puska, P., & Norrving, B. G. (2011) · Virtual Defense Library (Ministerio de Defensa) · Cited by 2,691
Theory and Practice of Histological Techniques
Goss, G. (2009) · American Journal of Surgical Pathology · doi:10.1097/pas.0b013e3181805089 · Cited by 1,773
Complexity in biomaterials for tissue engineering
Place, E. S., Evans, N. D., & Stevens, M. M. (2009) · Nature Materials · doi:10.1038/nmat2441 · Cited by 1,728
Self-citationConducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Auxetic Materials: Functional Materials and Structures from Lateral Thinking!
Evans, K. E., & Alderson, A. (2000) · Advanced Materials · doi:10.1002/(sici)1521-4095(200005)12:9<617::aid-adma617>3.0.co;2-3 · Cited by 1,381
Models for the elastic deformation of honeycombs
Masters, I. G., & Evans, K. E. (1996) · Composite Structures · doi:10.1016/s0263-8223(96)00054-2 · Cited by 1,095
Laflamme, M. A., & Murry, C. E. (2005) · Nature Biotechnology · doi:10.1038/nbt1117 · Cited by 964
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
Topology Optimized Architectures with Programmable Poisson's Ratio over Large Deformations
Clausen, A., Wang, F., Jensen, J. S., Sigmund, O., & Lewis, J. A. (2015) · Advanced Materials · doi:10.1002/adma.201502485 · Cited by 551
Cited by
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Flexible Metamaterial Electronics
Jiang, S., Liu, X., Liu, J., Ye, D., Duan, Y., Li, K., Yin, Z., & Huang, Y. (2022) · Advanced Materials · doi:10.1002/adma.202200070 · Cited by 332
High‐Aspect‐Ratio Nanostructured Surfaces as Biological Metamaterials
Higgins, S. G., Becce, M., Belessiotis‐Richards, A., Seong, H., Sero, J. E., & Stevens, M. M. (2020) · Advanced Materials · doi:10.1002/adma.201903862 · Cited by 256
Self-citationInjectable and conductive cardiac patches repair infarcted myocardium in rats and minipigs
Wang, L., Liu, Y., Ye, G., He, Y., Li, B., Guan, Y., Gong, B., Mequanint, K., Xing, M. M. Q., & Qiu, X. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00796-9 · Cited by 207
Metadata
- Authors
- Kapnisi, M., Mansfield, C., Marijon, C., Guex, A. G., Perbellini, F., Bardi, I., Humphrey, E. J., Puetzer, J. L., Mawad, D., Koutsogeorgis, D. C., Stuckey, D. J., Terracciano, C. M., Harding, S. E., & Stevens, M. M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-04-10
- Volume
- 28
- Issue
- 21
- Pages
- 1800618-1800618
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2797769126
- Cited by
- 278
- References
- 36
- FWCI
- 19.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Auxetic Cardiac Patches with Tunable Mechanical and Conductive Properties toward Treating Myocardial Infarction. https://app.cochat.ai/papers/10.1002/adfm.201800618
- The paper
- Kapnisi, M., Mansfield, C., Marijon, C., Guex, A. G., Perbellini, F., Bardi, I., Humphrey, E. J., Puetzer, J. L., Mawad, D., Koutsogeorgis, D. C., Stuckey, D. J., Terracciano, C. M., Harding, S. E., & Stevens, M. M. (2018). Auxetic Cardiac Patches with Tunable Mechanical and Conductive Properties toward Treating Myocardial Infarction. Advanced Functional Materials. https://doi.org/10.1002/adfm.201800618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.