The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Transcatheter Self‐Powered Ultrasensitive Endocardial Pressure Sensor
Abstract
Changes in endocardial pressure (EP) have important clinical significance for heart failure patients with impaired cardiac function. As a vital parameter for evaluating cardiac function, EP is commonly monitored by invasive and expensive cardiac catheterization, which is not feasible for long‐term and continuous data collection. In this work, a miniaturized, flexible, and self‐powered endocardial pressure sensor (SEPS) based on triboelectric nanogenerator (TENG), which is integrated with a surgical catheter for minimally invasive implantation, is reported. In a porcine model, SEPS is implanted into the left ventricle and the left atrium. The SEPS has a good response both in low‐ and high‐pressure environments. The SEPS achieves the ultrasensitivity, real‐time monitoring, and mechanical stability in vivo. An excellent linearity ( R 2 = 0.997) with a sensitivity of 1.195 mV mmHg −1 is obtained. Furthermore, cardiac arrhythmias such as ventricular fibrillation and ventricular premature contraction can also be detected by SEPS. The device may promote the development of miniature implantable medical sensors for monitoring and diagnosis of cardiovascular diseases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Figure 3b, (Liu et al. 2019) presents a novel approach to monitoring intracardiac pressure using a self-powered pressure sensor (SEPS) that is integrated with a minimally invasive implanted heart catheter.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Liu et al. 2019
In the citing paper
“The SEPS demonstrated its feasibility through in vitro and in vivo experiments, addressing the limitations of traditional invasive monitoring methods by providing a minimally invasive and self-powered solution.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Liu et al. 2019
In the citing paper
“After optimization exploration, SEPS achieved a sensitivity of 1.195 mV/mmHg with a linearity of R2=0.997.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Liu et al. 2019
Citations
Cites
The SOLVD Investigators* (1991) · New England Journal of Medicine · doi:10.1056/nejm199108013250501 · Cited by 8,029
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Self-citationFlexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Self-citationOn Maxwell's displacement current for energy and sensors: the origin of nanogenerators
Wang, Z. L. (2017) · Materials Today · doi:10.1016/j.mattod.2016.12.001 · Cited by 2,095
Self-citationIn vivo recordings of brain activity using organic transistors
Khodagholy, D., Doublet, T., Quilichini, P., Gurfinkel, M., Leleux, P., Ghestem, A., Ismailova, E., Hervé, T., Sanaur, S., Bernard, C., et al. (2013) · Nature Communications · doi:10.1038/ncomms2573 · Cited by 1,057
Structural control of mixed ionic and electronic transport in conducting polymers
Rivnay, J., Inal, S., Collins, B. A., Sessolo, M., Stavrinidou, E., Strakosas, X., Tassone, C. J., DeLongchamp, D. M., & Malliaras, G. G. (2016) · Nature Communications · doi:10.1038/ncomms11287 · Cited by 950
High-performance transistors for bioelectronics through tuning of channel thickness
Rivnay, J., Leleux, P., Ferro, M. D., Sessolo, M., Williamson, A., Koutsouras, D. A., Khodagholy, D., Ramuz, M. P., Strakosas, X., Owens, R. M., et al. (2015) · Science Advances · doi:10.1126/sciadv.1400251 · Cited by 738
Self‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 702
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Self-citationIn Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Self-citation
Flagged first, then by citations
1 of the 35 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Angie R., 2014, Eur. J. Heart Failure, 4, 283
- B.Brochway G.Doten(CROMPTON SEAGER & TUFTE LLC) US 2002/0120200 A1 2002. · DOI
- Stein P. D., 1980, Am. J. Physiol., 238, H625
Cited by
Sorted by citations
Items 301–308 of 308
Chen, Z., Lu, H., Wu, H., He, G., Chen, Z., Wang, B., Yu, S., & Li, H. (2026) · Nano Research · doi:10.26599/nr.2026.94908415
Self-citationAddition shaped microstrip patch antenna design for optimizing the results
Gour, S., Singh, G., Mathur, G., & Solanki, B. S. (2025) · IEEE International Conference on Intelligent Signal Processing and Effective Communication Technologies (INSPECT) · doi:10.1109/inspect67393.2025.11350309
Nonvolatile electrically controlled spin valve via homojunction engineering
Zhang, Y., Sa, B., Zhou, J., & Sun, Z. (2026) · Physical review. B./Physical review. B · doi:10.1103/4dv3-h2yn
Zhang, T., Cai, Y., Xu, X., Yao, C., Gao, L., Li, M., Cai, Y., Liu, S. K., Gao, S., Wang, C., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04012
Thermally Conductive and Compliant PIB−hBN Nanocomposite Encapsulation for Soft Neural Interfaces
Raza, U., Gomez-Stafford, J., & Kim, K. (2026) · ACS Applied Bio Materials · doi:10.1021/acsabm.6c00210
Baburaj, A., Aliyana, A. K., Kumar, S. K. N., & Stylios, G. K. (2026) · Royal Society of Chemistry eBooks · doi:10.1039/9781837679850-00098
Self-sustaining leadless intracardiac pacemaker powered by triboelectric nanogenerator
Chen, P., Wang, R., Schmuck, E. G., Wang, D., Modaff, D. S., Zhou, T., Osaki, S., Liu, W., Pan, F., Kim, J., et al. (2026) · Science Advances · doi:10.1126/sciadv.aef8903
Chu, D., Hou, Q., Li, M., & Dong, Y. (2026) · Gels · doi:10.3390/gels12100919
Metadata
- Authors
- Liu, Z., Ma, Y., Ouyang, H., Shi, B., Li, N., Jiang, D., Xie, F., Qu, D., Zou, Y., Huang, Y., Li, H., Zhao, C., Tan, P., Yu, M., Fan, Y., Zhang, H., Wang, Z. L., & Li, Z.
- Affiliations
- Beihang University (CN)
- Second Military Medical University (CN)
- Chinese Academy of Sciences (CN)
- National Research Center for Rehabilitation Technical Aids (CN)
- Georgia Institute of Technology (US)
- Corresponding author
- Fan, Yubo
- Zhang, Hao
- Wang, Zhong Lin
- Li, Zhou
- ORCID
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-11-23
- Volume
- 29
- Issue
- 3
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2901061669
- Cited by
- 308
- References
- 35
- Citations by year
- 2026: 13 · 2025: 31 · 2024: 46 · 2023: 48 · 2022: 50 · 2021: 48 · 2020: 47 · 2019: 24 · 2018: 1
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Functional Materials (publishedVersion)
- Funders
- National Natural Science Foundation of China (61875015, 31571006, 11421202, 81601629, 61501039, 81800443, 21801019)
- Natural Science Foundation of Beijing Municipality (2182091, 2162017)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- triboelectric nanogenerator, self-powered sensors, biomedical implants, cardiac function monitoring, heart failure, flexible sensors, arrhythmia detection, ventricular fibrillation, premature ventricular contractions, porcine model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review