The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Textile‐Based Wireless Pressure Sensor Array for Human‐Interactive Sensing
Abstract
A textile‐based wireless pressure sensor array (WiPSA) is proposed for flexible remote tactile sensing applications. The WiPSA device is composed of a fabric spacer sandwiched by two separate layers of passive antennas and ferrite film units. Under the external pressure, the mechanical compression of the flexible fabric spacer leads to an inductance change, which can further be transduced to a detectable shift of the resonant frequency. Importantly, WiPSA integrates the ferrite film featuring an ultrahigh permeability, which effectively improves the device sensitivity and avoids the interference of conductive materials simultaneously. The device performance with a high quality factor (>35) and sensitivity (−0.19 MHz kPa−1) within a pressure range of 0–20 kPa is demonstrated. In addition, WiPSA achieves excellent reproducibility under periodical pressures (>20 000 cycles), temperature fluctuations (15–103 °C), and humidity variations (40–99%). As a proof of concept for human‐interactive sensing, WiPSA is successfully 1) integrated with a flexible wrist band for fingertip pressure‐guided direction choices, 2) developed into a smart wireless insole to map the plantar stress distributions, and 3) embedded into a waist‐supporting belt to resolve the contact pressure between the belt and human abdomen in a remote transmitting scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection
Zang, Y., Zhang, F., Huang, D., Gao, X., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms7269 · Cited by 548
Cited by
Wen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Metadata
- Authors
- Nie, B., Huang, R., Yao, T., Zhang, Y., Miao, Y., Liu, C., Liu, J., & Chen, X.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-02-21
- Volume
- 29
- Issue
- 22
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2917989266
- Cited by
- 217
- References
- 4
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Textile‐Based Wireless Pressure Sensor Array for Human‐Interactive Sensing. https://app.cochat.ai/papers/10.1002/adfm.201808786
- The paper
- Nie, B., Huang, R., Yao, T., Zhang, Y., Miao, Y., Liu, C., Liu, J., & Chen, X. (2019). Textile‐Based Wireless Pressure Sensor Array for Human‐Interactive Sensing. Advanced Functional Materials. https://doi.org/10.1002/adfm.201808786
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.