The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Organic Photodetectors and their Application in Large Area and Flexible Image Sensors: The Role of Dark Current
Open accessAbstract
Organic photodetectors (OPDs) have gained increasing interest as they offer cost‐effective fabrication methods using low temperature processes, making them particularly attractive for large area image detectors on lightweight flexible plastic substrates. Moreover, their photophysical and optoelectronic properties can be tuned both at a material and device level. Visible‐light OPDs are proposed for use in indirect‐conversion X‐ray detectors, fingerprint scanners, and intelligent surfaces for gesture recognition. Near‐infrared OPDs find applications in biomedical imaging and optical communications. For most applications, minimizing the OPD dark current density (Jd) is crucial to improve important figures of merits such as the signal‐to‐noise ratio, the linear dynamic range, and the specific detectivity (D*). Here, a quantitative analysis of the intrinsic dark current processes shows that charge injection from the electrodes is the dominant contribution to Jd in OPDs. Jd reduction is typically addressed by fine‐tuning the active layer energetics and stratification or by using charge blocking layers. Yet, most experimental Jd values are higher than the calculated intrinsic limit. Possible reasons for this deviation are discussed, including extrinsic defects in the photoactive layer and the presence of trap states. This provides the reader with guidelines to improve the OPD performances in view of imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design Rules for Donors in Bulk‐Heterojunction Solar Cells—Towards 10 % Energy‐Conversion Efficiency
Scharber, M. C., Mühlbacher, D., Koppe, M., Denk, P., Waldauf, C., Heeger, A. J., & Brabec, C. J. (2006) · Advanced Materials · doi:10.1002/adma.200501717 · Cited by 5,205
Liang, Y., Xu, Z., Xia, J., Tsai, S., Wu, Y., Li, G., Ray, C., & Yu, L. (2010) · Advanced Materials · doi:10.1002/adma.200903528 · Cited by 3,649
Organic Light Detectors: Photodiodes and Phototransistors
Baeg, K., Binda, M., Natali, D., Caironi, M., & Noh, Y. (2013) · Advanced Materials · doi:10.1002/adma.201204979 · Cited by 1,344
Bulk Heterojunction Solar Cells: Morphology and Performance Relationships
Huang, Y., Kramer, E. J., Heeger, A. J., & Bazan, G. C. (2014) · Chemical Reviews · doi:10.1021/cr400353v · Cited by 1,249
Efficiency of bulk-heterojunction organic solar cells
Scharber, M. C., & Sariciftci, N. S. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.05.001 · Cited by 1,088
Approaching disorder-free transport in high-mobility conjugated polymers
Venkateshvaran, D., Nikolka, M., Sadhanala, A., Lemaur, V., Zelazny, M., Kepa, M., Hurhangee, M., Kronemeijer, A. J., Pecunia, V., Nasrallah, I., et al. (2014) · Nature · doi:10.1038/nature13854 · Cited by 1,050
Unified Description of Charge-Carrier Mobilities in Disordered Semiconducting Polymers
Pasveer, W. F., Cottaar, J., Tanase, C., Coehoorn, R., Bobbert, P. A., Blom, P. W. M., de Leeuw, D. M., & Michels, M. A. J. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.206601 · Cited by 971
Organic Photodiodes: The Future of Full Color Detection and Image Sensing
Jansen‐van Vuuren, R. D., Armin, A., Pandey, A. K., Burn, P. L., & Meredith, P. (2016) · Advanced Materials · doi:10.1002/adma.201505405 · Cited by 819
All-organic optoelectronic sensor for pulse oximetry
Lochner, C. M., Khan, Y., Pierre, A., & Arias, A. C. (2014) · Nature Communications · doi:10.1038/ncomms6745 · Cited by 726
Narrowband light detection via internal quantum efficiency manipulation of organic photodiodes
Armin, A., Jansen-van Vuuren, R. D., Kopidakis, N., Burn, P. L., & Meredith, P. (2015) · Nature Communications · doi:10.1038/ncomms7343 · Cited by 592
Electronic Processes in Organic Semiconductors: An Introduction
Köhler, A., & Bässler, H. (2015) · Wiley eBooks · doi:10.1002/9783527685172 · Cited by 493
Unification of trap-limited electron transport in semiconducting polymers
Nicolai, H. T., Kuik, M., Wetzelaer, G. A. H., de Boer, B., Campbell, C., Risko, C., Brédas, J. L., & Blom, P. W. M. (2012) · Nature Materials · doi:10.1038/nmat3384 · Cited by 470
Nikolka, M., Nasrallah, I., Rose, B., Ravva, M. K., Broch, K., Sadhanala, A., Harkin, D., Charmet, J., Hurhangee, M., Brown, A., et al. (2017) · Nature Materials · doi:10.1038/nmat4785 · Cited by 440
Wave-packet approach to noise in multichannel mesoscopic systems
Martin, T., & Landauer, R. (1992) · Physical Review B · doi:10.1103/physrevb.45.1742 · Cited by 416
Organic narrowband near-infrared photodetectors based on intermolecular charge-transfer absorption
Siegmund, B., Mischok, A., Benduhn, J., Zeika, O., Ullbrich, S., Nehm, F., Böhm, M., Spoltore, D., Fröb, H., Körner, C., et al. (2017) · Nature Communications · doi:10.1038/ncomms15421 · Cited by 323
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
Kielar, M., Dhez, O., Pecastaings, G., Curutchet, A., & Hirsch, L. (2016) · Scientific Reports · doi:10.1038/srep39201 · Cited by 251
Cowan, S. R., Leong, W. L., Banerji, N., Dennler, G., & Heeger, A. J. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201100514 · Cited by 229
High Detectivity All‐Printed Organic Photodiodes
Pierre, A., Deckman, I., Lechêne, P. B., & Arias, A. C. (2015) · Advanced Materials · doi:10.1002/adma.201502238 · Cited by 212
Polymer:Fullerene Bimolecular Crystals for Near‐Infrared Spectroscopic Photodetectors
Tang, Z., Ma, Z., Sánchez‐Díaz, A., Ullbrich, S., Liu, Y., Siegmund, B., Mischok, A., Leo, K., Campoy‐Quiles, M., Li, W., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702184 · Cited by 207
General rule for the energy of water-induced traps in organic semiconductors
Zuo, G., Linares, M., Upreti, T., & Kemerink, M. (2019) · Nature Materials · doi:10.1038/s41563-019-0347-y · Cited by 162
Zhou, X., Yang, D., & Ma, D. (2015) · Advanced Optical Materials · doi:10.1002/adom.201500224 · Cited by 157
Saracco, E., Bouthinon, B., Verilhac, J., Celle, C., Chevalier, N., Mariolle, D., Dhez, O., & Simonato, J. (2013) · Advanced Materials · doi:10.1002/adma.201302338 · Cited by 150
Guo, F., Xiao, Z., & Huang, J. (2013) · Advanced Optical Materials · doi:10.1002/adom.201200071 · Cited by 144
Clarke, T. M., Lungenschmied, C., Peet, J., Drolet, N., & Mozer, A. J. (2014) · Advanced Energy Materials · doi:10.1002/aenm.201401345 · Cited by 142
High sensitivity organic photodiodes with low dark currents and increased lifetimes
Ramuz, M. P., Bürgi, L., Winnewisser, C., & Seitz, P. (2008) · Organic Electronics · doi:10.1016/j.orgel.2008.01.007 · Cited by 137
Agostinelli, T., Campoy‐Quiles, M., Blakesley, J. C., Speller, R. D., Bradley, D. D. C., & Nelson, J. (2008) · Applied Physics Letters · doi:10.1063/1.3028640 · Cited by 126
Visible and Near‐Infrared Imaging with Nonfullerene‐Based Photodetectors
Gasparini, N., Gregori, A., Salvador, M. F., Biele, M., Wadsworth, A., Tedde, S. F., Baran, D., McCulloch, I. A., & Brabec, C. J. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800104 · Cited by 123
High detectivity squaraine-based near infrared photodetector with nA/cm2 dark current
Binda, M., Iacchetti, A., Natali, D., Beverina, L., Sassi, M., & Sampietro, M. (2011) · Applied Physics Letters · doi:10.1063/1.3553767 · Cited by 108
Spray‐Coated Organic Photodetectors and Image Sensors with Silicon‐Like Performance
Biele, M., Benavides, C. M., Huerdler, J. E., Tedde, S. F., Brabec, C. J., & Schmidt, O. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800158 · Cited by 103
Interface Trap States in Organic Photodiodes
Arca, F., Tedde, S. F., Sramek, M., Rauh, J., Lugli, P., & Hayden, O. (2013) · Scientific Reports · doi:10.1038/srep01324 · Cited by 80
Morimune, T., Kajii, H., & Ohmori, Y. (2006) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2006.887786 · Cited by 73
High‐Performance, Fullerene‐Free Organic Photodiodes Based on a Solution‐Processable Indigo
Kim, I. K., Li, X., Ullah, M., Shaw, P. E., Wawrzinek, R., Namdas, E. B., & Lo, S. (2015) · Advanced Materials · doi:10.1002/adma.201502936 · Cited by 71
Temperature-Dependent Detectivity of Near-Infrared Organic Bulk Heterojunction Photodiodes
Wu, Z., Yao, W., London, A. E., Azoulay, J. D., & Ng, T. N. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b12162 · Cited by 71
Benavides, C. M., Murto, P., Chochos, C. L., Gregoriou, V. G., Avgeropoulos, A., Xu, X., Bini, K., Sharma, A., Andersson, M. R., Schmidt, O., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03824 · Cited by 65
Fast Organic Near-Infrared Photodetectors Based on Charge-Transfer Absorption
Ullbrich, S., Siegmund, B., Mischok, A., Hofacker, A., Benduhn, J., Spoltore, D., & Vandewal, K. (2017) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.7b02571 · Cited by 54
Visible-Light-Responsive High-Detectivity Organic Photodetectors with a 1 μm Thick Active Layer
Park, J. B., Ha, J., Yoon, S. C., Lee, C., Jung, I. H., & Hwang, D. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b13550 · Cited by 52
Eom, S. H., Nam, S. Y., Do, H. J., Lee, J., Jeon, S., Shin, T. J., Jung, I. H., Yoon, S. C., & Lee, C. (2017) · Polymer Chemistry · doi:10.1039/c7py00497d · Cited by 38
A Monolithically Processed Rectifying Pixel for High‐Resolution Organic Imagers
Zalar, P., Matsuhisa, N., Suzuki, T., Enomoto, S., Koizumi, M., Yokota, T., Sekino, M., & Someya, T. (2018) · Advanced Electronic Materials · doi:10.1002/aelm.201700601 · Cited by 31
Wu, Y., Matsuhisa, N., Zalar, P., Fukuda, K., Yokota, T., & Someya, T. (2018) · Advanced Electronic Materials · doi:10.1002/aelm.201800311 · Cited by 20
Cited by
Li, C., Wang, H., Wang, F., Li, T., Xu, M., Wang, H., Wang, Z., Zhan, X., Hu, W., & Shen, L. (2020) · Light: Science & Applications · doi:10.1038/s41377-020-0264-5 · Cited by 581
The Bulk Heterojunction in Organic Photovoltaic, Photodetector, and Photocatalytic Applications
Wadsworth, A., Hamid, Z., Kosco, J., Gasparini, N., & McCulloch, I. (2020) · Advanced Materials · doi:10.1002/adma.202001763 · Cited by 332
Reverse dark current in organic photodetectors and the major role of traps as source of noise
Kublitski, J., Hofacker, A., Boroujeni, B. K., Benduhn, J., Nikolis, V. C., Kaiser, C., Spoltore, D., Kleemann, H., Fischer, A., Ellinger, F., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20856-z · Cited by 309
Recent Progress on Broadband Organic Photodetectors and their Applications
Zhao, Z., Xu, C., Niu, L., Zhang, X., & Zhang, F. (2020) · Laser & Photonics Reviews · doi:10.1002/lpor.202000262 · Cited by 290
Nodari, D., Hart, L. J. F., Sandberg, O. J., Furlan, F., Angela, E., Panidi, J., Qiao, Z., McLachlan, M. A., Barnes, P. R. F., Durrant, J. R., et al. (2024) · Advanced Materials · doi:10.1002/adma.202401206 · Cited by 48
Metadata
- Authors
- Simone, G., Dyson, M. J., Meskers, S. C. J., Janssen, R. A. J., & Gelinck, G. H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-11-07
- Volume
- 30
- Issue
- 20
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2983019972
- Cited by
- 473
- References
- 40
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.