The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Highly Efficient and Water‐Insensitive Self‐Healing Elastomer for Wet and Underwater Electronics
Open accessAbstract
Integrating self‐healing capabilities into soft electronic devices increases their durability and long‐term reliability. Although some advances have been made, the use of self‐healing electronics in wet and/or (under)water environments has proven to be quite challenging, and has not yet been fully realized. Herein, a new highly water insensitive self‐healing elastomer with high stretchability and mechanical strength that can reach 1100% and ≈6.5 MPa, respectively, is reported. The elastomer exhibits a high (>80%) self‐healing efficiency (after ≈ 24 h) in high humidity and/or different (under)water conditions without the assistance of an external physical and/or chemical triggers. Soft electronic devices made from this elastomer are shown to be highly robust and able to recover their electrical properties after damages in both ambient and aqueous conditions. Moreover, once operated in extreme wet or underwater conditions (e.g., salty sea water), the self‐healing capability leads to the elimination of significant electrical leakage that would be caused by structural damages. This highly efficient self‐healing elastomer can help extend the use of soft electronics outside of the laboratory and allow a wide variety of wet and submarine applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
One‐Dimensional Nanomaterials for Soft Electronics
Gong, S., & Cheng, W. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600314 · Cited by 361
Cited by
Li, Z., Zhu, Y., Niu, W., Yang, X., Jiang, Z., Lu, Z., Liu, X., & Sun, J. (2021) · Advanced Materials · doi:10.1002/adma.202101498 · Cited by 668
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationLi, Y., Yang, D., Wu, Z., Gao, F.-L., Gao, X.-Z., Zhao, H.-Y., Li, X., & Yu, Z.-Z. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108324 · Cited by 313
Metadata
- Authors
- Khatib, M., Zohar, O., Saliba, W., Srebnik, S., & Haick, H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-04-06
- Volume
- 30
- Issue
- 22
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3014355484
- Cited by
- 163
- References
- 3
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Efficient and Water‐Insensitive Self‐Healing Elastomer for Wet and Underwater Electronics. https://app.cochat.ai/papers/10.1002/adfm.201910196
- The paper
- Khatib, M., Zohar, O., Saliba, W., Srebnik, S., & Haick, H. (2020). Highly Efficient and Water‐Insensitive Self‐Healing Elastomer for Wet and Underwater Electronics. Advanced Functional Materials. https://doi.org/10.1002/adfm.201910196
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.