The DOI matches its Crossref record; 208 of the 211 references it cites were found in a registry or an index.
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Abstract
Skin is the largest organ of the human body, and it offers a diagnostic interface rich with vital biological signals from the inner organs, blood vessels, muscles, and dermis/epidermis. Soft, flexible, and stretchable electronic devices provide a novel platform to interface with soft tissues for robotic feedback and control, regenerative medicine, and continuous health monitoring. Here, we introduce the term "lab-on-skin" to describe a set of electronic devices that have physical properties, such as thickness, thermal mass, elastic modulus, and water-vapor permeability, which resemble those of the skin. These devices can conformally laminate on the epidermis to mitigate motion artifacts and mismatches in mechanical properties created by conventional, rigid electronics while simultaneously providing accurate, non-invasive, long-term, and continuous health monitoring. Recent progress in the design and fabrication of soft sensors with more advanced capabilities and enhanced reliability suggest an impending translation of these devices from the research lab to clinical environments. Regarding these advances, the first part of this manuscript reviews materials, design strategies, and powering systems used in soft electronics. Next, the paper provides an overview of applications of these devices in cardiology, dermatology, electrophysiology, and sweat diagnostics, with an emphasis on how these systems may replace conventional clinical tools. The review concludes with an outlook on current challenges and opportunities for future research directions in wearable health monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Of the two, non-invasive sensors are more extensively researched and is generally preferred by many patients.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [291]
Citations
Cites
Issues and challenges facing rechargeable lithium batteries
Tarascon, J.-M., & Armand, M. (2001) · Nature · doi:10.1038/35104644 · Cited by 21,130 · cited 1×
“cracked after repeated bending to a 10 mm radius of curvature.(139) Printable conductive inks(138)”
BackgroundCarbon-Based Supercapacitors Produced by Activation of Graphene
Zhu, Y., Murali, S., Stoller, M. D., Ganesh, K. J., Cai, W., Ferreira, P. J., Pirkle, A., Wallace, R. M., Cychosz, K. A., Thommes, M., et al. (2011) · Science · doi:10.1126/science.1200770 · Cited by 6,140 · cited 1×
“high theoretical specific surface area (2630 m(2)g).(148) However, for the majority of graphenePage 29 of 65”
BackgroundWireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 3×
“information useful to monitor activity in athletes during sporting events (Figure 9b).(42) The”
BackgroundInfluentialKim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836 · cited 5×
“thereby enabling optimal conformal skin-device contact, adhesion, and transpiration.(5) The”
BackgroundMethodInfluentialLaser Scribing of High-Performance and Flexible Graphene-Based Electrochemical Capacitors
El-Kady, M. F., Strong, V., Dubin, S., & Kaner, R. B. (2012) · Science · doi:10.1126/science.1216744 · Cited by 4,008
Tensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941
Lemaitre, J., Chaboche, J. L., & Maji, A. K. (1993) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1993)119:3(642.2 · Cited by 3,317
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247 · cited 1×
“dimensional nanomaterials.(93,197) Although metallic sensing elements usually provide better”
Background
Research works printed but not linked: 8
- Jog N. K., 2013, Electronics in Medicine and Biomedical Instrumentation
- Ravariu C., 2001, Semiconductor Conference, 2001. CAS 2001, 379
- Rieger M. M., 1974, J. Soc. Cosmet. Chem., 25, 253
- Friberg S. E., 1990, J. Soc. Cosmet. Chem., 41, 155
- 10.1046/j.1467-2494.2000.00037.x · doi:10.1046/j.1467-2494.2000.00037.x · Paper page
- Robinson, A. J.; Snyder-Mackler, L.Clinical Electrophysiology: Electrotherapy and Electrophysiologic Testing;Lippincott Williams & Wilkins:Philadelphia, PA, 2008.
- 10.1073/pnas.1605720113 · DOI · Paper page
- 10.1063/1.4905015 · DOI
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Dong, K., Peng, X., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.201902549 · Cited by 1,322
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Metadata
- Authors
- Liu, Y., Pharr, M., & Salvatore, G. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Texas A&M University (US)
- ETH Zurich (CH)
- Corresponding author
- Liu, Yuhao
- Pharr, Matt
- Salvatore, Giovanni Antonio
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-09-25
- Volume
- 11
- Issue
- 10
- Pages
- 9614-9635
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2755528635
- Cited by
- 1,725
- References
- 211
- Citations by year
- 2026: 139 · 2025: 150 · 2024: 202 · 2023: 178 · 2022: 226 · 2021: 267 · 2020: 258 · 2019: 197 · 2018: 103 · 2017: 3
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- ARCA (Università Ca' Foscari Venezia) (submittedVersion)
- Funders
- Texas A and M Engineering Experiment Station, Texas A and M University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- flexible electronics, stretchable electronics, wearable health monitoring, soft sensors, non-invasive monitoring, cardiac monitoring, dermatology, electrophysiology
- MeSH terms
- Wearable Electronic Devices, Electronics, Equipment Design, Humans, Monitoring, Physiologic, Skin
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring. https://app.cochat.ai/papers/10.1021/acsnano.7b04898
- The paper
- Liu, Y., Pharr, M., & Salvatore, G. A. (2017). Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring. ACS Nano. https://doi.org/10.1021/acsnano.7b04898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.