The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Electrically Conductive Hydrogel Nerve Guidance Conduits for Peripheral Nerve Regeneration
Abstract
Peripheral nerve injuries are serious conditions, and surgical treatment has critical limitations. Therefore, nerve guidance conduits (NGCs) are proposed as an alternative. In this study, multifunctional NGCs are fabricated for the regeneration of injured peripheral nerves. Graphene oxide (GO) and gelatin‐methacrylate (GelMA) are polymerized and chemically reduced to form reduced (GO/GelMA) (r(GO/GelMA)). The prepared materials present good electrical conductivity, flexibility, mechanical stability, and permeability, which are suitable for use as NGCs. In vitro studies show 2.1‐ and 1.4‐fold promotion of neuritogenesis of PC12 neuronal cells on r(GO/GelMA) compared to GelMA and unreduced GO/GelMA, respectively. Animal studies using a rat sciatic nerve injury model with a 10 mm gap between the proximal and distal regions of the defect reveal that r(GO/GelMA) NGCs significantly enhance peripheral nerve regeneration, indicated by improved muscle weight increase, electro‐conduction velocity, and sciatic nerve function index. Specifically, r(GO/GelMA) NGCs are utilized to potentiate regrowth with myelination in rat sciatic nerves followed by histological, immunohistological, and morphometrical analyses. This study successfully shows the feasibility of electrically conductive hydrogel NGCs as functional conduits for improved nerve regeneration in a preclinical study, where these NGCs can not only mimic nerve tissues but also strongly promote nerve regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The chemistry of graphene oxide
Dreyer, D. R., Park, S., Bielawski, C. W., & Ruoff, R. S. (2010) · Chem. Soc. Rev. · doi:10.1039/b917103g · Cited by 11,653
Self-citationIdentification of ubiquitin ligases required for skeletal muscle atrophy.
Bodine, S. C., Latres, E., Baumhueter, S., Lai, V. K.-M., Nunez, L., Clarke, B. A., Poueymirou, W. T., Panaro, F. J., Na, E., Dharmarajan, K., et al. (2001) · Science · doi:10.1126/science.1065874 · Cited by 3,521
Mechanisms of axon ensheathment and myelin growth
Sherman, D. L., & Brophy, P. J. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1743 · Cited by 668
Cited by
Multifunctional GelMA platforms with nanomaterials for advanced tissue therapeutics
Kurian, A. G., Singh, R. K., Patel, K. D., Lee, J.-H., & Kim, H.-W. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.06.027 · Cited by 444
Self-citationFan, L., Liu, C., Chen, X., Zheng, L., Zou, Y., Wen, H., Guan, P., Lu, F., Luo, Y., Tan, G., et al. (2022) · Advanced Science · doi:10.1002/advs.202105586 · Cited by 401
Ansari, M. J., Rajendran, R. R., Mohanto, S., Agarwal, U., Panda, K., Dhotre, K., Manne, R., Deepak, A., Zafar, A., Yasir, M., et al. (2022) · Gels · doi:10.3390/gels8070454 · Cited by 337
Ma, Y., Wang, H., Wang, Q., Cao, X., & Gao, H. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.139424 · Cited by 103
Zhou, W., Rahman, M. S. U., Sun, C., Li, S., Zhang, N., Chen, H., Han, C. C., Xu, S., & Liu, Y. (2024) · Advanced Materials · doi:10.1002/adma.202307805 · Cited by 65
Metadata
- Authors
- Park, J., Jeon, J., Kim, B., Lee, M. S., Park, S., Lim, J., Yi, J., Lee, H., Yang, H. S., & Lee, J. Y.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-08-12
- Volume
- 30
- Issue
- 39
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3048949738
- Cited by
- 247
- References
- 3
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrically Conductive Hydrogel Nerve Guidance Conduits for Peripheral Nerve Regeneration. https://app.cochat.ai/papers/10.1002/adfm.202003759
- The paper
- Park, J., Jeon, J., Kim, B., Lee, M. S., Park, S., Lim, J., Yi, J., Lee, H., Yang, H. S., & Lee, J. Y. (2020). Electrically Conductive Hydrogel Nerve Guidance Conduits for Peripheral Nerve Regeneration. Advanced Functional Materials. https://doi.org/10.1002/adfm.202003759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.