The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Stretchable and Transparent Ionogels with High Thermoelectric Properties
Abstract
Stretchable electronic materials and devices have important applications in flexible electronic systems including wearable electronics and bioelectronics. Convenient electricity generation such as thermoelectric conversion is required for the flexible electronic systems. Hence, it is development of high‐performance thermoelectric materials with high mechanical stretchability would be highly desirable. Here, stretchable and transparent ionogels with high thermoelectric properties are demonstrated. The ionogels made of elastomeric waterborne polyurethane and 1‐ethyl‐3‐methylimidazolium dicyanamide (EMIM:DCA, an ionic liquid) are prepared by solution processing. Their mechanical and electrical properties depend on the loading of EMIM:DCA. The ionogels with 40 wt% EMIM:DCA can have a high mechanical stretchability of up to 156%, low tensile strength of 0.6 MPa, and low Young's modulus of 0.6 MPa. They also exhibit a high ionic thermovoltage of 34.5 mV K−1, high ionic conductivity of 8.4 mS cm−1 and low thermal conductivity of 0.23 W m−1 K−1 at a relative humidity of 90%. As a result, it can have a high ionic figure of merit (ZT i) of 1.3 ± 0.2. Both the thermovoltage and the ZT i value are the highest for stretchable thermoelectric materials. They can be used in ionic thermoelectric capacitors to convert heat into electricity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of electrolyte materials and compositions for electrochemical supercapacitors
Zhong, C., Deng, Y., Hu, W., Qiao, J., Zhang, L., & Zhang, J. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00303b · Cited by 3,687
Self-citationThermal runaway caused fire and explosion of lithium ion battery
Wang, Q., Ping, P., Zhao, X., Chu, G., Sun, J., & Chen, C. (2012) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.02.038 · Cited by 3,103
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Energy harvesting in wireless sensor networks: A comprehensive review
Shaikh, F. K., & Zeadally, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.010 · Cited by 1,253
Realizing high figure of merit in heavy-band p-type half-Heusler thermoelectric materials
Fu, C., Bai, S., Liu, Y., et al. (2015) · Nature Communications · doi:10.1038/ncomms9144 · Cited by 1,213
Photovoltaic solar cell technologies: analysing the state of the art
Nayak, P. K., Mahesh, S., Snaith, H. J., & Cahen, D. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0097-0 · Cited by 1,139
Materials and Optimized Designs for Human‐Machine Interfaces Via Epidermal Electronics
Jeong, J., Yeo, W., Akhtar, A., Norton, J. J. S., Kwack, Y., Li, S., Jung, S., Su, Y., Lee, W., Xia, J., et al. (2013) · Advanced Materials · doi:10.1002/adma.201301921 · Cited by 827
Self-citationGiant thermopower of ionic gelatin near room temperature
Han, C.-G., Qian, X., Li, Q., Deng, B., Zhu, Y., Han, Z., Zhang, W., Wang, W., Feng, S.-P., Chen, G., et al. (2020) · Science · doi:10.1126/science.aaz5045 · Cited by 759
Cited by
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Advances in the design and assembly of flexible thermoelectric device
Cao, T., Shi, X.-L., & Chen, Z.-G. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101003 · Cited by 387
Energy Applications of Ionic Liquids: Recent Developments and Future Prospects
Zhou, T., Gui, C., Sun, L., Hu, Y., Lyu, H., Wang, Z., Song, Z., & Yu, G. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00391 · Cited by 305
Ionogels: Preparation, Properties and Applications
Yan, C., Li, W., Liu, Z., Zheng, S., Hu, Y., Zhou, Y., Guo, J., Ou, X., Li, Q., Yu, J., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202314408 · Cited by 288
Hydro/Organo/Ionogels: “Controllable” Electromagnetic Wave Absorbers
Zhao, Z., Zhang, L., & Wu, H. (2022) · Advanced Materials · doi:10.1002/adma.202205376 · Cited by 276
Self-citation
Metadata
- Authors
- Fang, Y., Cheng, H., He, H., Wang, S., Li, J., Yue, S., Zhang, L., Du, Z., & Ouyang, J.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-09-18
- Volume
- 30
- Issue
- 51
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3087470584
- Cited by
- 274
- References
- 51
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretchable and Transparent Ionogels with High Thermoelectric Properties. https://app.cochat.ai/papers/10.1002/adfm.202004699
- The paper
- Fang, Y., Cheng, H., He, H., Wang, S., Li, J., Yue, S., Zhang, L., Du, Z., & Ouyang, J. (2020). Stretchable and Transparent Ionogels with High Thermoelectric Properties. Advanced Functional Materials. https://doi.org/10.1002/adfm.202004699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.