The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Rational Design of Soft Yet Elastic Lamellar Graphene Aerogels via Bidirectional Freezing for Ultrasensitive Pressure and Bending Sensors
Abstract
To enhance the sensitivity of graphene aerogel‐based piezoresistive sensors by weakening their compressive strength while keeping their elasticity, lightweight and lamellar graphene aerogels (LGAs) with high elasticity and satisfactory electrical conductance networks are fabricated by bidirectional‐freezing of aqueous suspensions of graphene oxide in the presence of small amounts of organic solvents, followed by lyophilizing and thermal annealing. Because of the lamellar structure of the LGA, its compressive strength along the direction perpendicular to the lamellar surface is much lower than those of both isotropic and unidirectionally aligned graphene aerogels with similar apparent densities, leading to an ultrasensitive LGA‐based piezoresistive sensor with a high sensitivity of −3.69 kPa−1 and a low detection limit of 0.15 Pa. The ultrahigh sensitivity and low detection limit of LGA‐based piezoresistive sensor contribute to detecting subtle pressure at room temperature and in liquid nitrogen with ability to detect dynamic force frequency and sound vibration. Besides, thanks to the fewer junction points between the graphene lamellae, LGAs slices can be integrated as a wide‐range and sensitive bending sensor, which can detect arbitrary bending angles from 0° to 180° with a low detection limit of 0.29°, and is efficient in detecting biosignals of wrist pulse and finger bending.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Graphene Textile Strain Sensor with Negative Resistance Variation for Human Motion Detection
Yang, Z., Pang, Y., Han, X.-L., Yang, Y., Ling, J., Jian, M., Zhang, Y., Yang, Y., & Ren, T.-L. (2018) · ACS Nano · doi:10.1021/acsnano.8b03391 · Cited by 563
Yang, J., Tang, L.-S., Bao, R.-Y., Bai, L., Liu, Z.-Y., Yang, W., Xie, B.-H., & Yang, M.-B. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta08454k · Cited by 255
Zhang, S. L., Lai, Y., He, X., Liu, R., Zi, Y., & Wang, Z. L. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201606695 · Cited by 235
Cited by
Liu, H., Xu, T., Cai, C., Liu, K., Liu, W., Zhang, M., Du, H., Si, C., & Zhang, K. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202113082 · Cited by 571
Li, Y., Yang, D., Wu, Z., Gao, F.-L., Gao, X.-Z., Zhao, H.-Y., Li, X., & Yu, Z.-Z. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108324 · Cited by 313
Self-citationYang, W., Liu, S., Wang, Z., Liu, H., Pan, C., Liu, C., & Shen, C. (2024) · Nano Energy · doi:10.1016/j.nanoen.2024.109799 · Cited by 95
Pan, W., Liang, C., Sui, Y., Wang, J., Liu, P., Zou, P., Guo, Z., Wang, F., Ren, X., & Yang, C. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204166 · Cited by 51
Self-citation
Metadata
- Authors
- Min, P., Li, X., Liu, P., Liu, J., Jia, X., Li, X., & Yu, Z.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2021-06-17
- Volume
- 31
- Issue
- 34
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3176293999
- Cited by
- 170
- References
- 4
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.