The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.
Auxetic Foam‐Based Contact‐Mode Triboelectric Nanogenerator with Highly Sensitive Self‐Powered Strain Sensing Capabilities to Monitor Human Body Movement
Abstract
The first contact‐mode triboelectric self‐powered strain sensor using an auxetic polyurethane foam, conductive fabric, and polytetrafluroethylene (PTFE) is fabricated. Utilizing the auxetic properties of the polyurethane foam, the auxetic polyurethane foam would expand into the PTFE when the foam is stretched, causing contact electrification. Due to a larger contact area between the PTFE and the foam as the foam is stretched, this device can serve effectively as a strain sensor. The sensitivity of this method is explored, and this sensor has the highest sensitivity in all triboelectric nanogenerator devices that are used previously as a strain sensor. Different applications of this strain sensor are shown, and this sensor can be used as a human body monitoring system, self‐powered scale to measure weight, and a seat belt to measure body movements inside a car seat.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Piezoelectric and triboelectric strain sensors are two other major types of stretchable strain sensors.[180–182]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [180]
Citations
Cites
Foam Structures with a Negative Poisson's Ratio
Lakes, R. (1987) · Science · doi:10.1126/science.235.4792.1038 · Cited by 3,866
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Graphene-Based Supercapacitor with an Ultrahigh Energy Density
Liu, C., Yu, Z., Neff, D., Zhamu, A., & Jang, B. Z. (2010) · Nano Letters · doi:10.1021/nl102661q · Cited by 3,207
Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn404614z · Cited by 3,058
Self-citationProgress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
Self-citationA flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Stretchable, Porous, and Conductive Energy Textiles
Hu, L., Pasta, M., La Mantia, F., Cui, L., Jeong, S., Deshazer, H. D., Choi, J. W., Han, S. M., & Cui, Y. (2010) · Nano Letters · doi:10.1021/nl903949m · Cited by 1,475
Highly conductive paper for energy-storage devices
Hu, L., Choi, J. W., Yang, Y., Jeong, S., La Mantia, F., Cui, L.-F., & Cui, Y. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0908858106 · Cited by 1,224
Graphene-based materials for flexible supercapacitors
Shao, Y., El-Kady, M. F., Wang, L. J., Zhang, Q., Li, Y., Wang, H., Mousavi, M. F., & Kaner, R. B. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00316k · Cited by 1,154
Standards and figure-of-merits for quantifying the performance of triboelectric nanogenerators
Zi, Y., Niu, S., Wang, J., Wen, Z., Tang, W., & Wang, Z. L. (2015) · Nature Communications · doi:10.1038/ncomms9376 · Cited by 897
Self-citation
Research works printed but not linked: 3
- Trung T. Q., 2016, Adv. Mater., 28, 4438
- Zi Y. L., 2015, Nat. Commun., 6
- Zhu G., 2014, Nat. Commun., 5
Cited by
Auxetic metamaterials and structures: a review
Ren, X., Das, R., Tran, P., Ngo, T. D., & Xie, Y. M. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aaa61c · Cited by 1,277
Triboelectric Nanogenerator: Structure, Mechanism, and Applications
Kim, W.-G., Kim, D.-W., Tcho, I.-W., Kim, J.-K., Kim, M.-S., & Choi, Y.-K. (2021) · ACS Nano · doi:10.1021/acsnano.0c09803 · Cited by 1,000
Mechanical metamaterials and beyond
Jiao, P., Mueller, J., Raney, J. R., Zheng, X., & Alavi, A. H. (2023) · Nature Communications · doi:10.1038/s41467-023-41679-8 · Cited by 733
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Ge, G., Zhang, Y., Shao, J., Wang, W., Si, W., Huang, W., & Dong, X. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201802576 · Cited by 579
Metadata
- Authors
- Zhang, S. L., Lai, Y., He, X., Liu, R., Zi, Y., & Wang, Z. L.
- Affiliations
- Georgia Institute of Technology (US)
- Corresponding author
- Wang, Zhong Lin
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-05-15
- Volume
- 27
- Issue
- 25
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2612352389
- Cited by
- 235
- References
- 39
- Citations by year
- 2026: 7 · 2025: 33 · 2024: 20 · 2023: 36 · 2022: 29 · 2021: 29 · 2020: 29 · 2019: 24 · 2018: 22 · 2017: 6
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Functional Materials (publishedVersion)
- Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
- King Abdullah University of Science and Technology Repository (King Abdullah University of Science and Technology) (submittedVersion)
- Funders
- King Abdullah University of Science and Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- triboelectric nanogenerator, strain sensing, self-powered sensors, triboelectric charging, polytetrafluoroethylene, conductive textiles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Auxetic Foam‐Based Contact‐Mode Triboelectric Nanogenerator with Highly Sensitive Self‐Powered Strain Sensing Capabilities to Monitor Human Body Movement. https://app.cochat.ai/papers/10.1002/adfm.201606695
- The paper
- Zhang, S. L., Lai, Y., He, X., Liu, R., Zi, Y., & Wang, Z. L. (2017). Auxetic Foam‐Based Contact‐Mode Triboelectric Nanogenerator with Highly Sensitive Self‐Powered Strain Sensing Capabilities to Monitor Human Body Movement. Advanced Functional Materials. https://doi.org/10.1002/adfm.201606695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.