Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 487

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

Super Stretchable, Self‐Healing, Adhesive Ionic Conductive Hydrogels Based on Tailor‐Made Ionic Liquid for High‐Performance Strain Sensors

Yao, Xue, Zhang, Sufeng, Qian, Liwei, Wei, Ning, Nica, Valentin, Coseri, Sergiu, Han, Fei·2022·Advanced Functional Materials

Abstract

Ionic conductive hydrogels (ICHs) integrate the conductive performance and soft nature of tissue‐like materials to imitate the features of human skin with mechanical and sensory traits; thus, they are considered promising substitutes for conventional rigid metallic conductors when fabricating human‐motion sensors. However, the simultaneous incorporation of excellent stretchability, toughness, ionic conductivity, self‐healing, and adhesion via a simple method remains a grand challenge. Herein, a novel ICH platform is proposed by designing a phenylboronic acid‐ionic liquid (PBA‐IL) with multiple roles that simultaneously realize the highly mechanical, electrical, and versatile properties. This elaborately designed semi‐interpenetrating network ICH is fabricated via a facile one‐step approach by introducing cellulose nanofibrils (CNFs) into the PBA‐IL/acrylamide cross‐linked network. Ingeniously, the dynamic boronic ester bonds and physical interactions (hydrogen bonds and electrostatic interactions) of the cross‐linked network endow these hydrogels with remarkable stretchability (1810 ± 38%), toughness (2.65 ± 0.03 MJ m−3), self‐healing property (92 ± 2% efficiency), adhesiveness, and transparency. Moreover, the construction of this material shows that CNFs can synergistically enhance mechanical performance and conductivity. The wide working strain range (≈1000%) and high sensitivity (GF = 8.36) make this ICH a promising candidate for constructing the next generation of gel‐based strain sensor platforms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.202204565

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Cited by

See all 487

Metadata

Authors
Yao, X., Zhang, S., Qian, L., Wei, N., Nica, V., Coseri, S., & Han, F.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2022-06-08
Volume
32
Issue
33
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W4281916753
Cited by
487
References
63
FWCI
28.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Super Stretchable, Self‐Healing, Adhesive Ionic Conductive Hydrogels Based on Tailor‐Made Ionic Liquid for High‐Performance Strain Sensors. https://app.cochat.ai/papers/10.1002/adfm.202204565
The paper
Yao, X., Zhang, S., Qian, L., Wei, N., Nica, V., Coseri, S., & Han, F. (2022). Super Stretchable, Self‐Healing, Adhesive Ionic Conductive Hydrogels Based on Tailor‐Made Ionic Liquid for High‐Performance Strain Sensors. Advanced Functional Materials. https://doi.org/10.1002/adfm.202204565

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.