Stretchable, Transparent, and Self‐Patterned Hydrogel‐Based Pressure Sensor for Human Motions Detection
Abstract
In this study, a binary networked conductive hydrogel is prepared using acrylamide and polyvinyl alcohol. Based on the obtained hydrogel, an ultrastretchable pressure sensor with biocompatibility and transparency is fabricated cost effectively. The hydrogel exhibits impressive stretchability (>500%) and superior transparency (>90%). Furthermore, the self‐patterned microarchitecture on the hydrogel surface is beneficial to achieve high sensitivity (0.05 kPa −1 for 0–3.27 kPa). The hydrogel‐based pressure sensor can precisely monitor dynamic pressures (3.33, 5.02, and 6.67 kPa) with frequency‐dependent behavior. It also shows fast response (150 ms), durable stability (500 dynamic cycles), and negligible current variation (6%). Moreover, the sensor can instantly detect both tiny (phonation, airflowing, and saliva swallowing) and robust (finger and limb motions) physiological activities. This work presents insights into preparing multifunctional hydrogels for mechanosensory electronics.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
DN conductive hydrogel (acrylamide/PVA with MBAA) has high stretchability (>500%), high transparency (>90%), good adhesion, and biocompatibility.
“Ge et al. [205] prepared a DN conductive hydrogel with high stretchability (> 500%), high transparency (> 90%), good adhesion, and biocompatibility”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [205]
High sensitivity of pressure of 0.05 kPa−1 under 0-3.27 kPa enables successful application in the detection of speech signals, airflow, and limb movements.
“The high sensitivity of pressure of 0.05 kPa−1 under 0–3.27 kPa enables its successful application in the detection of speech signals, airflow, and limb movements”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as [205]
Cites
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825 · see citing works
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063 · see citing works
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695 · see citing works
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519 · see citing works
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435 · see citing works
Carbonized Silk Nanofiber Membrane for Transparent and Sensitive Electronic Skin
Wang, Q., Jian, M., Wang, C., & Zhang, Y. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605657 · Cited by 549 · see citing works
Self-citationHu, W., Niu, X., Zhao, R., & Pei, Q. (2013) · Applied Physics Letters · doi:10.1063/1.4794143 · Cited by 332 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236 · see citing works
“With acrylamide and PVA as the primary materials, and using N,N-methylenebisacrylamide (MBAA) crosslinking, Ge et al. [205] prepared a DN conductive hydrogel with high stretchability (> 500%), high transparency (> 90%), good adhesion, and biocompatibility.”
MethodWu, J., Wu, Z., Han, S., Yang, B.-R., Gui, X., Tao, K., Liu, C., Miao, J., & Norford, L. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17437 · Cited by 225 · see citing works
Zhang, Y., Zhang, R., & Tao, Y. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.121300 · Cited by 27 · see citing works
Self-citation
- Authors
- Ge, G., Zhang, Y., Shao, J., Wang, W., Si, W., Huang, W., & Dong, X.
- Affiliations
- Nanjing Tech University (CN)
- Liaocheng University (CN)
- Northwestern Polytechnical University (CN)
- Corresponding author
- Huang, Wei
- Dong, Xiaochen
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-06-21
- Volume
- 28
- Issue
- 32
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2809351981
- Cited by
- 579
- References
- 7
- Citations by year
- 2026: 30 · 2025: 55 · 2024: 62 · 2023: 88 · 2022: 99 · 2021: 103 · 2020: 81 · 2019: 56 · 2018: 4
- FWCI
- 24.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Functional Materials (publishedVersion)
- Funders
- National Natural Science Foundation of China (61525402, 61775095, 61728401, 61775089)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- conductive hydrogels, transparent hydrogels, human motion detection, biocompatible electronics, wearable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review