Cited by 579Advanced Sensor and Energy Harvesting MaterialsHydrogels: synthesis, properties, applicationsNanomaterials and Printing Technologies

Stretchable, Transparent, and Self‐Patterned Hydrogel‐Based Pressure Sensor for Human Motions Detection

Ge, Gang, Zhang, Yizhou, Shao, Jinjun, Wang, Wenjun, Si, Weili, Huang, Wei, Dong, Xiaochen·2018·Advanced Functional Materials

Abstract

In this study, a binary networked conductive hydrogel is prepared using acrylamide and polyvinyl alcohol. Based on the obtained hydrogel, an ultrastretchable pressure sensor with biocompatibility and transparency is fabricated cost effectively. The hydrogel exhibits impressive stretchability (>500%) and superior transparency (>90%). Furthermore, the self‐patterned microarchitecture on the hydrogel surface is beneficial to achieve high sensitivity (0.05 kPa −1 for 0–3.27 kPa). The hydrogel‐based pressure sensor can precisely monitor dynamic pressures (3.33, 5.02, and 6.67 kPa) with frequency‐dependent behavior. It also shows fast response (150 ms), durable stability (500 dynamic cycles), and negligible current variation (6%). Moreover, the sensor can instantly detect both tiny (phonation, airflowing, and saliva swallowing) and robust (finger and limb motions) physiological activities. This work presents insights into preparing multifunctional hydrogels for mechanosensory electronics.

Integrity signals

Registry

Crossref · 10.1002/adfm.201802576

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • DN conductive hydrogel (acrylamide/PVA with MBAA) has high stretchability (>500%), high transparency (>90%), good adhesion, and biocompatibility.

    “Ge et al. [205] prepared a DN conductive hydrogel with high stretchability (> 500%), high transparency (> 90%), good adhesion, and biocompatibility”
  • High sensitivity of pressure of 0.05 kPa−1 under 0-3.27 kPa enables successful application in the detection of speech signals, airflow, and limb movements.

    “The high sensitivity of pressure of 0.05 kPa−1 under 0–3.27 kPa enables its successful application in the detection of speech signals, airflow, and limb movements”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ge, G., Zhang, Y., Shao, J., Wang, W., Si, W., Huang, W., & Dong, X.
Affiliations
  • Nanjing Tech University (CN)
  • Liaocheng University (CN)
  • Northwestern Polytechnical University (CN)
Corresponding author
  • Huang, Wei
  • Dong, Xiaochen
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2018-06-21
Volume
28
Issue
32
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2809351981
Cited by
579
References
7
Citations by year
2026: 30 · 2025: 55 · 2024: 62 · 2023: 88 · 2022: 99 · 2021: 103 · 2020: 81 · 2019: 56 · 2018: 4
FWCI
24.39
Type
journal article
Language
en
Open access
closed
Locations
Advanced Functional Materials (publishedVersion)
Funders
National Natural Science Foundation of China (61525402, 61775095, 61728401, 61775089)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
conductive hydrogels, transparent hydrogels, human motion detection, biocompatible electronics, wearable sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review