The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Bio‐Origami Hydrogel Scaffolds Composed of Photocrosslinked PEG Bilayers
Abstract
We describe the self‐folding of photopatterned poly (ethylene glycol) (PEG)‐based hydrogel bilayers into curved and anatomically relevant micrometer‐scale geometries. The PEG bilayers consist of two different molecular weights (MWs) and are photocrosslinked en masse using conventional photolithography. Self‐folding is driven by differential swelling of the two PEG bilayers in aqueous solutions. We characterize the self‐folding of PEG bilayers of varying composition and develop a finite element model which predicts radii of curvature that are in good agreement with empirical results. Since we envision the utility of bio‐origami in tissue engineering, we photoencapsulate insulin secreting β‐TC‐6 cells within PEG bilayers and subsequently self‐fold them into cylindrical hydrogels of different radii. Calcein AM staining and ELISA measurements are used to monitor cell proliferation and insulin production respectively, and the results indicate cell viability and robust insulin production for over eight weeks in culture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Cited by
Momeni, F., M.Mehdi Hassani.N, S., Liu, X., & Ni, J. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.02.068 · Cited by 1,165
Using origami design principles to fold reprogrammable mechanical metamaterials
Silverberg, J. L., Evans, A. A., McLeod, L., Hayward, R. C., Hull, T., Santangelo, C. D., & Cohen, I. (2014) · Science · doi:10.1126/science.1252876 · Cited by 1,011
Mannoor, M. S., Jiang, Z., James, T., Kong, Y. L., Malatesta, K. A., Soboyejo, W. O., Verma, N., Gracias, D. H., & McAlpine, M. C. (2013) · Nano Letters · doi:10.1021/nl4007744 · Cited by 874
Self-citationDesign, fabrication and control of origami robots
Rus, D., & Tolley, M. T. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0009-8 · Cited by 641
González-Henríquez, C. M., Sarabia-Vallejos, M. A., & Rodriguez-Hernandez, J. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.03.001 · Cited by 562
Metadata
- Authors
- Jamal, M., Kadam, S. S., Xiao, R., Jivan, F., Onn, T., Fernandes, R., Nguyen, T. D., & Gracias, D. H.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2013-08
- Volume
- 2
- Issue
- 8
- Pages
- 1142-1150
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2104709595
- Cited by
- 270
- References
- 2
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bio‐Origami Hydrogel Scaffolds Composed of Photocrosslinked PEG Bilayers. https://app.cochat.ai/papers/10.1002/adhm.201200458
- The paper
- Jamal, M., Kadam, S. S., Xiao, R., Jivan, F., Onn, T., Fernandes, R., Nguyen, T. D., & Gracias, D. H. (2013). Bio‐Origami Hydrogel Scaffolds Composed of Photocrosslinked PEG Bilayers. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201200458
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.