The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Design of Hydrogels for Biomedical Applications
Abstract
Hydrogels are considered key tools for the design of biomaterials, such as wound dressings, drug reservoirs, and temporary scaffolds for cells. Despite their potential, conventional hydrogels have limited applicability under wet physiological conditions because they suffer from the uncontrollable temporal change in shape: swelling takes place immediately after the installation. Swollen hydrogels easily fail under mechanical stress. The morphological change may cause not only the slippage from the installation site but also local nerve compression. The design of hydrogels that can retain their original shape and mechanical properties in an aqueous environment is, therefore, of great importance. On the one hand, the controlled degradation of used hydrogels has to be realized in some biomedical applications. This Progress Report provides a brief overview of the recent progress in the development of hydrogels for biomedical applications. Practical approaches to control the swelling properties of hydrogels are discussed. The designs of hydrogels with controlled degradation properties as well as the theoretical models to predict the degradation behavior are also introduced. Moreover, current challenges and limitation toward biomedical applications are discussed, and future directions are offered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Sakai, T., Matsunaga, T., Yamamoto, Y., Ito, C., Yoshida, R., Suzuki, S., Sasaki, N., Shibayama, M., & Chung, U.-I. (2008) · Macromolecules · doi:10.1021/ma800476x · Cited by 1,274
Self-citation“Nonswellable” Hydrogel Without Mechanical Hysteresis
Kamata, H., Akagi, Y., Kayasuga-Kariya, Y., Chung, U.-I., & Sakai, T. (2014) · Science · doi:10.1126/science.1247811 · Cited by 669
Self-citation
Cited by
Abasalizadeh, F., Moghaddam, S. V., Alizadeh, E., akbari, E., Kashani, E., Fazljou, S. M. B., Torbati, M., & Akbarzadeh, A. (2020) · Journal of Biological Engineering · doi:10.1186/s13036-020-0227-7 · Cited by 608
Bioinspired fabrication of high strength hydrogels from non-covalent interactions
Wang, W., Zhang, Y., & Liu, W. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.04.001 · Cited by 517
Zhu, J., Li, F., Wang, X., Yu, J., & Wu, D. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18927 · Cited by 373
Metadata
- Authors
- Kamata, H., Li, X., Chung, U., & Sakai, T.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2015-05-03
- Volume
- 4
- Issue
- 16
- Pages
- 2360-2374
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2056415089
- Cited by
- 162
- References
- 4
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of Hydrogels for Biomedical Applications. https://app.cochat.ai/papers/10.1002/adhm.201500076
- The paper
- Kamata, H., Li, X., Chung, U., & Sakai, T. (2015). Design of Hydrogels for Biomedical Applications. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201500076
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.