The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Toward a Molecular Understanding of the Antibacterial Mechanism of Copper‐Bearing Titanium Alloys against Staphylococcus aureus
Open accessAbstract
The antibacterial mechanism of the Cu‐containing materials has not been fully understood although such understanding is crucial for the sustained clinical use of Cu‐containing antibacterial materials such as bone implants. The aim of this study is to investigate the molecular mechanisms by which the Gram‐positive Staphylococcus aureus is inactivated through Cu‐bearing titanium alloys (Ti6Al4V5Cu). Cu ions released from the alloys are found to contribute to lethal damage of bacteria. They destroy the permeability of the bacterial membranes, resulting in the leakage of reducing sugars and proteins from the cells. They also promote the generation of bacteria‐killing reactive oxygen species (ROS). The ROS production is confirmed by several assays including fluorescent staining of intracellular oxidative stress, detection of respiratory chain activity, and measurement of the levels of lipid peroxidation, catalase, and glutathione. Furthermore, the released Cu ions show obvious genetic toxicity by interfering the replication of nuc (species‐specific) and 16SrRNA genes, but with no effect on the genome integrity. All of these effects lead to the antibacterial effect of Ti6Al4V5Cu. Collectively, our work reconciles the conflicting antibacterial mechanisms of Cu‐bearing metallic materials or nanoparticles reported in the literature and highlights the potential use of Ti6Al4V5Cu alloys in inhibiting bacterial infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevention of pin tract infection with titanium‐copper alloys
Shirai, T., Tsuchiya, H., Shimizu, T., Ohtani, K., Zen, Y., & Tomita, K. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31412 · Cited by 199
Antimicrobial metallic copper surfaces kill Staphylococcus haemolyticus via membrane damage
Santo, C. E., Quaranta, D., & Grass, G. (2012) · MicrobiologyOpen · doi:10.1002/mbo3.2 · Cited by 195
Cited by
Wang, R., Shi, M., Xu, F., Qiu, Y., Zhang, P., Shen, K., Zhao, Q., Yu, J., & Zhang, Y. (2020) · Nature Communications · doi:10.1038/s41467-020-18267-1 · Cited by 441
Self-citationAntimicrobial Copper-Based Materials and Coatings: Potential Multifaceted Biomedical Applications
Mitra, D., Kang, E.-T., & Neoh, K. G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17815 · Cited by 322
Hemostatic and antibacterial calcium–copper zeolite gauze for infected wound healing
Wang, M., Zhang, W., Wang, C., Xiao, L., Yu, L., & Fan, J. (2024) · RSC Advances · doi:10.1039/d3ra06070e · Cited by 20
Wu, Y., Cai, Z., Zhang, Y., Zheng, Y., Liao, L., & Jia, Z. (2026) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.12.018 · Cited by 7
“An iodonitrotetrazolium chloride (INT) assay was employed for assessing the respiratory chain dehydrogenase activity [35].”
Self-citation
Metadata
- Authors
- Li, M., Ma, Z., Zhu, Y., Xia, H., Yao, M., Chu, X., Wang, X., Yang, K., Yang, M., Zhang, Y., & Mao, C.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2015-12-22
- Volume
- 5
- Issue
- 5
- Pages
- 557-566
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2207576671
- Cited by
- 208
- References
- 2
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward a Molecular Understanding of the Antibacterial Mechanism of Copper‐Bearing Titanium Alloys against Staphylococcus aureus. https://app.cochat.ai/papers/10.1002/adhm.201500712
- The paper
- Li, M., Ma, Z., Zhu, Y., Xia, H., Yao, M., Chu, X., Wang, X., Yang, K., Yang, M., Zhang, Y., & Mao, C. (2016). Toward a Molecular Understanding of the Antibacterial Mechanism of Copper‐Bearing Titanium Alloys against Staphylococcus aureus. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201500712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.