Freestanding, Fiber-Based, Wearable Temperature Sensor with Tunable Thermal Index for Healthcare Monitoring
Abstract
Fiber-based sensors integrated on textiles or clothing systems are required for the next generation of wearable electronic platforms. Fiber-based physical sensors are developed, but the development of fiber-based temperature sensors is still limited. Herein, a new approach to develop wearable temperature sensors that use freestanding single reduction graphene oxide (rGO) fiber is proposed. A freestanding and wearable temperature-responsive rGO fiber with tunable thermal index is obtained using simple wet spinning and a controlled graphene oxide reduction time. The freestanding fiber-based temperature sensor shows high responsivity, fast response time (7 s), and good recovery time (20 s) to temperature. It also maintains its response under an applied mechanical deformation. The fiber device fabricated by means of a simple process is easily integrated into fabric such as socks or undershirts and can be worn by a person to monitor the temperature of the environment and skin temperature without interference during movement and various activities. These results demonstrate that the freestanding fiber-based temperature sensor has great potential for fiber-based wearable electronic platforms. It is also promising for applications in healthcare and biomedical monitoring.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The most flexible optical fiber variants can monitor the joints of the human body.
“The most flexible variants are also capable of monitoring the joints of the human body [201,202].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [202]
The citation lists haven’t been fetched yet
References 51 · Cited by 232
- Authors
- Trung, T. Q., Le, H. S., Dang, T. M. L., Ju, S., Park, S. Y., & Lee, N.
- Affiliations
- Sungkyunkwan University (KR)
- Center for Advanced Chemistry Institute of Research and Development Duy Tan University 03 Quang Trung Da Nang 550000 Vietnam
- Seoul National University (KR)
- Kyonggi University (KR)
- Corresponding author
- Park, Sang Yoon
- Lee, Nae‐Eung
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-05-11
- Volume
- 7
- Issue
- 12
- Pages
- e1800074-e1800074
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2801434406
- Cited by
- 232
- References
- 51
- Citations by year
- 2026: 8 · 2025: 28 · 2024: 30 · 2023: 41 · 2022: 32 · 2021: 47 · 2020: 30 · 2019: 12 · 2018: 4
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Healthcare Materials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Research Foundation of Korea
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Materials Chemistry › Graphene research and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Keywords
- wearable temperature sensors, wet spinning, graphene oxide reduction, skin temperature monitoring, mechanical deformation, textile-integrated electronics, healthcare monitoring
- MeSH terms
- Wearable Electronic Devices, Adult, Humans, Male, Monitoring, Physiologic, Temperature, Textiles, Thermometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review