The Current State of Optical Sensors in Medical Wearables
Open accessAbstract
Optical sensors play an increasingly important role in the development of medical diagnostic devices. They can be very widely used to measure the physiology of the human body. Optical methods include PPG, radiation, biochemical, and optical fiber sensors. Optical sensors offer excellent metrological properties, immunity to electromagnetic interference, electrical safety, simple miniaturization, the ability to capture volumes of nanometers, and non-invasive examination. In addition, they are cheap and resistant to water and corrosion. The use of optical sensors can bring better methods of continuous diagnostics in the comfort of the home and the development of telemedicine in the 21st century. This article offers a large overview of optical wearable methods and their modern use with an insight into the future years of technology in this field.
Verified 2026-10-09 · 2 references not checked yet
AI snapshot
Written from the paper’s full text.
TL;DR
This review surveys optical sensors for medical wearables across photoplethysmography, radiation, optical fiber, and biochemical sensing. It argues these sensors offer non-invasive, miniaturizable, electromagnetically immune monitoring, while noting persistent challenges in ambient light, penetration depth, stability, and biocompatibility.
Key findings
- Optical sensors are already significant in wearables: about 15% of the wearable-device market is based on optical sensors, and the wearable medical market is projected to grow by around 26.4% worldwide to $195.57 billion between 2020 and 2027.
- PPG supports diverse vital-sign monitoring: a smartwatch PPG/accelerometer algorithm detected atrial fibrillation with 98% sensitivity and 90.2% specificity, and PPG-based glucose estimation achieved maximum correlation coefficients of 0.91 and 0.86 with a standard prediction error of approximately 6.16 mg/dl.
- Optical fiber and radiation sensors report high accuracy in selected studies: POF smart-bed sensors had absolute errors below 1 rpm and 2 bpm, FBG temperature sensors reached 150 pm/°C (almost 15 times higher than bare FBG), and indirect core body temperature evaluation achieved ±0.03 °C accuracy.
- The review organizes the field into four areas—photoplethysmography, radiation sensors, fiber sensors, and biochemical analyzers—and concludes that optical sensors are highly preferred for wearable electronics and telemedicine, despite remaining technical and material limitations.
Methods
- Narrative review of optical sensors and devices related to human physiology, identifying four main areas: photoplethysmography, radiation sensors, fiber sensors, and biochemical analyzers.
- The paper synthesizes selected and promising sensor types and applications, with summary tables listing sensor type, application, sensing element, key parameters, and references.
- No primary experimental sample, systematic search strategy, or quantitative meta-analysis is reported; findings are compiled from cited studies and commercial/technical examples.
Limitations
- The paper states that ambient light interference, short penetration depth into skin and other bioliquids, sensor stability issues (especially electrochemical passivation and biofouling), optical fiber damage during use, uncertain nanomaterial biocompatibility/toxicity, flexible battery and energy-management needs, and patient-data privacy remain challenges.
- Evident from the text: as a narrative review, it does not report a systematic search protocol, inclusion criteria, risk-of-bias assessment, or pooled quantitative synthesis.
- Evident from the text: reported performance figures come from heterogeneous cited studies and devices, so they are not directly comparable or independently validated within this review.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 201 cited sources checked · 0 supported · 0 flagged
- Premisecitation
Microelectronic technologies may ultimately reach their limits inherent in low-frequency electromagnetic fields.
“As microelectronic technologies are driven by requirements for wearable devices towards higher sensitivity, faster response, better robustness, and higher integration, they may ultimately reach their limits, which are inherent in the very nature of low-frequency electromagnetic fields [26,27,28,29,30,31].”
Quote in the paperSubstantial claim0 of 6 sources checked- cites [26] Kang, 2014, Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system, Nature source
Not checked in the free run.
- cites [27] Yin, 2016, Efficient and mechanically robust stretchable organic light-emitting devices by a laser-programmable buckling process, Nat. Commun. source
Not checked in the free run.
- cites [28] Miyamoto, 2017, Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes, Nat. Nanotechnol. source
Not checked in the free run.
- cites [29] Takei, 2010, Nanowire active-matrix circuitry for low-voltage macroscale artificial skin, Nat. Mater. source
Not checked in the free run.
- cites [30] Larson, 2016, Highly stretchable electroluminescent skin for optical signaling and tactile sensing, Science source
Not checked in the free run.
- cites [31] Kim, 2018, A bioinspired flexible organic artificial afferent nerve, Science source
Not checked in the free run.
- Premisecitation
Blood oxygenation is proportional to reflected red light (622-780 nm) and IR (780-2400 nm).
“Blood oxygenation is proportional to reflected red light (622–780 nm) and IR (780–2400 nm) [87].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [87] Chang, C.C., Wu, C.T., Choi, B.I., and Fang, T.J. (2019). MW-PPG sensor: An on-chip spectrometer approach. Sensors, 19. source
Not checked in the free run.
- Premisecitation
HR measurement can predict cardiovascular morbidity and mortality in a reliable and easily accessible way.
“It can predict cardiovascular morbidity and mortality in a very reliable and easily accessible way.”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Efforts are made to measure BP based on pulse wave transition time (PTT) from PPG curve shape or time shift between ECG and PPG in periphery.
“Thus, great efforts are made to measure BP based on the pulse wave transition time (PTT), whether from the shape of the PPG curve or the time shift between ECG and PPG in the periphery [44].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [44] Dias, D., and Paulo Silva Cunha, J. (2018). Wearable Health Devices—Vital Sign Monitoring, Systems and Technologies. Sensors, 18. source
Not checked in the free run.
- Premisereasoning
To minimize artifacts, modern PPG chips include accelerometric sensors or multiple optical paths using two photodiodes.
“To minimize these artifacts, accelerometric sensors or multiple optical paths using two photodiodes are therefore included in modern PPG chips.”
Quote in the paperNot a substantial claim
- Premisecitation
Age, gender, and pathological conditions can cause various reflections, scattering, and light absorption.
“Age, gender, and pathological conditions can cause various reflections, scattering, and light absorption [73].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [73] Tarar, A.A., Mohammad, U., and Srivastava, S.K. (2020). Wearable skin sensors and their challenges: A review of transdermal, optical, and mechanical sensors. Biosensors, 10. source
Not checked in the free run.
- Premisecitation
For reliable detection in skin layers, LEDs and photodiodes must ideally operate in wavelength range of absorption peaks of blood hemoglobin and deoxyhemoglobin, between 540 and 570 nm.
“For reliable detection in these skin layers, the used LEDs (respectively, light sources) and photodiodes PDs must ideally operate in the wavelength range of the absorption peaks of blood hemoglobin and deoxyhemoglobin, i.e., between 540 and 570 nm [77].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [77] Rundo, F., Conoci, S., Ortis, A., and Battiato, S. (2018). An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment. Sensors, 18. source
Not checked in the free run.
- Premisecitation
Transmission PPG configurations increase the perfusion index by 40 dB to 60 dB.
“Transmission PPG configurations increase the perfusion index by 40 dB to 60 dB [45,62].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [45] Ray, D., Collins, T., Woolley, S., and Ponnapalli, P. (2021). A Review of Wearable Multi-wavelength Photoplethysmography. IEEE Rev. Biomed. Eng., 1.
Not checked in the free run.
- cites [62] Kyriacou, P.A., and May, J.M. (2022). Photoplethysmography: New trends and future directions. Photoplethysmography, Elsevier. source
Not checked in the free run.
- Premisenone given
Non-invasive and continuous measurement of biomarkers such as sodium, chlorine, potassium, lactate, calcium, glucose, ammonia, ethanol, urea, cortisol, and various neuropeptides and cytokinesis is possible from sweat or saliva.
“Non-invasive and continuous measurement of biomarkers such as sodium, chlorine, potassium, lactate, calcium, glucose, ammonia, ethanol, urea, cortisol, and various neuropeptides and cytokinesis is possible from sweat or saliva.”
Quote in the paperNot a substantial claim - Premisenone given
PPG measurement can be performed in all parts of human body with sufficient availability of blood vessels and sufficient pulsating component, especially using reflective method.
“The PPG measurement can be performed in all parts of the human body, which provides sufficient availability of blood vessels and a sufficient pulsating component, especially when using the reflective method.”
Quote in the paperNot a substantial claim - Premisenone given
Optical sensors allow implementation of distributed sensors that can read and transmit quantities directly.
“Other significant advantages include the possibility of implementing distributed sensors, which allow quantities not only to be read but also to be transmitted directly.”
Quote in the paperNot a substantial claim - Premisecitation
Limitations of microelectronic technologies can be avoided by using photons as a signal carrier.
“These limitations can be avoided by using photons as a signal carrier [32].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [32] Miller, 2000, Rationale and challenges for optical interconnects to electronic chips, Proc. IEEE source
Not checked in the free run.
- Interpretationcitation
Measurement problem of hydration while moving can be solved with optical sensors together with a set of sensors measuring indirect hydration.
“Lack of drinking can be easily detected from urine or blood, but collection cannot be performed while moving, but this measurement problem can be solved with the help of optical sensors together with a set of sensors that allow to measure the indirect method of hydration [46].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] Ozana, 2014, Improved noncontact optical sensor for detection of glucose concentration and indication of dehydration level, Biomed. Opt. Express source
Not checked in the free run.
- Premisecitation
These BP algorithms are adapted to analyze PPG signals acquired in different parts of the body and with different sensor topologies.
“In addition, these algorithms are adapted to analyze PPG signals acquired in different parts of the body and with different sensor topologies [117].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [117] Sola, J., Bertschi, M., and Krauss, J. (2022, January 26). Measuring Pressure. Available online: https://www.embs.org/pulse/articles/optical-blood-pressure-monitoring/.
Not checked in the free run.
- Premisecitation
Many algorithms are known where systolic and diastolic BP are estimated from the shape of the PPG curve.
“Many algorithms are known where systolic and diastolic BP are estimated from the shape of the PPG curve [55,102].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [55] Elgendi, 2019, The use of photoplethysmography for assessing hypertension, NPJ Digit. Med. source
Not checked in the free run.
- cites [102] Hosanee, M., Chan, G., Welykholowa, K., Cooper, R., Kyriacou, P.A., Zheng, D., Allen, J., Abbott, D., Menon, C., and Lovell, N.H. (2020). Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring. J. Clin. Med., 9. source
Not checked in the free run.
- Premisecitation
Core body temperature can be determined by indirect measurement using several signal processing methods.
“However, the determination of core body temperature by indirect measurement can be accomplished using several signal processing methods [144,145].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [144] Chen, H.Y., Chen, A., and Chen, C. (2020). Investigation of the impact of infrared sensors on core body temperature monitoring by comparing measurement sites. Sensors, 20. source
Not checked in the free run.
- cites [145] Hymczak, H., Gołąb, A., Mendrala, K., Plicner, D., Darocha, T., Podsiadło, P., Hudziak, D., Gocoł, R., and Kosiński, S. (2021). Core temperature measurement—principles of correct measurement, problems, and complications. Int. J. Environ. Res. Public Health, 18. source
Not checked in the free run.
- Premisecitation
A muscle contraction sensor has been developed to measure signals from intact muscles for robotics and prosthetics.
“A muscle contraction sensor has also been developed to measure signals from intact muscles, which can then be used in robotics and prosthetics [39].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [39] Bansal, 2015, Wearable Organic Optoelectronic Sensors for Medicine, Adv. Mater. source
Not checked in the free run.
- Premisecitation
Skin surface temperature depends on vascularity and the anatomical location where the measurement is performed.
“The surface temperature of the skin depends on the vascularity and anatomical location where the measurement is performed [142].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [142] Neves, 2017, Effect of body fat and gender on body temperature distribution, J. Therm. Biol. source
Not checked in the free run.
- Premisecitation
Researchers estimated blood glucose levels from green and red light on fingers using machine learning and random forest regression.
“The researchers tried to estimate blood glucose levels [91] from green and red light on fingers using machine learning and a random forest regression algorithm.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [91] Gupta, S.S., Hossain, S., Haque, C.A., and Kim, K.-D. (2020, January 21–23). In-Vivo Estimation of Glucose Level Using PPG Signal. Proceedings of the 2020 International Conference on Information and Communication Technology Convergence (ICTC), Jeju, Korea. source
Not checked in the free run.
- Premisecitation
The forehead and chest are the best places to determine body temperature.
“The best places to determine body temperature, the forehead and chest, were resolved experimentally [143].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [143] Shajkofci, 2021, Correction of human forehead temperature variations measured by non-contact infrared thermometer, IEEE Sens. J.
Not checked in the free run.
- Premisecitation
Another approach extracted blood glucose levels by applying four wavelengths of light on the wrist using partial least squares algorithm as calibration.
“The next approach extracted blood glucose levels by applying four wavelengths of light (green, red, and two IRs) on the wrist using a partial least squares algorithm as the calibration [92].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Rachim, 2019, Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring, Sensors Actuators B Chem. source
Not checked in the free run.
- Premisecitation
Indirect core body temperature evaluation can achieve a high accuracy of ±0.03 °C.
“From these data, the internal core body temperature is evaluated with a high accuracy of ±0.03 °C [129,140,146,147,148,149].”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [129] Hussain, 2021, Proper use of noncontact infrared thermometry for temperature screening during COVID-19, Sci. Rep. source
Not checked in the free run.
- cites [140] Chen, 2019, Thermometry and interpretation of body temperature, Biomed. Eng. Lett. source
Not checked in the free run.
- cites [146] Bernard, 2013, Infrared camera assessment of skin surface temperature—Effect of emissivity, Phys. Medica source
Not checked in the free run.
- cites [147] Shourav, 2021, Estimation of core body temperature by near-infrared imaging of vein diameter change in the dorsal hand, Biomed. Opt. Express source
Not checked in the free run.
- cites [148] Wang, Q., Zhou, Y., Ghassemi, P., McBride, D., Casamento, J.P., and Pfefer, T.J. (2022). Infrared thermography for measuring elevated body temperature: Clinical accuracy, calibration, and evaluation. Sensors, 22. source
Not checked in the free run.
- cites [149] Foster, 2021, Non-contact infrared assessment of human body temperature: The journal Temperature toolbox, Temperature source
Not checked in the free run.
- Premisecitation
Core temperature changes are affected by circadian rhythms.
“Core temperature changes are affected by circadian rhythms.”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [135] Costa, 2018, Daily rhythm of skin temperature of women evaluated by infrared thermal imaging, J. Therm. Biol. source
Not checked in the free run.
- cites [136] Baschieri, 2021, Circadian and state-dependent core body temperature in people with spinal cord injury, Spinal Cord source
Not checked in the free run.
- cites [137] Baker, 2007, Circadian rhythms, sleep, and the menstrual cycle, Sleep Med. source
Not checked in the free run.
- cites [138] Honma, 2013, [Circadian rhythms in body temperature and sleep], Nihon Rinsho.
Not checked in the free run.
- cites [139] Edwards, 2009, Zeitgeber-effects of exercise on human circadian rhythms: What are alternative approaches to investigating the existence of a phase-response curve to exercise?, Biol. Rhythm Res. source
Not checked in the free run.
- cites [140] Chen, 2019, Thermometry and interpretation of body temperature, Biomed. Eng. Lett. source
Not checked in the free run.
- Premisecitation
Monitoring cardiorespiratory activities using a PPG signal is a well-established non-invasive technique.
“Monitoring cardiorespiratory activities using a PPG signal is a well-established non-invasive technique [44,93].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [44] Dias, D., and Paulo Silva Cunha, J. (2018). Wearable Health Devices—Vital Sign Monitoring, Systems and Technologies. Sensors, 18. source
Not checked in the free run.
- cites [93] Scully, 2012, Physiological parameter monitoring from optical recordings with a mobile phone, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
- Premisecitation
In a study by Liu et al., using three wavelengths instead of single-wavelength PPG increased accuracy about two times.
“For example, in a study by Liu et al., where instead of using a single wavelength PPG, three wavelengths were used, the accuracy was increased about two times [114].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [114] Liu, 2016, Multi-wavelength photoplethysmography method for skin arterial pulse extraction, Biomed. Opt. Express. source
Not checked in the free run.
- Premisenone given
The correlation of PTT with systolic and diastolic blood pressure is high.
“The correlation of PTT with systolic and diastolic blood pressure is high.”
Quote in the paperNot a substantial claim - Premisecitation
The basic principle of these radiation sensors is to measure the intensity of emitted radiation in a limited infrared spectrum.
“The basic principle of sensing these sensors use is to measure the intensity of emitted radiation in a limited infrared spectrum [132,133].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [132] Law, 2018, Infrared Thermography, RILEM State-of-the-Art Reports
Not checked in the free run.
- cites [133] Sanchez-Marin, F.J. (2010, January 18–20). A new method for determining the emissivity of the human skin in vivo. Proceedings of the 2010 4th International Conference on Bioinformatics and Biomedical Engineering, Chengdu, China. source
Not checked in the free run.
- Premisecitation
This anisotropy can be detected using a surface light source and detectors placed longitudinally and perpendicular to the muscle fiber, representing a modification of the PPG sensor.
“This anisotropy can be detected utilizing a surface light source and detectors placed longitudinally and perpendicular to the muscle fiber, which represents only a certain modification of the PPG sensor [126,127].”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Internal body temperature differs from peripheral body temperature such as that of limbs.
“Internal body temperature is different from the body temperature of peripherals such as limbs, and the boundary between them is indeterminate and varies with ambient temperature [134].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [134] Ogoina, 2011, Fever, fever patterns and diseases called “fever”—A review, J. Infect. Public Health source
Not checked in the free run.
- Premisecitation
A hybrid plasmonic microfiber knot resonator embedded in a PDMS membrane has high sensitivity for sensing wrist/finger pulse and respiration.
“In addition, experiments with a novel photonic-based platform—a hybrid plasmonic microfiber knot resonator embedded in a PDMS membrane—were performed and high sensitivity was confirmed when sensing wrist/finger pulse and respiration [216].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [216] Li, 2018, Sensitive and Wearable Optical Microfiber Sensor for Human Health Monitoring, Adv. Mater. Technol. source
Not checked in the free run.
- Premisecitation
The Tempwatch smart bracelet allows continuous monitoring of body temperature via a built-in IR thermometer in addition to conventional PPG measurement.
“Other innovative thermometers are various SMART bracelets such as Tempwatch [160], which in addition to conventional PPG measurement also allows continuous monitoring of body temperature via a built-in IR thermometer.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [160] (2022, March 08). Youneedthisgadget Tempwatch, the Smartwatch with Infrared Thermometer. Available online: https://youneedthisgadget.com/tempwatch-the-smartwatch-with-infrared-thermometer/.
Not checked in the free run.
- Premisecitation
From the time evolution of temperature changes in the nasal region, basic vital parameters such as RR and RV can be determined.
“From the time evolution of temperature changes in the nasal region, it is also possible to determine basic vital parameters such as RR and RV.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [189] Blanik, 2014, Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior, J. Biomed. Opt. source
Not checked in the free run.
- Premisecitation
A stretchable and ultrathin optical sensor with a self-assembled wavy microfiber can monitor a pulse on the wrist with a high signal-to-noise ratio.
“Another approach uses a stretchable and ultrathin optical sensor with a self-assembled wavy microfiber (Figure 1h) [19]. It can monitor a pulse on the wrist with a high signal-to-noise ratio or, with the combination of an ECG, BP derived from pulse arrival time.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] Zhu, 2021, Self-Assembled Wavy Optical Microfiber for Stretchable Wearable Sensor, Adv. Opt. Mater.
Not checked in the free run.
- Premisecitation
A single temperature measurement can indicate whether a patient has fever or hypothermia.
“A single temperature measurement can tell us whether the patient has a fever or hypothermia [150,151,152,153,154].”
Quote in the paperNot a substantial claim0 of 5 sources checked- cites [150] Dell’isola, G.B., Cosentini, E., Canale, L., Ficco, G., and Dell’isola, M. (2021). Noncontact body temperature measurement: Uncertainty evaluation and screening decision rule to prevent the spread of COVID-19. Sensors, 21. source
Not checked in the free run.
- cites [151] Chin, J.W., Long Wong, K., Chan, T.T., Suhartono, K., and So, R.H.Y. (2021, January 19–25). An infrared thermography model enabling remote body temperature screening up to 10 meters. Proceedings of the 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW), Nashville, TN, USA. source
Not checked in the free run.
- cites [152] Švantner, M., Lang, V., Kohlschutter, T., Skála, J., Honner, M., Muzika, L., and Kosová, E. (2021). Study on Human Temperature Measurement by Infrared Thermography. Eng. Proc., 8. source
Not checked in the free run.
- cites [153] Khaksari, 2021, Review of the efficacy of infrared thermography for screening infectious diseases with applications to COVID-19, J. Med. Imaging source
Not checked in the free run.
- cites [154] Ng, 2005, Is thermal scanner losing its bite in mass screening of fever due to SARS?, Med. Phys. source
Not checked in the free run.
- Premisecitation
A non-core fiber with optimal length and a ring cavity filter can construct a fiber laser that sensitively detects RR and HR signals from shifts of lasing wavelength.
“Another approach uses a non-core fiber with optimal length as a sensing head, as well as a filter in a ring cavity to construct a type of fiber laser to sensitively detect RR and HR signals from the shifts of lasing wavelength [210].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [210] Li, 2019, Optical active fiber sensing technique based on the lasing wavelength demodulation for monitoring the human respiration and pulse, Sens. Actuators A Phys. source
Not checked in the free run.
- Premisecitation
Continuous measurement of core body temperature can determine the patient's circadian cycle.
“From continuous measurements of core body temperature, we can determine the circadian cycle of the patient.”
Quote in the paperNot a substantial claim0 of 5 sources checked- cites [134] Ogoina, 2011, Fever, fever patterns and diseases called “fever”—A review, J. Infect. Public Health source
Not checked in the free run.
- cites [135] Costa, 2018, Daily rhythm of skin temperature of women evaluated by infrared thermal imaging, J. Therm. Biol. source
Not checked in the free run.
- cites [136] Baschieri, 2021, Circadian and state-dependent core body temperature in people with spinal cord injury, Spinal Cord source
Not checked in the free run.
- cites [139] Edwards, 2009, Zeitgeber-effects of exercise on human circadian rhythms: What are alternative approaches to investigating the existence of a phase-response curve to exercise?, Biol. Rhythm Res. source
Not checked in the free run.
- cites [140] Chen, 2019, Thermometry and interpretation of body temperature, Biomed. Eng. Lett. source
Not checked in the free run.
- Premisecitation
Exposure of the human body to sunlight or artificial lighting can be evaluated by monitoring changes in hormone production, circadian stimuli, or circadian levels.
“We can evaluate the exposure of the human body to sunlight or artificial lighting, where changes in hormone production, circadian stimuli, or circadian levels are monitored [190].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [190] Salamone, F., Masullo, M., and Sibilio, S. (2021). Wearable Devices for Environmental Monitoring in the Built Environment: A Systematic Review. Sensors, 21. source
Not checked in the free run.
- Premisecitation
Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm.
“Commercially available PIR thermometers work with wavelengths from 8 μm to 14 μm, thus the sensor must be adapted to the radiation wavelength of human body temperature [130,157].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [130] Yu, W.L., Wang, Z., and Jin, L. (2012, January 5–7). The experiment study on infrared radiation spectrum of human body. Proceedings of the Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics BHI 2012, Hong Kong, China. source
Not checked in the free run.
- cites [157] Hardy, 1934, the Radiation of Heat from the Human Body. Iv. the Emission, Reflection, and Transmission of Infra-Red Radiation By the Human Skin, J. Clin. Investig. source
Not checked in the free run.
- Premisecitation
An SFS-based smart cushion with a fiberglass mesh/SFS/PVC sandwich structure can achieve a maximum error of 1 bpm.
“Furthermore, it is a smart cushion based on the SFS (single-mode-few-mode-single-mode) structure [221], where the sensing unit is a sandwich structure consisting of a piece of fiberglass mesh, an SFS structure layer, and a PVC layer and can achieve a maximum error of 1 bpm.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [221] Han, S., Xu, W., You, S., Dong, B., Tan, F., Yu, C., Zhao, W., and Wang, Y. (2020, January 4–8). Investigation on Smart Cushion Based on SFS Structure and its Application in Physiological and Activity Monitoring. Proceedings of the 2020 Opto-Electronics and Communications Conference (OECC), Taipei, Taiwan. source
Not checked in the free run.
- Premisecitation
Hetero-core optical fiber woven together with wool fibers offers a simple and cost-effective system for monitoring HR and RR.
“Hetero-core optical fiber woven together with wool fibers [208] offers a simple and cost-effective system for monitoring HR and RR.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [208] Koyama, 2018, Smart textile using hetero-core optical fiber for heartbeat and respiration monitoring, IEEE Sens. J. source
Not checked in the free run.
- Premisecitation
Continuous measurement of core body temperature can determine the stage of an ongoing disease.
“Another use of continuous measurement of the patient’s core body temperature is to determine the stage of the ongoing disease [155,156].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [155] Daskalos, A.-C., Theodoropoulos, P., Spandonidis, C., and Vordos, N. (2022). Wearable Device for Observation of Physical Activity with the Purpose of Patient Monitoring Due to COVID-19. Signals, 3. source
Not checked in the free run.
- cites [156] Facente, 2021, Feasibility and effectiveness of daily temperature screening to detect COVID-19 in a prospective cohort at a large public university, BMC Public Health source
Not checked in the free run.
- Premisecitation
Asymmetric breast temperature on a thermogram may indicate potential breast cancer.
“From this thermal scan, the doctor may indicate potential breast cancer in case of asymmetric breast temperature [163,164,165,166,167,168].”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [163] Brioschi, 2015, Reference breast temperature: Proposal of an equation, Einstein source
Not checked in the free run.
- cites [164] Guevara, 2021, Deep convolutional neural networks for classifying breast cancer using infrared thermography, Quant. Infrared Thermogr. J.
Not checked in the free run.
- cites [165] Mukhmetov, 2021, Thermal modeling for breast tumor detection using thermography, Int. J. Therm. Sci. source
Not checked in the free run.
- cites [166] Min, 2017, Thermal infrared image analysis for breast cancer detection, KSII Trans. Internet Inf. Syst.
Not checked in the free run.
- cites [167] Magalhaes, C., Mendes, J., and Vardasca, R. (2021). Meta-analysis and systematic review of the application of machine learning classifiers in biomedical applications of infrared thermography. Appl. Sci., 11. source
Not checked in the free run.
- cites [168] Duran, 2010, Comparison of standard mammography with digital mammography and digital infrared thermal imaging for breast cancer screening, J. Turkish Ger. Gynecol. Assoc. source
Not checked in the free run.
- Premisecitation
The most flexible optical fiber variants can monitor the joints of the human body.
“The most flexible variants are also capable of monitoring the joints of the human body [201,202].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [201] Massaroni, C., Saccomandi, P., and Schena, E. (2015). Medical Smart Textiles Based on Fiber Optic Technology: An Overview. J. Funct. Biomater., 6. source
Not checked in the free run.
- cites [202] Trung, 2018, Freestanding, Fiber-Based, Wearable Temperature Sensor with Tunable Thermal Index for Healthcare Monitoring, Adv. Healthc. Mater. source
Not checked in the free run.
- Premisecitation
Fiber optic ratiometric sensors with a hybrid sol-gel pH sensing material on a flexible POF tip can measure in vivo pH in the physiological range with a resolution of 0.0013 pH units.
“The use of fiber optic sensors for in vivo pH measurement is possible using ratiometric sensors based on a hybrid sol-gel pH sensing material deposited on a highly flexible POF tip capable of operating in the physiological pH range with a resolution of 0.0013 pH units.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [225] Wencel, 2018, Optical Sensor for Real-Time pH Monitoring in Human Tissue, Small source
Not checked in the free run.
- Premisecitation
Plasmonic gold nanoparticles assembled into stretchable elastomer-based optical fibers with a core/cladding step-index configuration can produce strain sensors that measure large strains with low detection limit, fast responsivity, and high reproducibility.
“One experiment is assembling plasmonic gold nanoparticles (GNPs) into stretchable elastomer-based optical fibers with a core/cladding structure with a step-index configuration. This configuration can obtain strong localized surface plasmon resonance effects and can produce strain sensors that can measure large strains with a low detection limit, fast responsivity, and high reproducibility [230].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [230] Guo, 2019, Stretchable and Highly Sensitive Optical Strain Sensors for Human-Activity Monitoring and Healthcare, ACS Appl. Mater. Interfaces source
Not checked in the free run.
- Premisecitation
Incorporating MNFs into PDMS thin layers can produce skin-like optical sensors with ultrahigh sensitivity, low detection limit, and fast response for pressure sensing.
“By incorporating MNFs into polydimethylsiloxane (PDMS) thin layers, it is possible to produce skin-like optical sensors with ultrahigh sensitivity, low detection limit, and fast response for pressure sensing [212].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [212] Zhang, 2020, Ultrasensitive skin-like wearable optical sensors based on glass micro/nanofibers, Opto-Electron. Adv. source
Not checked in the free run.
- Premisecitation
A 400 μm multimode optical fiber without coating gave a very good combination of sensitivity and SNR.
“Benneth et al. [209] experimented with 400 µm multimode optical fiber (MOF) without coating and obtained a very good combination of sensitivity and SNR.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [209] Bennett, 2020, Monitoring of Vital Bio-Signs by Multimode Speckle Based Optical Fiber Sensor, Clin. Transl. Biophoton. source
Not checked in the free run.
- Premisecitation
A chest belt with a single mode-multimode-single mode (SMS) fiber structure, using six different SMS fiber sensors tested on six subjects with short-time Fourier transform, achieved a Pearson correlation coefficient of p = 0.88.
“The fourth is the chest belt with a single mode-multimode-single mode (SMS) fiber structure, where six different SMS fiber sensors were tested on six subjects using a short-time Fourier transform and achieved a Pearson Correlation Coefficient with p = 0.88 [229].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [229] Pang, 2021, Wearable Optical Fiber Sensor Based on a Bend Singlemode-Multimode-Singlemode Fiber Structure for Respiration Monitoring, IEEE Sens. J. source
Not checked in the free run.
- Premisecitation
Twin-core fiber-based sensors under a mattress have a sensitivity of 18 nm/m−1 for monitoring HR and RR.
“Other articles are focused on applications in smart beds, specifically in thin mats [235,236] using twin-core fiber-based sensors fabricated by sandwiching single-mode fiber attached under a mattress with a sensitivity of 18 nm/m−1 for monitoring of HR and RR.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [235] Chen, 2018, Pharmacology & Therapeutics Synaptic dysfunction in Alzheimer’s disease: Mechanisms and therapeutic strategies, Pharmacol. Ther.
Not checked in the free run.
- cites [236] Tan, 2019, Non-invasive human vital signs monitoring based on twin-core optical fiber sensors, Biomed. Opt. Express source
Not checked in the free run.
- Premisecitation
An FBG sensor embedded in a soft polymer matrix for control of breathing and HR in archers offers a low mean absolute percentage error for RR and HR estimation (≤1.97% and ≤5.74%).
“They offer a low mean absolute percentage error for RR and HR estimation (≤1.97% and ≤5.74%).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [258] Lo Presti, D., Romano, C., Massaroni, C., D’Abbraccio, J., Massari, L., Caponero, M.A., Oddo, C.M., Formica, D., and Schena, E. (2019). Cardio-respiratory monitoring in archery using a smart textile based on flexible fiber bragg grating sensors. Sensors, 19. source
Not checked in the free run.
- Premisecitation
A fiber sandwich structure with a three × three coupler-based differentiate and cross-multiplying method achieves good reproducibility and accuracy with maximum errors of 2 bpm and 1 rpm in monitoring HR, HR amplitude, RR, and respiration amplitude.
“They applied a three × three coupler-based differentiate and cross-multiplying method [237] to achieve good reproducibility and accuracy with max. errors 2 bpm and 1 rpm in monitoring HR, HR amplitude, RR, and respiration amplitude.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [237] Wang, 2020, Noninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress, IEEE Sens. J. source
Not checked in the free run.
- Premisenone given
Meta-surfaces based on the plasmonic mechanism have high optical losses due to absorption in the metal, significantly limiting real-world applications.
“Meta-surfaces based on the plasmonic mechanism have high optical losses due to absorption in the metal, significantly limiting real-world applications.”
Quote in the paperSubstantial claim - Premisecitation
Commercial T-shirts equipped with a single fiber optic housing two FBGs glued on the textile with silicone rubber can monitor RR and HR waves.
“Furthermore, the commercial T-shirts equipped with a single fiber optic housing two FBGs for RR and HR waves’ monitoring, where the FBGs were glued on the textile with silicone rubber were reported [249,250,251].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [249] Massaroni, 2019, Wearable System Based on Flexible FBG for Respiratory and Cardiac Monitoring, IEEE Sens. J. source
Not checked in the free run.
- cites [250] Ciocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M.A., Polimadei, A., Formica, D., and Schena, E. (2015). Smart textile based on fiber bragg grating sensors for respiratory monitoring: Design and preliminary trials. Biosensors, 5. source
Not checked in the free run.
- cites [251] Massaroni, 2021, Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review, IEEE Sens. J. source
Not checked in the free run.
- Premisecitation
The challenge in colorimetric, fluorescence and luminescence sensors is the preparation of chemical detergents that indicate the presence of analytes by changing their optical properties.
“However, the challenge is the preparation of chemical detergents that indicate the presence of the analytes by changing their optical properties [74,277,278].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [74] Khan, 2019, Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring, IEEE Access source
Not checked in the free run.
- cites [277] Cheng, 2021, Recent Progress in Intelligent Wearable Sensors for Health Monitoring and Wound Healing Based on Biofluids, Front. Bioeng. Biotechnol. source
Not checked in the free run.
- cites [278] Purohit, 2020, Smartphone-assisted personalized diagnostic devices and wearable sensors, Curr. Opin. Biomed. Eng. source
Not checked in the free run.
- Premisecitation
Other colors can be achieved by Si meta-surfaces with various geometries and different lattice sizes of different geometric shapes.
“Other colors can be achieved by Si meta-surfaces with various geometries and different lattice sizes of different geometric shapes [285,286].”
Quote in the paperNot a substantial claim0 of 2 sources checked - Premisecitation
Implanting FBG sensors into fabric by combining large and small pipes reaches a temperature sensitivity of 150 pm/°C, almost 15 times higher than in bare FBG.
“Thus, they reach a temperature sensitivity of 150 pm/°C, which is almost 15 times higher than in bare FBG.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [247] Li, 2012, Wearable sensors in intelligent clothing for measuring human body temperature based on optical fiber Bragg grating, Opt. Express source
Not checked in the free run.
- Premisecitation
Plasmonic meta-surfaces can be prepared by color printing using laser post-writing with sub-diffraction-limit resolution.
“Plasmonic meta-surfaces can be prepared by color printing using laser post-writing with sub-diffraction-limit resolution.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [283] Asger, 2016, Plasmonic colour laser printing, Nat. Nanotechnol. source
Not checked in the free run.
- Premisecitation
A novel nanophotonic platform based on dielectric nanostructures overcomes the limitations of plasmonic meta-surfaces.
“Via the realization of a novel nanophotonic platform based on dielectric nanostructures to form efficient nanoantennae with ultra-low light-into heat conversion, is demonstrated an approach that overcomes these limitations.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [289] Caldarola, 2015, Non-plasmonic nanoantennas for surface enhanced spectroscopies with ultra-low heat conversion, Nat. Commun. source
Not checked in the free run.
- cites [290] Dong, 2021, Silicon Nanoantenna Mix Arrays for a Trifecta of Quantum Emitter Enhancements, Nano Lett. source
Not checked in the free run.
- Premisecitation
A long-term grating coated with molecularly imprinted fentanyl-sensitive polymer nanoparticles demonstrated in vitro drug level monitoring with a detection limit of 50 ng/mL.
“In vitro, drug level monitoring has also been demonstrated using a long-term grating coated with molecularly imprinted fentanyl-sensitive polymer nanoparticles (detection limit 50 ng/mL) [265].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [265] Morgan, S.P., Korposh, S., Liu, L., Hernandez, F.U., Correia, R., Norris, A., Sinha, R., Hayes-Gill, B.R., Piletsky, S.A., and Canfarotta, F. (2019, January 23–27). Optical fiber sensors for monitoring in critical care. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany. source
Not checked in the free run.
- Premisecitation
Single-mode in-fiber MZI can be introduced into a shirt to detect HR, respiration, and pulse wave velocity.
“From the application in smart clothing, single-mode in-fibers MZI can be introduced to detect HR, respiration, and pulse wave velocity in the shirt [233].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [233] Cartwright, A.N., Nicolau, D.V., and Fixler, D. (2017). Blood Pulse Wave Velocity and Pressure Sensing via Fiber Based and Free Space Based Optical Sensors, SPIE.
Not checked in the free run.
- Premisecitation
Microfluidics technology has become prominent in wearable intelligent sensor platforms for reducing samples and solvents.
“For reducing samples and solvents, microfluidics technology has become prominent in wearable intelligent sensor platforms [279,280,281].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [279] Wang, J., and Dong, J. (2020). Optical waveguides and integrated optical devices for medical diagnosis, health monitoring and light therapies. Sensors, 20. source
Not checked in the free run.
- cites [280] Roda, 2016, Smartphone-based biosensors: A critical review and perspectives, TrAC Trends Anal. Chem. source
Not checked in the free run.
- cites [281] Yan, 2021, Flexible Biosensors Based on Colorimetry, Fluorescence, and Electrochemistry for Point-of-Care Testing, Front. Bioeng. Biotechnol. source
Not checked in the free run.
- Premisecitation
Combining 12 fiber Bragg grating sensors into one smart textile performed detailed thoracic-abdominal motion pattern analysis with respiratory period error of 0.2 rpm and tidal volume error of 0.09 L.
“Sometimes researchers combined even 12 fiber Bragg grating sensors into one smart textile [257] to perform a detailed thoracic-abdominal motion pattern analysis and achieved good accuracy of the respiratory period (error 0.2 rpm) and tidal volume (error 0.09 L).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [257] Massaroni, 2018, Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation, J. Biophotonics source
Not checked in the free run.
- Premisecitation
Graphene oxide deposited onto a tilted fiber grating can monitor relative humidity and respiration with an ultrafast response within ∼42 ms and a sensitivity of 18.5 pm/%RH and 0.027 dB/%RH in the range of 30∼80% RH.
“Relative humidity (RH) and so respiration can also be monitored by depositing graphene oxide onto tilted fiber grating [274]. Thus, it offers an ultrafast response within ∼42 ms and a sensitivity of 18.5 pm/%RH and 0.027 dB/%RH in the range of 30∼80% RH by monitoring the wavelength and intensity of the specific cladding mode resonance.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [274] Jiang, 2019, Graphene oxide-deposited tilted fiber grating for ultrafast humidity sensing and human breath monitoring, Sens. Actuators B Chem. source
Not checked in the free run.
- Premisecitation
A Si nanoantenna array with two quasi-bound-states-in-the-continuum modes can achieve an ideal Schrödinger's red pixel.
“The meta-surface represented by Si nanoantenna array with two quasi–bound-states-in-the-continuum (q-BIC) modes can achieve an ideal Schrödinger’s red pixel [284].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [284] Dong, 2022, Schrödinger’ s red pixel by quasi-bound-states- in-the-continuum, Sci. Adv.
Not checked in the free run.
- Premisecitation
Luminescence-based optical devices are particularly attractive due to their good sensitivity and very high selectivity.
“Luminescence-based optical devices are particularly attractive due to their good sensitivity and very high selectivity [279].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [279] Wang, J., and Dong, J. (2020). Optical waveguides and integrated optical devices for medical diagnosis, health monitoring and light therapies. Sensors, 20. source
Not checked in the free run.
- Premisecitation
At present, there are already several wearable optical devices using the fluorescence method for health assessment or detection of biomarker concentration.
“At present, there are already several wearable optical devices using the fluorescence method for health assessment or detection of biomarker concentration [279].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [279] Wang, J., and Dong, J. (2020). Optical waveguides and integrated optical devices for medical diagnosis, health monitoring and light therapies. Sensors, 20. source
Not checked in the free run.
- Premisecitation
Yang et al. introduced a bandage-like wearable detector of nucleic acids with a detection limit of 10 copies/μL.
“Yang et al. [311] introduces a novel bandage-like wearable detector of nucleic acids. The sensor uses flexible microfluidic recombinase polymerase amplification and offers excellent sensitivity and selectivity with a detection limit of 10 copies/μL.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [311] Yang, 2019, Bandage-like wearable flexible microfluidic recombinase polymerase amplification sensor for the rapid visual detection of nucleic acids, Talanta source
Not checked in the free run.
- Premisecitation
Sekine et al. developed a wearable fluorometric sensor in the form of a soft, skin-interfaced microfluidic system to detect Na+, Cl−, and Zn2+ from eccrine sweat.
“Sekine et al. [23] developed a wearable fluorometric sensor in the form of a soft, skin-interfaced microfluidic system to detect Na+, Cl−, and zinc (Zn2+) from eccrine sweat(Figure 1l).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [23] Sekine, 2018, A fluorometric skin-interfaced microfluidic device and smartphone imaging module for: In situ quantitative analysis of sweat chemistry, Lab Chip source
Not checked in the free run.
- Premisecitation
Ryu et al. demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications that can detect the cardiac markers myoglobin and CK-MB from human plasma.
“Interesting and useful is also the research by Ryu et al. [36] where they demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications, consisting of 501 nm commercially available InGaN LED, an organic or silicon photodiode, absorptive dye-coated color filters, polarizers, and an injected polystyrene microfluidic chip.”
- Also stated in: § 5.2. Fluorescence · plain
“The system can detect the cardiac markers myoglobin and CK-MB from the human plasma.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [36] Ryu, 2011, Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip, Lab Chip source
Not checked in the free run.
- Also stated in: § 5.2. Fluorescence · plain
- Premisecitation
The stability of sensors, especially electrochemical ones, can be a problem, where passivation and biological contamination of the electrode can lead to an incorrect response.
“The stability of sensors, especially electrochemical ones, can be a problem, where passivation and biological contamination of the electrode can lead to an incorrect response [203].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [203] Hatamie, 2020, Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring, J. Electrochem. Soc. source
Not checked in the free run.
- Premisecitation
For accurate sensing and self-calibration in different lighting conditions, wearable colorimetric devices often have integrated reference graphic markers.
“For accurate sensing and self-calibration in different lighting conditions, wearable colorimetric devices often have integrated reference graphic markers [279].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [279] Wang, J., and Dong, J. (2020). Optical waveguides and integrated optical devices for medical diagnosis, health monitoring and light therapies. Sensors, 20. source
Not checked in the free run.
- Premisecitation
Guo et al. presented a stretchable and multifunctional optical sensor with simultaneous readout of body temperature and strain for wearable physiological monitoring of the human body.
“Guo et al. [319] presented a stretchable and multifunctional optical sensor (SMOS) with simultaneous readout of BT and strain for wearable physiological monitoring of the human body.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [319] Guo, 2019, Stretchable and upconversion-luminescent polymeric optical sensor for wearable multifunctional sensing, Opt. Lett. source
Not checked in the free run.
- Premisecitation
After pairing with a smartphone imaging module, the Sekine et al. system can monitor sweat biomarkers with an accuracy comparable to conventional laboratory equipment.
“After pairing with the smartphone imaging module, we can monitor sweat biomarkers with an accuracy comparable to conventional laboratory equipment.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [23] Sekine, 2018, A fluorometric skin-interfaced microfluidic device and smartphone imaging module for: In situ quantitative analysis of sweat chemistry, Lab Chip source
Not checked in the free run.
- Premisecitation
Moradi et al. designed a fluorescence-based pH sensor with microfluidic mixing and fiber optic detection that can detect pH in a wide range from 2.5 to 9.0.
“Further research is a fluorescence-based pH sensor with microfluidic mixing and fiber optic detection for a wide range of pH measurements designed by Moradi et al. [313].”
- Also stated in: § 5.2. Fluorescence · plain
“The excitation and emission lights are transmitted by multi-mode optical fiber, so they can simply and inexpensively detect pH in a wide range from 2.5 to 9.0.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [313] Moradi, 2019, A fluorescence-based pH sensor with microfluidic mixing and fiber optic detection for wide range pH measurements, Sens. Actuators A Phys. source
Not checked in the free run.
- Also stated in: § 5.2. Fluorescence · plain
- Premisecitation
Yokota et al.'s ultrathin skin-like system can unobtrusively measure oxygen concentration on the finger.
“After the light passes through the body, the OPD can detect red and green light emitted by the polymer LEDs and the device can unobtrusively measure the oxygen concentration on the finger.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [13] Yokota, 2016, Ultraflexible organic photonic skin, Sci. Adv. source
Not checked in the free run.
- Premisecitation
An ultra-thin flexible oximeter array with silicon-integrated circuits can monitor a pulsatile arterial blood signal.
“The first presented device (Figure 1c) is an ultra-thin flexible oximeter array with silicon-integrated circuits that can monitor a pulsatile arterial blood signal [14].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [14] Khan, 2018, A flexible organic reflectance oximeter array, Proc. Natl. Acad. Sci. USA source
Not checked in the free run.
- May combine two claims. 67
- Classified as probably not a substantial claim. 40
May combine two claims.
PremisecitationOptical sensors offer excellent metrological properties such as low zero and low sensitivity drift, good accuracy, sensitivity, and large usable bandwidth.
“They propose excellent metrological properties such as low zero and low sensitivity drift, good accuracy, sensitivity, and large usable bandwidth [24].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [24] Hayward, J. (2022, January 26). Wearable Sensors 2021–2031. Available online: http://www.idtechex.com/en/research-report/wearable-sensors-2021-2031/780.
Not checked in the free run.
May combine two claims.
PremisecitationOptical sensors are immune to electromagnetic interference and electrically safe.
“They are immune to electromagnetic interference, electrically safe, can achieve outstanding miniaturization, and they are capable of capturing nanoscale volumes, allowing the non-invasive examination of biological matter with relatively large penetration depths.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [25] Rehg, J.M., Murphy, S.A., and Kumar, S. (2017). Wearable Optical Sensors. Mobile Health, Springer International Publishing. source
Not checked in the free run.
May combine two claims.
PremisecitationOptical sensors can achieve outstanding miniaturization and capture nanoscale volumes, allowing non-invasive examination of biological matter with relatively large penetration depths.
“They are immune to electromagnetic interference, electrically safe, can achieve outstanding miniaturization, and they are capable of capturing nanoscale volumes, allowing the non-invasive examination of biological matter with relatively large penetration depths.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [25] Rehg, J.M., Murphy, S.A., and Kumar, S. (2017). Wearable Optical Sensors. Mobile Health, Springer International Publishing. source
Not checked in the free run.
May combine two claims.
PremisecitationOptical sensing elements are often inexpensive, water- and corrosion-resistant.
“Sensing elements, whether in the form of optical fibers or optically transparent encapsulated photoplethysmographic and biochemical sensors, are often inexpensive, water- and corrosion-resistant [25].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [25] Rehg, J.M., Murphy, S.A., and Kumar, S. (2017). Wearable Optical Sensors. Mobile Health, Springer International Publishing. source
Not checked in the free run.
May combine two claims.
PremisecitationThe PPG signal recorded in a real environment often contains movement artifacts and is affected by changing pressure of sensor on skin.
“The PPG signal, when recorded in a real environment, often contains movement artifacts and is also affected by the changing pressure of the sensor on the skin [80].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [80] Horton, 2017, Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise, Med. Sci. Sport. Exerc. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenA progressive method for RR measurement is algorithms extraction from captured PPG signal.
“Today, a very progressive method is the algorithms’ extraction from the captured photoplethysmography signal.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
InterpretationreasoningChanges in blood vessel walls due to HR can be easily and reliably detected by optical sensors, mostly PPG or optical fiber.
“These changes can be easily and reliably detected by optical sensors, mostly PPG or optical fiber.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Interpretationnone givenPPG technology is very successful but not fully reliable; limitations are in measurement standardization, setting regularizing ranges of data to correlate with patients, and evaluation of different treatment actions.
“PPG technology is very successful but still not ideal. There are still challenges and improvements to be made. PPG is not fully reliable, the limitations are in the measurement’s standardization, the setting up of regularizing ranges of data to correlate with patients, and the evaluation of different treatment actions.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationLow HRV indicates body is working hard, tired, dehydrated, stressed, or sick.
“Low HRV indicates that the body is working hard, it is tired, dehydrated, stressed, or sick [42,43].”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationHR measuring using PPG is well characterized and works seamlessly, but data processing for healthcare applications is large and requires considerable computing power and continuous energy supply.
“HR measuring using PPG is well characterized and works seamlessly; however, we must take into account that the amount of data processing for healthcare applications is large and requires considerable computing power and continuous energy supply [11].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [11] Yetisen, 2018, Wearables in Medicine, Adv. Mater. source
Not checked in the free run.
May combine two claims.
Premisenone givenReflective PPG has lower signal quality but is more suitable for nonstop wearing.
“This configuration has a lower signal quality, but it is more suitable for nonstop wearing.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenSpO2 provides information on lung efficiency and is an important indicator of overall human health.
“The SpO2 provides information on lung efficiency and is an important indicator of overall human health.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenLight in visible to NIR region can only reach human tissues to depth of a few millimeters, and penetration is limited by absorption by blood, melanin, fat, water, and light scattering.
“Light in the spectrum from the visible to the near-infrared (NIR) region can only reach human tissues to a depth of a few millimeters, and its penetration is limited due to the absorption of light by blood, melanin, fat, water, and light scattering.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenPPG is one of the most widely used optical imaging methods in healthcare, used to monitor blood flow in real-time.
“In healthcare, one of the most widely used optical imaging methods is photoplethysmography (PPG) (Table 1), which is used to monitor blood flow in real-time.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenThe accuracy of home glucometers varies ±15%.
“The accuracy of home glucometers also varies ±15%.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe non-pulsating component of PPG is a function of basal blood volume, respiration, sympathetic nervous system activity, and thermoregulation.
“The pulsating component is related to changes in arterial blood volume and is synchronous with the heartbeat, while the non-pulsating component is a function of basal blood volume, respiration, sympathetic nervous system activity, and thermoregulation [54].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [54] Utami, N., Setiawan, A.W., Zakaria, H., Mengko, T.R., and Mengko, R. (2013, January 7–8). Extracting blood flow parameters from Photoplethysmograph signals: A review. Proceedings of the 2013 3rd International Conference on Instrumentation, Communications, Information Technology and Biomedical Engineering (ICICI-BME), Bandung, Indonesia. source
Not checked in the free run.
May combine two claims.
PremisecitationRed light and NIR penetrate deeper into human body and provide a wider range of information about physiological signal.
“On the contrary, red light and NIR penetrate deeper into the human body and thus provide a wider range of information about the physiological signal [55,56].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [55] Elgendi, 2019, The use of photoplethysmography for assessing hypertension, NPJ Digit. Med. source
Not checked in the free run.
- cites [56] Marzorati, 2020, Chest Wearable Apparatus for Cuffless Continuous Blood Pressure Measurements Based on PPG and PCG Signals, IEEE Access source
Not checked in the free run.
May combine two claims.
PremisecitationThe pulsating component of PPG is related to changes in arterial blood volume and is synchronous with heartbeat.
“The pulsating component is related to changes in arterial blood volume and is synchronous with the heartbeat, while the non-pulsating component is a function of basal blood volume, respiration, sympathetic nervous system activity, and thermoregulation [54].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [54] Utami, N., Setiawan, A.W., Zakaria, H., Mengko, T.R., and Mengko, R. (2013, January 7–8). Extracting blood flow parameters from Photoplethysmograph signals: A review. Proceedings of the 2013 3rd International Conference on Instrumentation, Communications, Information Technology and Biomedical Engineering (ICICI-BME), Bandung, Indonesia. source
Not checked in the free run.
May combine two claims.
Premisenone givenTransmission PPG measurements are more stable, repetitive, and less sensitive to position changes.
“Such measurements are more stable, repetitive, and less sensitive to position changes.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenMonitoring processes in human body allows easier detection of vital signs such as HR, RR, blood pressure, allowing early rapid diagnosis and prevention.
“Monitoring the processes in the human body allows easier detection of vital signs such as heart rate (HR), respiratory rate (RR), blood pressure, etc., allowing early rapid diagnosis and prevention to be performed, and generally helping people to monitor their physiological parameters and inform the doctor in case of change.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationPPG is used to determine physiological parameters such as oxygen saturation, blood pressure, cardiac output, respiration, and to evaluate autonomic function, depth of anesthesia, and detection of peripheral vascular disease.
“It is used to determine the physiological parameters such as oxygen saturation, blood pressure, cardiac output, respiration but also to evaluate autonomic function, depth of anesthesia, as well as detection of peripheral vascular disease [52].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [52] Shelley, 2007, Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate, Anesth. Analgesia source
Not checked in the free run.
May combine two claims.
Premisenone givenOptical sensors offer a non-invasive method of continuous glucose measurement, unlike current glucometers requiring blood collection from a finger.
“In this case, the sensors offer a non-invasive method of continuous measurement, unlike current glucometers, which require blood collection from a finger.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationThe PPG signal is a mixture of blood flow in veins and arteries and consists of a pulsating and non-pulsating component of blood volume.
“The PPG signal is a mixture of blood flow in the veins and arteries and generally consists of a pulsating and non-pulsating component of the blood volume [53].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [53] Lee, 2011, Relations between ac-dc components and optical path length in photoplethysmography, J. Biomed. Opt. source
Not checked in the free run.
May combine two claims.
PremisecitationA photonic crystal that responds to glucose levels has been described; the sensor bends light and the diffracted band shifts as glucose concentration changes.
“The development of optic sensors today focuses on the rapid, continuous and simple determination of glucose in surrounding body fluids, for example, the use of a photonic crystal that responds to glucose levels has been described, the sensor bends light, and the diffracted band shifts as the glucose concentration changes [47].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [47] Alexeev, 2004, Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid, Clin. Chem. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationcitationDevices using NFC communication represent a promising version of HR monitors.
“Devices using NFC communication represent a very promising version of HR monitors [85].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [85] Kang, M.H., Lee, G.J., and Yun, J.H. (2021). NFC-Based Wearable Optoelectronics Working with Smartphone Application for Untact Healthcare. Sensors, 21. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningTransmission PPG configuration uses LEDs and photodiode facing each other, light passes through tissue, measuring non-absorbed light.
“If the light-emitting diodes (LEDs) and the photodiode (PD) are facing each other and the light passes through the tissue, where we measure the non-absorbed light, we speak of the transmission principle.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisereasoningEstimation of SpO2 is based on different spectral characteristics of hemoglobin and deoxyhemoglobin, thus two LEDs are used.
“These measurements are similar to those using LEDs and PDs, but the estimation of SpO2 level is based on the different spectral characteristics of hemoglobin and deoxyhemoglobin, thus two LEDs are used.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenOptical sensors in medicine can be used to increase intelligence of medical equipment, implants, and to monitor human physiology remotely even without direct contact with patient.
“They can be used to increase the intelligence of medical equipment, implants, and to monitor human physiology remotely even without direct contact with the patient.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenIn many cases, optical sensors do not have to be in direct contact with the human body or do not require high quality of contact.
“In many cases, the optical sensors do not even have to be in direct contact with the human body or do not require a high quality of contact.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationOrganic semiconductor devices have attractive properties including simple production on flexible substrates, miniaturization, simultaneous generation and detection of optical signal, and tunable light emission over a wide range.
“Organic semiconductor devices have many attractive properties. These include simple production on flexible substrates, the possibility of miniaturization, the simultaneous ability to generate and detect an optical signal, and tunable light emission in a wide range of values [33,34,35].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [33] Sessolo, 2013, Easy-to-fabricate conducting polymer microelectrode arrays, Adv. Mater. source
Not checked in the free run.
- cites [34] Forrest, 2004, The path to ubiquitous and low-cost organic electronic appliances on plastic, Nature source
Not checked in the free run.
- cites [35] Li, 2012, Polymer solar cells, Nat. Photonics source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationHigh HRV indicates nervous system is balanced and body can adapt to environment and function well.
“When the HRV is high, the nervous system is balanced, and the body can adapt to the environment and function well.”
Quote in the paperNot a substantial claim0 of 2 sources checkedMay combine two claims.
PremisecitationPDs and LEDs must be optically isolated, and the whole optical system must be surrounded by optical separation techniques to reduce ambient light impact.
“PDs and the LEDs must be optically isolated [78], for example, using a raised mesa, and the whole optical system must be surrounded by optical separation techniques to reduce the impact of ambient light [79].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [78] Pateau, 2019, Photoplethysmographic determination of the respiratory rate in acutely ill patients: Validation of a new algorithm and implementation into a biomedical device, Ann. Intensive Care source
Not checked in the free run.
- cites [79] Li, 2019, The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review, JMIR mHealth uHealth source
Not checked in the free run.
May combine two claims.
PremisecitationTison's group used a PPG sensor and accelerometer of a commercial smartwatch to obtain HR data and steps; their device can detect atrial fibrillation with sensitivity 98% and specificity 90.2%.
“Thanks to the algorithm based on heuristic pretraining and deep neural network training, their device can detect the fibrillation with sensitivity of 98% and specificity of 90.2% [83].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [83] Tison, 2018, Passive detection of atrial fibrillation using a commercially available smartwatch, JAMA Cardiol. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationToday, about 15% of the market for wearable devices is based on optical sensors and this number is constantly growing.
“Today, about 15% of the market for wearable devices is based on optical sensors and this number is constantly growing [24].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [24] Hayward, J. (2022, January 26). Wearable Sensors 2021–2031. Available online: http://www.idtechex.com/en/research-report/wearable-sensors-2021-2031/780.
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationLiterature mentions an "optical window" for wavelengths of 600 to 1300 nm.
“In the literature is also mentioned an “optical window” for wavelengths of 600 to 1300 nm [57,58,59].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [57] Ash, 2017, Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods, Lasers Med. Sci. source
Not checked in the free run.
- cites [58] Anderson, 1981, The optics of human skin, J. Invest. Dermatol. source
Not checked in the free run.
- cites [59] Young, 1997, Chromophores in human skin, Phys. Med. Biol. source
Not checked in the free run.
May combine two claims.
PremisecitationBreathing manifests in PPG in three ways: pulse wave amplitudes affected by blood vessel flexibility, variation in pulse shape, and decrease in intrathoracic pressure leading to increased venous return during inspiration.
“Breathing manifests itself in PPG in three ways. Pulse wave amplitudes are affected by the blood vessel flexibility, the variation in pulse shape, and a decrease in intrathoracic pressure that leads to increased venous return during inspiration [96,97].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [96] Akbar, U., Akbari, A., Alinia, P., Amato, F., Amendola, S., Balaban, E., Beach, C., Bertschi, M., Braun, F., and Caldani, L. (2021). Wearable Sensors: Fundamentals, Implementation and Applications. Wearable Sensors, Elsevier.
Not checked in the free run.
- cites [97] Madhav, K.V., Ram, M.R., Krishna, E.H., Komalla, N.R., and Reddy, K.A. (2011, January 10–12). Estimation of respiration rate from ECG, BP and PPG signals using empirical mode decomposition. Proceedings of the 2011 IEEE International Instrumentation and Measurement Technology Conference, Hangzhou, China. source
Not checked in the free run.
May combine two claims.
PremisecitationA flexible battery-free PPG wireless NFC monitoring device incorporating SpO2, HR, and HRV can be mounted on a thumbnail or ear lobe.
“A very promising design is the flexible concept (Figure 1a) [12], which incorporates advanced optoelectronic functions for PPG wireless NFC monitoring applications, including SpO2, HR, and HRV.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [12] Kim, 2017, Miniaturized Battery-Free Wireless Systems for Wearable Pulse Oximetry, Adv. Funct. Mater. source
Not checked in the free run.
May combine two claims.
PremisecitationMyosin protein in muscle sarcomeres has liquid crystalline properties and is responsible for anisotropic behavior of muscles.
“The myosin protein in muscle sarcomeres has liquid crystalline properties and is responsible for the anisotropic behavior of muscles [39].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [39] Bansal, 2015, Wearable Organic Optoelectronic Sensors for Medicine, Adv. Mater. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationAdhikari et al. developed a multi-wavelength transmission mode PPG method to monitor drug delivery and examined concentrations of therapeutic gold nanoparticles, quinine, and amphotericin B in mice with absorption peaks in 350-1100 nm range.
“Adhikari et al. [125] developed a multi-wavelength transmission mode PPG method to monitor drug delivery. They examined the concentration of therapeutic gold nanoparticles, quinine, and amphotericin B in mice possessing absorption peaks in the 350–1100 nm range.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [125] Coté, G.L. (2014). Multi-Wavelength Pulse Plethysmography for Real-Time Drug Delivery Monitoring, SPIE.
Not checked in the free run.
May combine two claims.
PremisecitationRR and amplitude of respiration can be extracted from PPG.
“Therefore, we can extract the RR and amplitude of respiration [98,99,100].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [98] Karlen, 2013, Multiparameter Respiratory Rate Estimation from the Photoplethysmogram, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
- cites [99] Nemati, 2010, Data Fusion for Improved Respiration Rate Estimation, EURASIP J. Adv. Signal Process. source
Not checked in the free run.
- cites [100] Shokoueinejad, 2017, Sleep apnea: A review of diagnostic sensors, algorithms, and therapies, Physiol. Meas. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Premisenone givenA thermal camera captures multiple points while a PIR sensor senses only one.
“The only difference between a thermal camera and a PIR sensor is that a thermal camera captures multiple points while a PIR sensor senses only one.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe boundary between internal and peripheral body temperature is indeterminate and varies with ambient temperature.
“Internal body temperature is different from the body temperature of peripherals such as limbs, and the boundary between them is indeterminate and varies with ambient temperature [134].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [134] Ogoina, 2011, Fever, fever patterns and diseases called “fever”—A review, J. Infect. Public Health source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenToday, optical blood pressure monitoring is a complete tool that can be built into firmware or software, allowing continuous cuffless BP measurement for virtually any type of PPG sensor.
“Today, optical blood pressure monitoring is a complete tool that can be built directly into the firmware or subsequent software, allowing it to be possible to continuously measure blood pressure without using a cuff for virtually any type of PPG sensor.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe cheapest form of radiation sensor is a passive infrared (PIR) sensor used in handheld non-contact thermometers.
“The cheapest form is a passive infrared (PIR) sensor used in handheld non-contact thermometers [131].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [131] Fang, 2006, Path-dependent human identification using a pyroelectric infrared sensor and fresnel lens arrays, Opt. Express source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSome researchers identified that orange and green lights perform better for SpO2 because of resistance to motion artifacts.
“However, some researchers have identified that orange and green lights perform better because of their resistance to motion artifacts [88,89].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [88] Raghavachari, R., Liang, R., and Pfefer, T.J. (2018). An applicable approach for extracting human heart rate and oxygen saturation during physical movements using a multi-wavelength illumination optoelectronic sensor system. Proceedings of the Design and Quality for Biomedical Technologies XI, SPIE.
Not checked in the free run.
- cites [89] Alharbi, S., Hu, S., Mulvaney, D., Barrett, L., Yan, L., Blanos, P., Elsahar, Y., and Adema, S. (2018). Oxygen Saturation Measurements from Green and Orange Illuminations of Multi-Wavelength Optoelectronic Patch Sensors. Sensors, 19. source
Not checked in the free run.
May combine two claims.
PremisecitationPolat et al. designed a flexible NFC patch to record HR, SpO2, and respiration, with a photodiode based on graphene sensitized with semiconducting quantum dots.
“A similar flexible device was presented by Polat et al. [90], who designed a patch to record HR, SpO2, and respiration. Again, the communication is via NFC, but the photodiode in this case is based on graphene sensitized with semiconducting quantum dots.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [90] Polat, 2019, Flexible graphene photodetectors for wearable fitness monitoring, Sci. Adv. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationRadiation sensors are popularly used to detect body temperature in association with infectious diseases.
“Nowadays, radiation sensors are popularly used to detect body temperature in association with infectious diseases [129,130].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [129] Hussain, 2021, Proper use of noncontact infrared thermometry for temperature screening during COVID-19, Sci. Rep. source
Not checked in the free run.
- cites [130] Yu, W.L., Wang, Z., and Jin, L. (2012, January 5–7). The experiment study on infrared radiation spectrum of human body. Proceedings of the Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics BHI 2012, Hong Kong, China. source
Not checked in the free run.
May combine two claims.
PremisecitationThe achieved maximum correlation coefficient of blood glucose determination is 0.91 and 0.86, respectively, representing a standard prediction error of approximately 6.16 mg/dl.
“The achieved maximum correlation coefficient of blood glucose determination is 0.91 and 0.86, respectively, which represents a standard prediction error of approximately 6.16 mg/dl.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationCore body temperature is lower in the early morning and has its greatest increase in the afternoon, with up to a 1 °C difference.
“In the early morning, the temperature is lower with the greatest increase in the afternoon, which can be up to a 1 °C difference [135,136,137,138,139,140].”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [135] Costa, 2018, Daily rhythm of skin temperature of women evaluated by infrared thermal imaging, J. Therm. Biol. source
Not checked in the free run.
- cites [136] Baschieri, 2021, Circadian and state-dependent core body temperature in people with spinal cord injury, Spinal Cord source
Not checked in the free run.
- cites [137] Baker, 2007, Circadian rhythms, sleep, and the menstrual cycle, Sleep Med. source
Not checked in the free run.
- cites [138] Honma, 2013, [Circadian rhythms in body temperature and sleep], Nihon Rinsho.
Not checked in the free run.
- cites [139] Edwards, 2009, Zeitgeber-effects of exercise on human circadian rhythms: What are alternative approaches to investigating the existence of a phase-response curve to exercise?, Biol. Rhythm Res. source
Not checked in the free run.
- cites [140] Chen, 2019, Thermometry and interpretation of body temperature, Biomed. Eng. Lett. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThermal cameras have a spectral range of 7.5-14 μm.
“This spectral range is almost identical to thermal cameras, where it is in the range of 7.5–14 μm [146].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [146] Bernard, 2013, Infrared camera assessment of skin surface temperature—Effect of emissivity, Phys. Medica source
Not checked in the free run.
May combine two claims.
InterpretationcitationPPGI and IRTI allow long-term monitoring or monitoring of effects with special local characteristics.
“Hence, these methods allow long-term monitoring or monitoring of effects with special local characteristics [189].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [189] Blanik, 2014, Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior, J. Biomed. Opt. source
Not checked in the free run.
May combine two claims.
PremisecitationPPGI measurements can determine HR, HRV, RR, respiratory variability (RV), and vasomotion activity.
“From PPGI measurements, the algorithm can determine HR, HRV, RR, respiratory variability (RV), and vasomotion activity.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [189] Blanik, 2014, Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior, J. Biomed. Opt. source
Not checked in the free run.
May combine two claims.
PremisecitationPDMS HR and RR sensors with frequency-domain signal processing and filters achieve errors below 4 bpm and 2 rpm, applicable in ballistocardiography in different areas of the human body.
“Applications in smart textiles such as HR and RR PDMS sensors with a focus on signal processing and analysis in the frequency domain and the application of various filters in research offers errors below 4 bpm and 2 rpm (respiration per minute) with good accuracy applicable in ballistocardiography in different areas of the human body [214].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [214] Leal-Junior, A.G., Diaz, C.A.R., Avellar, L.M., Pontes, M.J., Marques, C., and Frizera, A. (2019). Polymer optical fiber sensors in healthcare applications: A comprehensive review. Sensors, 19. source
Not checked in the free run.
May combine two claims.
PremisecitationThermal cameras can be used for photoplethysmography imaging (PPGI) and infrared thermographic imaging (IRTI) for contactless measurement of a wide range of basic vital parameters.
“Thermal cameras can also be used for photoplethysmography imaging (PPGI) and infrared thermographic imaging (IRTI), where contactless measurement of a wide range of basic vital parameters is performed.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [189] Blanik, 2014, Hybrid optical imaging technology for long-term remote monitoring of skin perfusion and temperature behavior, J. Biomed. Opt. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationInfrared thermometers can be classified as wearable devices due to their compactness.
“Due to infrared thermometers’ compactness, these devices can be classified as wearable devices [158].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [158] Tamura, 2017, Body temperature, heat flow and evaporation, Seamless Healthc. Monit. Adv. Wearable Attach. Invis. Devices
Not checked in the free run.
May combine two claims.
PremisecitationA POF embedded in mattresses can measure respiration and HR to monitor sleep performance, tested on 10 subjects.
“First, a POF is embedded in mattresses to measure respiration and HR to monitor sleep performance, which was tested on 10 subjects [219].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [219] Han, 2021, Low-cost plastic optical fiber sensor embedded in mattress for sleep performance monitoring, Opt. Fiber Technol. source
Not checked in the free run.
May combine two claims.
PremisecitationOptical fibers can monitor human vital signs such as respiration, cardiac activity, blood pressure and flow, oxygen saturation, shear stress, mobility, gait, temperature, and electrolyte balance.
“Optical fibers can function as inconspicuous flexible systems monitoring human vital signs such as respiration, cardiac activity, blood pressure and flow, oxygen saturation, shear stress, mobility, gait, temperature, and electrolyte balance.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [201] Massaroni, C., Saccomandi, P., and Schena, E. (2015). Medical Smart Textiles Based on Fiber Optic Technology: An Overview. J. Funct. Biomater., 6. source
Not checked in the free run.
- cites [202] Trung, 2018, Freestanding, Fiber-Based, Wearable Temperature Sensor with Tunable Thermal Index for Healthcare Monitoring, Adv. Healthc. Mater. source
Not checked in the free run.
May combine two claims.
PremisecitationPOFs embroidered into a moisture-wicking fabric can detect early changes in skin perfusion, oxygen saturation, HR, blood flow, and pressure on tissue for pressure ulcer prevention.
“Research on the prevention of pressure ulcers in sensitive skin conditions that can detect early changes in skin perfusion, oxygen saturation, HR, blood flow, and pressure on the tissue, and subsequent therapeutic intervention in which POFs are embroidered into a moisture-wicking fabric appears to be very advanced [222].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [222] Quandt, 2017, Body-monitoring with photonic textiles: A reflective heartbeat sensor based on polymer optical fibres, J. R. Soc. Interface
Not checked in the free run.
May combine two claims.
PremisecitationThe POF mattress sensor has an absolute error less than 1 rpm and 2 bpm.
“Its absolute error was less than 1 rpm and 2 bpm.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [219] Han, 2021, Low-cost plastic optical fiber sensor embedded in mattress for sleep performance monitoring, Opt. Fiber Technol. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationNanoimprinted meta-surfaces consist of a 20 nm aluminum film buried in a thin-film polymer that is flexible, economical, and recyclable.
“Nanoimprinted meta-surfaces consist of a 20 nm aluminum film buried in a thin-film polymer that is flexible, economical, and recyclable [283].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [283] Asger, 2016, Plasmonic colour laser printing, Nat. Nanotechnol. source
Not checked in the free run.
May combine two claims.
PremisecitationIn wearable electronics, analyses of sweat, saliva, and tears are mainly performed, and pH, lactate, glucose, Na+, Cl−, Ca2+, Zn2+, and other chemical elements are detected.
“In the field of wearable electronics the analyses of sweat, saliva, and tears are mainly performed and in addition to recording their amount, the pH, lactate, glucose, Na+, Cl−, Ca2+, Zn2+, and other chemical elements are detected [276].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [276] Zhu, D., Liu, B., and Wei, G. (2021). Two-dimensional material-based colorimetric biosensors: A review. Biosensors, 11. source
Not checked in the free run.
May combine two claims.
PremisecitationFBGs encapsulated inside PDMS can work as a multichannel sensor for body temperature, RR, and HR estimation or for evaluation of cardiac functions from carotid HR waveform.
“FBGs encapsulated inside PDMS can work as a multichannel sensor for body temperature, RR, and HR estimation [253], or evaluation of the cardiac functions from carotid HR waveform [254].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [253] Fajkus, M., Nedoma, J., Martinek, R., Vasinek, V., Nazeran, H., and Siska, P. (2017). A non-invasive multichannel hybrid fiber-optic sensor system for vital sign monitoring. Sensors, 17. source
Not checked in the free run.
- cites [254] Padma, 2018, Carotid Arterial Pulse Waveform Measurements Using Fiber Bragg Grating Pulse Probe, IEEE J. Biomed. Health Inform. source
Not checked in the free run.
May combine two claims.
PremisecitationMeta-surfaces as structural color can achieve strong static or dynamic colorimetry and are tunable by external stimuli such as mechanical stress, temperature change, electrical voltage, and optical excitation.
“Meta-surfaces as a „structural color” can achieve strong static or dynamic colorimetry. These are tunable by external stimuli, such as mechanical stress, temperature change, electrical voltage, and optical excitation [288].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [288] Dong, 2021, Nanophotonic Structural Colors, ACS Photonics source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationA 3D skin temperature mapping method based on an improved neural network genetic algorithm-back propagation has an absolute error of 0.11 °C.
“The method for 3D skin temperature mapping based on an improved neural network genetic algorithm-back propagation with an absolute error of 0.11 °C is also interesting [248].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [248] Liu, 2019, An Optical Fiber-Based Data-Driven Method for Human Skin Temperature 3-D Mapping, IEEE J. Biomed. Health Inform. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenColorimetry is suitable for many photo-medical applications and biomarker detections including electrolytes, small molecules, and proteins.
“Colorimetry is suitable for many photo-medical applications and biomarker detections including electrolytes, small molecules, and proteins.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationAll wearable biochemical sensors have limitations such as frequent calibration, readout drift due to biofouling, and biweekly sensor replacement.
“All wearable biochemical sensors have some limitations, such as frequent calibration, readout drift due to biofouling, and biweekly sensor replacement [11].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [11] Yetisen, 2018, Wearables in Medicine, Adv. Mater. source
Not checked in the free run.
May combine two claims.
PremisecitationFBG technology has simple manufacturing, relatively strong signal reflection, resistance to optical signal intensity modulation, and excellent multiplexing and self-referencing capabilities allowing addressing of multiple sensors with a single optical cable.
“FBG technology is one of the most admired options due to its simple manufacturing, relatively strong signal reflection, and resistance to optical signal intensity modulation, which is possible due to their spectral coding, as well as excellent multiplexing and self-referencing capabilities allowing addressing of multiple sensors with a single optical cable [243].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [243] Majumder, 2008, Fibre Bragg gratings in structural health monitoring—Present status and applications, Sens. Actuators A Phys. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationFabry-Perot sensors based on ethyl alpha cyanoacrylate fibers are used to monitor HR.
“Applications are also known where Fabry–Perot sensors based on ethyl alpha cyanoacrylate fibers are used to monitor HR [239].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [239] Li, 2021, Heart-Rate Monitoring with an Ethyl Alpha-Cyanoacrylate Based Fiber Fabry-Perot Sensor, IEEE J. Sel. Top. Quantum Electron.
Not checked in the free run.
May combine two claims.
PremisecitationA miniature MRI-compatible multi-sensor offers a temperature accuracy of ±0.22 °C, a pressure resolution of 1 mmHg, and a localization resolution of 3 mm.
“The miniature sensor offers a temperature accuracy of ±0.22 °C, a pressure resolution of 1 mmHg, and a localization resolution of 3 mm.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [275] Zolfaghari, 2021, MRI Compatible Fiber Optic Multi Sensor Platform for Real Time Vital Monitoring, J. Light. Technol. source
Not checked in the free run.
May combine two claims.
PremisecitationFBG sensors are small, portable, yarn compatible, easy to weave into fabrics, and have become the most promising material for sensing elements in intelligent clothing.
“FBG sensors are small, portable, yarn compatible, and easy to weave into fabrics, and have become the most promising material for sensing elements in creating intelligent clothing [242,244,245].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [242] Sahota, 2020, Fiber Bragg grating sensors for monitoring of physical parameters: A comprehensive review, Opt. Eng. source
Not checked in the free run.
- cites [244] Li, 2016, Review of the Strain Modulation Methods Used in Fiber Bragg Grating Sensors, J. Sens. source
Not checked in the free run.
- cites [245] Campanella, C.E., Cuccovillo, A., Campanella, C., Yurt, A., and Passaro, V.M.N. (2018). Fibre Bragg Grating based strain sensors: Review of technology and applications. Sensors, 18. source
Not checked in the free run.
May combine two claims.
PremisecitationA dimer-like silicon-based single nanoantenna produces both high surface enhanced fluorescence and surface enhanced Raman scattering while generating a negligible temperature increase in its hot spots and surrounding environment.
“Dimer-like silicon-based single nanoantenna produces both high surface enhanced fluorescence and surface enhanced Raman scattering, while generating a negligible temperature increase in their hot spots and surrounding environment at the same time [289,290].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [289] Caldarola, 2015, Non-plasmonic nanoantennas for surface enhanced spectroscopies with ultra-low heat conversion, Nat. Commun. source
Not checked in the free run.
- cites [290] Dong, 2021, Silicon Nanoantenna Mix Arrays for a Trifecta of Quantum Emitter Enhancements, Nano Lett. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Interpretationnone givenCompared to amperometric devices, colorimetric, fluorescence and luminescence sensors have the advantages of simple structure, low cost, and portable design usually without power operation.
“Compared to amperometric devices, colorimetric, fluorescence and luminescence sensors have the advantages of simple structure, low cost, and portable design usually without power operation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAn FBG sensor used for radial artery pulse waveform measurement achieved a sensitivity of 8.236 nm/N.
“Jia et al. [252] used an FBG sensor for the radial artery pulse waveform measurement and achieved a sensitivity of 8.236 nm/N.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [252] Jia, 2018, A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
Probably not a substantial claim: may not pass S1 (asserted), S3 (load-bearing). May combine two claims.
PremisecitationA plate FBG sensor mounted inside a seat cushion can monitor HR with a maximum error of ±3 bpm and RR with ±1.2 rpm.
“In the next research, the plate FBG sensor is mounted inside the cushion, which is on the back of the seat and HR monitoring with a maximum error of ±3 bpm and RR with ±1.2 rpm is possible [262].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [262] Dziuda, 2013, Fiber Bragg grating-based sensor for monitoring respiration and heart activity during magnetic resonance imaging examinations, J. Biomed. Opt. source
Not checked in the free run.
May combine two claims.
InterpretationcitationThese materials and structures can be used as cost-effective colorimetric chemical detection devices for biochemical analysis methods or can substitute expensive spectrometers.
“These materials and structures can be used as cost-effective colorimetric chemical detection devices for biochemical analysis methods or can substitute expensive spectrometers [287].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [287] Ho, 2019, Tunable, Cost-Effective, and Scalable Structural Colors for Sensing and Consumer Products, Adv. Opt. Mater. source
Not checked in the free run.
May combine two claims.
PremisecitationA double-stranded Bragg grating wearable system monitors neck movements and breathing activity, and when tested on five subjects, RR was monitored with percentage errors of ≤6.09% and ≤1.90% during silent tachypnea breathing.
“Another multiparametric wearable system based on a double-stranded Bragg grating is monitoring neck movements and breathing activity [267]. The sensing elements were placed on the neck, in the frontal and sagittal planes. The system was tested on five subjects and RR was monitored with percentage errors of ≤6.09% and ≤1.90%, during silent tachypnea breathing.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [267] Presti, D.L., Carnevale, A., D’Abbraccio, J., Massari, L., Massaroni, C., Sabbadini, R., Zaltieri, M., Di Tocco, J., Bravi, M., and Miccinilli, S. (2020). A multi-parametric wearable system to monitor neck movements and respiratory frequency of computer workers. Sensors, 20. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.
Interpretationnone givenFluorescence analysis provides short response times, minimal instrumentation requirements, and overall low cost.
“Fluorescence analysis provides short response times, minimal instrumentation requirements, and overall low cost.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenOptical sensors are widely usable in various types of devices for measuring a wide range of physiological parameters.
“It is obvious that optical sensors are widely usable in various types of devices for measuring a wide range of physiological parameters.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationCompared to colorimetry, fluorescence-based protein assays have advantages such as rapid assay time, higher stability, better detection sensitivity, and can examine multiple analytes simultaneously.
“Compared to colorimetry, fluorescence-based protein assays have advantages such as rapid assay time, higher stability, better detection sensitivity, and can examine multiple analytes simultaneously [316].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [316] Singh, M., Truong, J., Reeves, W.B., and Hahm, J.I. (2017). Emerging cytokine biosensors with optical detection modalities and nanomaterial-enabled signal enhancement. Sensors, 17. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAthletes have improved their performance through the use of optical sensors.
“For example, athletes have improved their performance [332].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [332] Koydemir, 2018, Wearable and Implantable Sensors for Biomedical Applications, Annu. Rev. Anal. Chem. source
Not checked in the free run.
Probably not a substantial claim: may not pass S4 (based).
Interpretationnone givenThe use of optical sensors can help reduce healthcare costs through the continuous monitoring of physiologically important parameters.
“The use of optical sensors can help reduce healthcare costs through the continuous monitoring of physiologically important parameters.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationNanomaterials may be a suitable component of flexible sensors and increase scanning performance, but it is still not entirely clear whether they are completely biocompatible and non-toxic to cells.
“Nanomaterials may also be a suitable component of flexible sensors and increase scanning performance, but it is still not entirely clear whether they are completely biocompatible and non-toxic to cells [203].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [203] Hatamie, 2020, Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring, J. Electrochem. Soc. source
Not checked in the free run.
May combine two claims.
InterpretationcitationA general challenge of using optical fiber sensors is damage of the system while locating it in the field or within its working lifetime, which must be controlled and requires further research.
“On the other hand, a general challenge of using optical fiber sensors could be damage of the system while locating it in the field or within its working lifetime which must be controlled and requires further research in this area [331].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [331] Ferreira, 2017, Roadmap on optical sensors, J. Opt. source
Not checked in the free run.
Probably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).
InterpretationcitationUltimately, all research leads to more stable, accurate, robust sensing mechanisms and components that will withstand long-term use.
“Ultimately, all research leads to more stable, accurate, robust sensing mechanisms and components that will withstand long-term use [203].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [203] Hatamie, 2020, Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring, J. Electrochem. Soc. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenThe main disadvantage of colorimetry is that colorimetric tests exist only for a relatively narrow range of biomarkers.
“The main disadvantage of colorimetry is that colorimetric tests exist only for a relatively narrow range of biomarkers.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationnone givenInterference of ambient light with signal measurements and short penetration depth into the skin and other bioliquids are drawbacks of optical bio-sensors that limit their widespread use in the biosensing area.
“However, the interference of ambient light with signal measurements, the short penetration depth into the skin and other bioliquids are some of the drawbacks of optical bio-sensors that limit their widespread use in the biosensing area.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable), S4 (based). May combine two claims.
Interpretationnone givenDue to their many benefits, optical sensors are highly preferred in wearable electronics and are the future of telemedicine.
“Due to their many benefits, they are highly preferred in wearable electronics and are the future of telemedicine.”
Quote in the paperNot a substantial claim
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
PPG monitors blood flow in real time.
“photoplethysmography (PPG), which monitors blood flow in real time.130”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Mattress and pediatric fiber-sensor references are swapped
MinorThe prose assigns the macrobending mat to [226] and the pediatric microbending sensor to [227]. Table 3 assigns those applications the opposite references.
“The first sensing device is a mat embedded with a macro bending optical fiber sensor [226]. The second and third are microbending fiber optic sensors for perioperative pediatric vital signs monitoring placed under a barrier sheet on the operating table that was tested on 10 subjects [227]”
“| Mattress | HR, RR | Macrobend small core OF | High vibration sensitivity,reliability, and good stability | [227] | | Pediatric vital signs | HR, RR | Microbend fiber optic sensor under barrier sheet | Mash structure,monitoring of babies | [226] |”
Study [269] is described as two different sensor applications
MinorThe prose says Xiang et al. [269] studied pressure in a pneumatic compression device, whereas Table 3 labels [269] a nasal-airflow sensor.
“Xiang et al. [269] examined the pressure in a pneumatic compression therapy device.”
“| Nasal flow | RR | FBGs, cantilevers | Nasal airflow into a cantilever | [269] |”
Reference [314] is attributed to incompatible studies
MinorOne passage attributes [314] to Ozcan's urine-albumin device; another attributes it to Lim et al.'s transcutaneous oxygen-pressure sensor.
“In further research by Lim et al. [314] transcutaneous O2 pressure was monitored.”
“Ozcan’s group [314] has developed a portable smartphone-based device to measure albumin concentration in urine.”
Patch [304] measures sweat in the prose but wounds in the table
MinorThe prose identifies the [304] hydrogel patch as a sweat detector; Table 4 describes the same patch's analytes as being measured in wounds.
“They presented a flexible, self-healable, adhesive, and wearable hydrogel patch for on-demand sweat colorimetric detection usable in point-of-care diagnostics and personalized medicine.”
“| Smart bandage with wireless connectivity | pH, glucose, Ca2+ in wounds | Flexible, self-healable, adhesive and wearable hydrogel patch for on-demand sweat colorimetric detection | Smartphone based, pH (4–9), glucose (0–2 mM), Cl− (0–100 mM) and Ca2+ (0–16 mM) | [304] |”
Humidity-sensor response is given as milliseconds and meters
MinorFor the same [274] sensor, the prose reports a response time of about 42 ms, while Table 3 reports "42 m," a length rather than a time.
“Thus, it offers an ultrafast response within ∼42 ms and a sensitivity of 18.5 pm/%RH and 0.027 dB/%RH”
“| Breathhumidity monitor | RRrelative humidity | Needle, which houses graphene oxide deposited FBG sensor | Response ∼42 m, Sensitivities 18.5 pm/%RH, 0.027 dB/%RH (30∼80%RH) | [274] |”
T-shirt has two FBGs in the prose but three in Table 3
MinorThe prose describes the T-shirt sensors, including [249], as having two FBGs; the Table 3 entry for [249] says three.
“commercial T-shirts equipped with a single fiber optic housing two FBGs for RR and HR waves’ monitoring, where the FBGs were glued on the textile with silicone rubber were reported [249,250,251].”
“| T-shirt | HR, RR | Three FBGs glued on the textile with silicone rubber | Highly stretchableand compressible | [249] |”
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 1× · see citing works
“It is possible to use progressive neural learning methods [103,104], FFT-based neural networks [105], or Poincare section analysis [106].”
MethodAn overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185 · see citing works
The path to ubiquitous and low-cost organic electronic appliances on plastic
Forrest, S. R. (2004) · Nature · doi:10.1038/nature02498 · Cited by 5,186 · see citing works
Li, G., Zhu, R., & Yang, Y. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.11 · Cited by 4,416 · see citing works
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Canonical Correlation Analysis: An Overview with Application to Learning Methods
Hardoon, D. R., Szedmák, S., & Shawe-Taylor, J. S. (2004) · Neural Computation · doi:10.1162/0899766042321814 · Cited by 3,297 · cited 1× · see citing works
“It is possible to use progressive neural learning methods [103,104], FFT-based neural networks [105], or Poincare section analysis [106].”
MethodHighly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · see citing works
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · see citing works
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396 · see citing works
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296 · cited 2× · see citing works
“Early accurate diagnosis is the key to maintaining a high quality of life [1,2].”
BackgroundUltrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626 · see citing works
Structural Changes in Muscle During Contraction: Interference Microscopy of Living Muscle Fibres
HUXLEY, A. F., & NIEDERGERKE, R. (1954) · Nature · doi:10.1038/173971a0 · Cited by 1,608 · see citing works
Subwavelength-diameter silica wires for low-loss optical wave guiding
Tong, L., Gattass, R. R., Ashcom, J. B., He, S., Lou, J., Shen, M., Maxwell, I. Z., & Mazur, E. (2003) · Nature · doi:10.1038/nature02193 · Cited by 1,511 · see citing works
A bioinspired flexible organic artificial afferent nerve
Kim, Y., Chortos, A., Xu, W., Liu, Y., Oh, J. Y., Son, D., Kang, J., Foudeh, A. M., Zhu, C., Lee, Y., et al. (2018) · Science · doi:10.1126/science.aao0098 · Cited by 1,466 · see citing works
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408 · cited 1× · see citing works
“Early accurate diagnosis is the key to maintaining a high quality of life [1,2].”
BackgroundHighly stretchable electroluminescent skin for optical signaling and tactile sensing
Larson, C., Peele, B., Li, S., Robinson, S., Totaro, M., Beccai, L., Mazzolai, B., & Shepherd, R. (2016) · Science · doi:10.1126/science.aac5082 · Cited by 1,393 · see citing works
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274 · see citing works
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247 · cited 2× · see citing works
“Sensor for a skin evaluation Glucose level C8 MediSensors Raman spectroscopy sensor [7]”
BackgroundRationale and challenges for optical interconnects to electronic chips
Miller, D. A. B. (2000) · Proceedings of the IEEE · doi:10.1109/5.867687 · Cited by 1,189 · cited 1× · see citing works
“These limitations can be avoided by using photons as a signal carrier [32].”
BackgroundInflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181 · see citing works
Ash, C., Dubec, M., Donne, K., & Bashford, T. (2017) · Lasers in Medical Science · doi:10.1007/s10103-017-2317-4 · Cited by 1,040 · see citing works
Ultraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024 · see citing works
Fibre Bragg gratings in structural health monitoring—Present status and applications
Majumder, M., Gangopadhyay, T. K., Chakraborty, A. K., Dasgupta, K., & Bhattacharya, D. K. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.04.008 · Cited by 975 · see citing works
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · see citing works
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919 · cited 4× · see citing works
“The temperature is affected by blood circulation, HR, stress, metabolism, and external microclimatic factors [44].”
BackgroundMethodInfluentialBandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761 · cited 3× · see citing works
“simultaneous electrochemical, colorimetric, and volumetric analysis of sweat [21]; (k) Contact lens”
BackgroundMethodInfluentialWang, Z., Liu, M., Yan, W., Song, H., Zhou, Z., Yuen, K., Wei, Q., & Cheng, S. S. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3123218 · Cited by 678 · see citing works
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673 · see citing works
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625 · see citing works
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624 · see citing works
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603 · see citing works
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · cited 7× · see citing works
“All wearable biochemical sensors have some limitations, such as frequent calibration, readout drift due to biofouling, and biweekly sensor replacement [11].”
BackgroundMethodInfluentialPassive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566 · see citing works
Zhu, Y., Zhang, J., Song, J., Yang, J., Du, Z., Zhao, W., Guo, H., Wen, C., Li, Q., Sui, X., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201905493 · Cited by 544 · see citing works
All-dielectric metasurface for high-performance structural color
Yang, W., Xiao, S., Song, Q., Liu, Y., Wu, Y., Wang, S., Yu, J., Han, J., & Tsai, D.-P. (2020) · Nature Communications · doi:10.1038/s41467-020-15773-0 · Cited by 543 · see citing works
Wearable sensors for monitoring the physiological and biochemical profile of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0150-9 · Cited by 537 · see citing works
Circadian rhythms, sleep, and the menstrual cycle
Baker, F. C., & Driver, H. S. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2006.09.011 · Cited by 529 · see citing works
Fiber Bragg grating sensors for monitoring of physical parameters: a comprehensive review
Sahota, J. K., Gupta, N., & Dhawan, D. (2020) · Optical Engineering · doi:10.1117/1.oe.59.6.060901 · Cited by 526 · see citing works
Fibre Bragg Grating Based Strain Sensors: Review of Technology and Applications
Campanella, C. E., Cuccovillo, A., Campanella, C. E., Yurt, A., & Passaro, V. M. N. (2018) · Sensors · doi:10.3390/s18093115 · Cited by 522 · see citing works
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520 · see citing works
Non-plasmonic nanoantennas for surface enhanced spectroscopies with ultra-low heat conversion
Caldarola, M., Albella, P., Cortés, E., Rahmani, M., Roschuk, T., Grinblat, G., Oulton, R. F., Bragas, A. V., & Maier, S. A. (2015) · Nature Communications · doi:10.1038/ncomms8915 · Cited by 520 · see citing works
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513 · cited 2× · see citing works
“The trend began with simple fitness straps and developed rapidly in the form of variable advanced health accessories such as watches, smart clothing, glasses, contact lenses, rings, and various body extensions and inserts [5,6].”
BackgroundMultiparameter Respiratory Rate Estimation From the Photoplethysmogram
Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2246160 · Cited by 486 · see citing works
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452 · cited 2× · see citing works
“Monitoring cardiorespiratory activities using a PPG signal is a well-established non-invasive technique [44,93].”
MethodPhotoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450 · see citing works
Plasmonic colour laser printing
Zhu, X., Vannahme, C., Højlund-Nielsen, E., Mortensen, N. A., & Kristensen, A. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.285 · Cited by 441 · see citing works
Noninvasive monitoring of peripheral perfusion
Lima, A., & Bakker, J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2790-2 · Cited by 431 · see citing works
Heart-Rate Variability—More than Heart Beats?
Ernst, G. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00240 · Cited by 416 · see citing works
Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387 · see citing works
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371 · cited 3× · see citing works
“The newer representatives include, for example, where the sensor is built onto commercial contact lenses (Figure 1k) [22].”
BackgroundMethodInfluentialPhotonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · cited 3× · see citing works
“Photonic crystals formed by a face-centered cubic arrangement of colloidal particles in a hydrogel are applied for non-invasive glucose sensing [47].”
BackgroundChoi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365 · see citing works
Young, A. R. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/004 · Cited by 350 · see citing works
Nanophotonic Structural Colors
Rezaei, S. D., Dong, Z., Chan, J. Y. E., Trisno, J., Ng, R. J. H., Ruan, Q., Qiu, C., Mortensen, N. A., & Yang, J. K. W. (2020) · ACS Photonics · doi:10.1021/acsphotonics.0c00947 · Cited by 345 · see citing works
Printing Beyond sRGB Color Gamut by Mimicking Silicon Nanostructures in Free-Space
Dong, Z., Ho, J., Yu, Y. F., Fu, Y. H., Paniagua-Dominguez, R., Wang, S., Kuznetsov, A. I., & Yang, J. K. W. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b03613 · Cited by 335 · see citing works
Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A. R., Han, S., Jang, K., Lee, J. W., et al. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201604373 · Cited by 334 · cited 3× · see citing works
“A very promising design is the flexible concept (Figure 1a) [12], which incorporates advanced optoelectronic functions for PPG wireless NFC monitoring applications, including SpO2, HR, and HRV.”
BackgroundMethodInfluentialFever, fever patterns and diseases called “fever”—A review
Ogoina, D. (2011) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2011.05.002 · Cited by 305 · see citing works
Flexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galán, T., Gupta, S., Marques, M. M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 299 · cited 9× · see citing works
“Additional green LEDs associated with PDs measure blood density in the vessels on changes in transmittance.”
BackgroundInfluentialWearable and Implantable Sensors for Biomedical Applications
Koydemir, H. C., & Özcan, A. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125956 · Cited by 296 · see citing works
Biswas, D., Everson, L. R., Liu, M., Panwar, M., Verhoef, B.-E., Patki, S., Kim, C. H., Acharyya, A., Hoof, C. A. V., Konijnenburg, M., et al. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2892297 · Cited by 293 · see citing works
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285 · see citing works
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278 · see citing works
Gao, L. H., Zhang, Y., Malyarchuk, V., Jia, L., Jang, K., Webb, R. C., Fu, H., Shi, Y., Zhou, G., Shi, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5938 · Cited by 271 · see citing works
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 263 · cited 1× · see citing works
“It is possible to use progressive neural learning methods [103,104], FFT-based neural networks [105], or Poincare section analysis [106].”
MethodSynaptic dysfunction in Alzheimer's disease: Mechanisms and therapeutic strategies
Chen, Y., Fu, A. K. Y., & Ip, N. Y. (2019) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2018.11.006 · Cited by 258 · see citing works
Promphet, N., Rattanawaleedirojn, P., Siralertmukul, K., Soatthiyanon, N., Potiyaraj, P., Thanawattano, C., Hinestroza, J. P., & Rodthongkum, N. (2018) · Talanta · doi:10.1016/j.talanta.2018.09.086 · Cited by 254 · see citing works
Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography
Mendelson, Y., & Ochs, B. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7286 · Cited by 251 · see citing works
Easy‐to‐Fabricate Conducting Polymer Microelectrode Arrays
Sessolo, M., Khodagholy, D., Rivnay, J., Maddalena, F., Gleyzes, M., Steidl, E., Buisson, B., & Malliaras, G. G. (2013) · Advanced Materials · doi:10.1002/adma.201204322 · Cited by 246 · see citing works
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242 · cited 3× · see citing works
“[23] developed a wearable fluorometric sensor in the form of a soft, skin-interfaced microfluidic system to detect Na+, Cl−, and zinc (Zn2+) from eccrine sweat(Figure 1l).”
BackgroundMethodInfluentialYin, D., Feng, J., Ma, R., Liu, Y.-F., Zhang, Y.-L., Zhang, X.-L., Bi, Y.-G., Chen, Q.-D., & Sun, H.-B. (2016) · Nature Communications · doi:10.1038/ncomms11573 · Cited by 236 · see citing works
Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S. M., Wu, Y., Lau, K. T., Wallace, G. G., & Diamond, D. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 234 · see citing works
Optical Fiber Sensors Embedded Into Medical Textiles for Healthcare Monitoring
Grillet, A., Kinet, D., Witt, J., Schukar, M., Krebber, K., Pirotte, F., & Depré, A. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.926518 · Cited by 234 · see citing works
Trung, T. Q., Le, H. S., Dang, T. M. L., Ju, S., Park, S. Y., & Lee, N. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800074 · Cited by 232 · see citing works
Roda, A., Michelini, E., Cevenini, L., Calabria, D., Calabretta, M. M., & Simoni, P. (2014) · Analytical Chemistry · doi:10.1021/ac502137s · Cited by 222 · see citing works
Wearable System Based on Flexible FBG for Respiratory and Cardiac Monitoring
Lo Presti, D., Massaroni, C., D'Abbraccio, J., Massari, L., Caponero, M., Longo, U. G., Formica, D., Oddo, C. M., & Schena, E. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2916320 · Cited by 219 · see citing works
Estimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation
Chon, K. H., Dash, S., & Ju, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019766 · Cited by 213 · cited 1× · see citing works
“, which uses variablefrequency complex demodulation and provides slightly better results [94,95].”
ResultPolymer Optical Fiber Sensors in Healthcare Applications: A Comprehensive Review
Junior, A. G. L., Díaz, C. A. R., Avellar, L. M., Pontes, M. J., Marques, C., & Frizera, A. (2019) · Sensors · doi:10.3390/s19143156 · Cited by 212 · see citing works
Curto, V. F., Fay, C., Coyle, S. M., Byrne, R. J., O’Toole, C., Barry, C., Hughes, S. M., Moyna, N. M., Diamond, D., & Benito‐Lopez, F. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.06.048 · Cited by 211 · see citing works
Albumin testing in urine using a smart-phone
Coskun, A. F., Nagi, R., Sadeghi, K., Phillips, S. W., & Özcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50785h · Cited by 210 · see citing works
Wearable Organic Optoelectronic Sensors for Medicine
Bansal, A. K., Hou, S., Kulyk, O., Bowman, E. M., & Samuel, I. D. W. (2015) · Advanced Materials · doi:10.1002/adma.201403560 · Cited by 205 · cited 3× · see citing works
“The myosin protein in muscle sarcomeres has liquid crystalline properties and is responsible for the anisotropic behavior of muscles [39].”
BackgroundMethodInfluentialWearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200 · cited 2× · see citing works
“Wrist-worn Glucose level, HR Four x LED (OSRAM SFH7060 and Vishay VSMY2853), PD (400–1000 nm) Wavelengths 530, 660, 850, 950 nm, 24 features from 10 s frames, Partial least squares calibration algorithm [92]”
MethodNon-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare
Yoon, Y.-Z., Cho, J. H., & Yoon, G. (2008) · Journal of Medical Systems · doi:10.1007/s10916-008-9186-0 · Cited by 199 · see citing works
Lmberis, A., & Dittmar, A. (2007) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2007.364926 · Cited by 194 · see citing works
Ultrasensitive skin-like wearable optical sensors based on glass micro/nanofibers
Zhang, L., Pan, J., Zhang, Z., Wu, H., Yao, N., Cai, D., Xu, Y., Zhang, J., Sun, G., Wang, L., et al. (2020) · Opto-Electronic Advances · doi:10.29026/oea.2020.190022 · Cited by 186 · see citing works
Review—Textile Based Chemical and Physical Sensors for Healthcare Monitoring
Hatamie, A., Angizi, S., Kumar, S., Pandey, C. M., Simchi, A., Willander, M., & Malhotra, B. D. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab6827 · Cited by 184 · see citing works
Caldara, M., Colleoni, C., Guido, E., Re, V., & Rosace, G. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.073 · Cited by 181 · see citing works
Infrared camera assessment of skin surface temperature—Effect of emissivity
Bernard, V., Staffa, E., Mornstein, V., & Bourek, A. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.09.003 · Cited by 177 · see citing works
Soft Wearable Systems for Colorimetric and Electrochemical Analysis of Biofluids
Ghaffari, R., Choi, J., Raj, M. S., Chen, S., Lee, S. P., Reeder, J. T., Aranyosi, A. J., Leech, A., Li, W., Schon, S., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201907269 · Cited by 173 · see citing works
Medical Smart Textiles Based on Fiber Optic Technology: An Overview
Massaroni, C., Saccomandi, P., & Schena, E. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6020204 · Cited by 172 · see citing works
Smartphone based optical biosensor for the detection of urea in saliva
Soni, A., Surana, R. K., & Jha, S. K. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.108 · Cited by 170 · see citing works
Photoplethysmography and Deep Learning: Enhancing Hypertension Risk Stratification
Liang, Y., Chen, Z., Ward, R. K., & Elgendi, M. (2018) · Biosensors · doi:10.3390/bios8040101 · Cited by 170 · see citing works
Stretchable and Highly Sensitive Optical Strain Sensors for Human-Activity Monitoring and Healthcare
Guo, J., Zhou, B., Zong, R., Pan, L., Li, X., Yu, X., Yang, C., Kong, L., & Dai, Q. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09815 · Cited by 170 · see citing works
Wearable sensors : fundamentals, implementation and applications
Sazonov, E. E., & Neuman, M. R. (2014) · doi:10.1016/c2018-0-01225-6 · Cited by 169 · see citing works
A Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring
Fajkus, M., Nedoma, J., Martínek, R., Vašinek, V., Nazeran, H., & Šiška, P. (2017) · Sensors · doi:10.3390/s17010111 · Cited by 169 · see citing works
Medical Textiles With Embedded Fiber Optic Sensors for Monitoring of Respiratory Movement
Witt, J., Narbonneau, F., Schukar, M., Krebber, K., Jonckheere, J. D., Jeanne, M., Kinet, D., Paquet, B., Depré, A., D’Angelo, L., et al. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2158416 · Cited by 167 · cited 3× · see citing works
“Chest belt RR FBG sensor Tested wavelengths 525, 660, 850, 1310, 1550 nm [18]”
BackgroundMethodInfluentialInfrared Thermal Imaging for Automated Detection of Diabetic Foot Complications
van Netten, J. J., van Baal, J. G., Liu, C., van der Heijden, F., & Bus, S. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700504 · Cited by 164 · see citing works
Automatic detection of diabetic foot complications with infrared thermography by asymmetric analysis
Liu, C., van Netten, J. J., van Baal, J. G., Bus, S. A., & van der Heijden, F. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.2.026003 · Cited by 163 · see citing works
Li, K. H. C., White, F. A., Tipoe, T., Liu, T., Wong, M. C. S., Jesuthasan, A., Baranchuk, A. M., Tse, G., & Yan, B. P. (2018) · JMIR mhealth and uhealth · doi:10.2196/11606 · Cited by 162 · cited 1× · see citing works
“PDs and the LEDs must be optically isolated [78], for example, using a raised mesa, and the whole optical system must be surrounded by optical separation techniques to reduce the impact of ambient light [79].”
MethodCore Temperature Measurement—Principles of Correct Measurement, Problems, and Complications
Hymczak, H., Gołąb, A., Mendrala, K., Plicner, D., Darocha, T., Podsiadło, P., Hudziak, D., Gocoł, R., & Kosiński, S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182010606 · Cited by 161 · see citing works
Smartphone-assisted personalized diagnostic devices and wearable sensors
Purohit, B., Kumar, A., Mahato, K., & Chandra, P. (2020) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.08.015 · Cited by 159 · see citing works
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · cited 3× · see citing works
“Proper hydration is important and therefore measurements and warnings of non-compliance can help prevent the associated problems [45].”
BackgroundLee, J., Kim, M., Park, H.-K., & Kim, I. Y. (2020) · Sensors · doi:10.3390/s20051493 · Cited by 153 · cited 2× · see citing works
“Wrist-worn reflectance LED Motion artifact reduction PP: Four x OSRAM SFH7050, Motion Sensor: InvenSense MPU9250 Wavelengths 530, 660, 940 nm [75]”
BackgroundSensitive and Wearable Optical Microfiber Sensor for Human Health Monitoring
Li, J., Chen, J., & Xu, F. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800296 · Cited by 151 · see citing works
In vivo reflectance of blood and tissue as a function of light wavelength
Cui, W., Ostrander, L. E., & Lee, B. Y. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55667 · Cited by 149 · cited 1× · see citing works
“Since the maxima of the pulsating component of the reflected light occurs in the range between 510 and 590 nm [68], the green (565 nm) or yellow (590 nm) light is usually used [69].”
BackgroundQuandt, B. M., Scherer, L. J., Boesel, L. F., Wolf, M., Bona, G. L., & Rossi, R. M. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400463 · Cited by 148 · see citing works
Two-Dimensional Material-Based Colorimetric Biosensors: A Review
Zhu, D., Liu, B., & Wei, G. (2021) · Biosensors · doi:10.3390/bios11080259 · Cited by 147 · see citing works
Schrödinger’s red pixel by quasi-bound-states-in-the-continuum
Dong, Z., Jin, L., Rezaei, S. D., Wang, H., Chen, Y., Tjiptoharsono, F., Ho, J., Gorelik, S. R., Ng, R. J. H., Ruan, Q., et al. (2022) · Science Advances · doi:10.1126/sciadv.abm4512 · Cited by 147 · see citing works
Rundo, F., Conoci, S., Ortis, A., & Battiato, S. (2018) · Sensors · doi:10.3390/s18020405 · Cited by 143 · cited 2× · see citing works
“PPG probe PPG and ECG pattern OSRAM LT M673 LEDs, STMicroelectronics SiPM detector Wavelength 529 nm [77]”
MethodKinetic investigation into pH-dependent color of anthocyanin and its sensing performance
Tang, B., He, Y., Liu, J., Zhang, J., Li, J., Zhou, J., Ye, Y., Wang, J., & Wang, X. (2019) · Dyes and Pigments · doi:10.1016/j.dyepig.2019.107643 · Cited by 143 · see citing works
Ciocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2015) · Biosensors · doi:10.3390/bios5030602 · Cited by 142 · see citing works
Optical trapping and manipulation of micrometer and submicrometer particles
Daly, M., Sergides, M., & Chormaic, S. N. (2015) · Laser & Photonics Review · doi:10.1002/lpor.201500006 · Cited by 140 · see citing works
Ferreira, M. F. S., Castro-Camus, E., Ottaway, D. J., Higuera, J. M. L., Feng, X., Jin, W., Jeong, Y., Picqué, N., Tong, L., Reinhard, B. M., et al. (2017) · Journal of Optics · doi:10.1088/2040-8986/aa7419 · Cited by 140 · see citing works
Smart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation
Massaroni, C., Venanzi, C., Silvatti, A. P., Lo Presti, D., Saccomandi, P., Formica, D., Giurazza, F., Caponero, M. A., & Schena, E. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700263 · Cited by 139 · see citing works
Chen, H.-Y., Chen, A., & Chen, C. (2020) · Sensors · doi:10.3390/s20102885 · Cited by 139 · see citing works
Smart bandage with wireless connectivity for optical monitoring of pH
Kassal, P., Zubak, M., Scheipl, G., Mohr, G. J., Steinberg, M. D., & Steinberg, I. M. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.095 · Cited by 136 · see citing works
Effect of body fat and gender on body temperature distribution
Neves, E. B., Salamunes, A. C. C., de Oliveira, R. M., & Stadnik, A. M. W. (2017) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2017.10.017 · Cited by 136 · see citing works
Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring
Hosanee, M., Chan, G., Welykholowa, K., Cooper, R., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C., Lovell, N. H., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030723 · Cited by 136 · cited 1× · see citing works
“Many algorithms are known where systolic and diastolic BP are estimated from the shape of the PPG curve [55,102].”
BackgroundThe Application of Medical Infrared Thermography in Sports Medicine
Hildebrandt, C., Zeilberger, K., Ring, E. F. J., & Raschner, C. (2012) · InTech eBooks · doi:10.5772/28383 · Cited by 135 · see citing works
Flexible, self-healable, adhesive and wearable hydrogel patch for colorimetric sweat detection
Wang, L., Xu, T., He, X., & Zhang, X. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc03905a · Cited by 135 · see citing works
Jiang, B., Bi, Z., Hao, Z., Yuan, Q., Feng, D., Zhou, K., Zhang, L., Gan, X., & Zhao, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.05.024 · Cited by 133 · see citing works
Guo, J., Zhao, K., Zhou, B., Wen, N., Jiang, K., Yang, C., Kong, L., & Dai, Q. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900086 · Cited by 129 · see citing works
Guo, J., Yang, C., Dai, Q., & Kong, L. (2019) · Sensors · doi:10.3390/s19173771 · Cited by 129 · see citing works
Bierman, A., Klein, T. R., & Rea, M. S. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/11/023 · Cited by 128 · see citing works
Li, H., Yang, H., Li, E., Liu, Z., & Wei, K. (2012) · Optics Express · doi:10.1364/oe.20.011740 · Cited by 128 · see citing works
Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2988692 · Cited by 128 · see citing works
An Optical Fibre-Based Sensor for Respiratory Monitoring
Krehel, M., Schmid, M., Rossi, R. M., Boesel, L. F., Bona, G. L., & Scherer, L. J. (2014) · Sensors · doi:10.3390/s140713088 · Cited by 127 · see citing works
Hardy, J. D., & Muschenheim, C. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100624 · Cited by 127 · see citing works
Smart textile using hetero-core optical fiber for heartbeat and respiration monitoring
Koyama, Y., Nishiyama, M., & Watanabe, K. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2847333 · Cited by 126 · see citing works
Lo Presti, D., Romano, C., Massaroni, C., D’Abbraccio, J., Massari, L., Caponero, M. A., Oddo, C. M., Formica, D., & Schena, E. (2019) · Sensors · doi:10.3390/s19163581 · Cited by 126 · see citing works
Application of infrared thermography in computer aided diagnosis
Faust, O., Acharya, U. R., Ng, E. Y. K., Hong, T. J., & Yu, W. (2014) · Infrared Physics & Technology · doi:10.1016/j.infrared.2014.06.001 · Cited by 122 · see citing works
Dziuda, Ł., Skibniewski, F. W., Krej, M., & Baran, P. M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.057006 · Cited by 121 · see citing works
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119 · see citing works
Data Fusion for Improved Respiration Rate Estimation
Nemati, S., Malhotra, A., & Clifford, G. D. (2010) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2010/926305 · Cited by 115 · see citing works
Jia, M., Chew, W. M., Feinstein, Y., Skeath, P., & Sternberg, E. M. (2016) · The Analyst · doi:10.1039/c5an02387d · Cited by 113 · see citing works
Organic Multi-Channel Optoelectronic Sensors for Wearable Health Monitoring
Khan, Y., Han, D., Ting, J., Ahmed, M., Nagisetty, R., & Arias, A. C. (2019) · IEEE Access · doi:10.1109/access.2019.2939798 · Cited by 111 · cited 3× · see citing works
“Wrist-worn printed organic HR, SpO2 OLED 2, OPD 3 multichannel PPG Wavelengths: Red and IR [74]”
BackgroundMethodInfluentialGökalp, H., & Clarke, M. (2013) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2013.0109 · Cited by 110 · cited 1× · see citing works
“Monitoring of childhood obesity is known, where accelerometers offer objective measurement of normal activity independently of self-report [48,49], or the monitoring of seniors in in-home care, where the system records their activities, events, and potentially important health symptoms [50,51].”
BackgroundElmesmari, R., Martin, A., Reilly, J. J., & Paton, J. Y. (2018) · BMC Pediatrics · doi:10.1186/s12887-018-1031-0 · Cited by 108 · cited 1× · see citing works
“Monitoring of childhood obesity is known, where accelerometers offer objective measurement of normal activity independently of self-report [48,49], or the monitoring of seniors in in-home care, where the system records their activities, events, and potentially important health symptoms [50,51].”
BackgroundMulti-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107 · see citing works
Xiao, G., He, J., Qiao, Y., Wang, F., Xia, Q., Wang, X., Yu, L. D., Lu, Z., & Li, C. M. (2020) · Advanced Fiber Materials · doi:10.1007/s42765-020-00046-8 · Cited by 107 · see citing works
Xu, X., & Yan, B. (2018) · Journal of Materials Chemistry C · doi:10.1039/c7tc05204a · Cited by 101 · see citing works
Dell’Isola, G. B., Cosentini, E., Canale, L., Ficco, G., & Dell’Isola, M. (2021) · Sensors · doi:10.3390/s21020346 · Cited by 101 · see citing works
A Wearable Reflectance Pulse Oximeter for Remote Physiological Monitoring
Mendelson, Y., Duckworth, R. J., & Comtois, G. (2006) · doi:10.1109/iembs.2006.260137 · Cited by 99 · see citing works
Human motion monitoring in sports using wearable graphene-coated fiber sensors
Zhang, J., Cao, Y., Qiao, M., Ai, L., Sun, K., Mi, Q., Zang, S., Zuo, Y., Yuan, X., & Wang, Q. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.03.011 · Cited by 97 · see citing works
Reflectance pulse oximetry: Practical issues and limitations
Lee, H., Ko, H., & Lee, J. (2016) · ICT Express · doi:10.1016/j.icte.2016.10.004 · Cited by 95 · see citing works
Zhao, Z., Li, Q., Chen, L., Yu, Z., Gong, J., Li, Z., & Zhang, J. (2020) · Lab on a Chip · doi:10.1039/d0lc01075h · Cited by 95 · see citing works
Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip
Ryu, G., Huang, J., Hofmann, O., Walshe, C. A., Sze, J. Y. Y., McClean, G. D., Mosley, A., Rattle, S. J., deMello, J. C., deMello, A. J., et al. (2011) · Lab on a Chip · doi:10.1039/c0lc00586j · Cited by 93 · cited 2× · see citing works
“[36] where they demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications, consisting of 501 nm commercially available InGaN LED, an organic or silicon photodiode, absorptive dye-coated color filters, polarizers, and an injected polystyrene microfluidic chip.”
BackgroundTunable, Cost‐Effective, and Scalable Structural Colors for Sensing and Consumer Products
Rezaei, S. D., Ho, J., Naderi, A., Yaraki, M. T., Wang, T., Dong, Z., Ramakrishna, S., & Yang, J. K. W. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900735 · Cited by 92 · see citing works
Sandberg, M., Zhang, Q., STYF, J. R., Gerdle, B. U. C., & Lindberg, L. (2005) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2005.01412.x · Cited by 91 · cited 1× · see citing works
“Body-worn reflectance LED PPG Skin and muscle perfusion Eight x LED, Three x PD line/circle configuration Wavelengths 560, 880 nm [61]”
BackgroundPresti, D. L., Carnevale, A., D’Abbraccio, J., Massari, L., Massaroni, C., Sabbadini, R., Zaltieri, M., Tocco, J. D., Bravi, M., Miccinilli, S., et al. (2020) · Sensors · doi:10.3390/s20020536 · Cited by 91 · see citing works
Hofmann, O., Wang, X., de Mello, J. C., Bradley, D. D. C., & deMello, A. J. (2005) · Lab on a Chip · doi:10.1039/b504551g · Cited by 90 · cited 2× · see citing works
“research is the determination of urinary human serum albumin on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic LEDs with an emission wavelength of 540 nm [37].”
BackgroundWearable Devices for Environmental Monitoring in the Built Environment: A Systematic Review
Salamone, F., Masullo, M., & Sibilio, S. (2021) · Sensors · doi:10.3390/s21144727 · Cited by 89 · see citing works
Path-dependent human identification using a pyroelectric infrared sensor and fresnel lens arrays
Fang, J.-S., Hao, Q., Brady, D. J., Shankar, M., Guenther, B. D., Pitsianis, N. P., & Hsu, K. Y. (2006) · Optics Express · doi:10.1364/opex.14.000609 · Cited by 87 · see citing works
Kazanskiy, N. L., Butt, M. A., & Khonina, S. N. (2022) · Nanomaterials · doi:10.3390/nano12030334 · Cited by 87 · cited 2× · see citing works
“Older methodologies based on invasive sampling with the use of heavy equipment are nowadays being transformed into simple scanning methods that do not require demanding manipulation and also make people feel more comfortable [3].”
BackgroundIs thermal scanner losing its bite in mass screening of fever due to SARS?
Ng, E. Y. ‐. (2005) · Medical Physics · doi:10.1118/1.1819532 · Cited by 86 · see citing works
Self‐Assembled Wavy Optical Microfiber for Stretchable Wearable Sensor
Zhu, H., Zhan, L., Dai, Q., Xu, B., Chen, Y., Lu, Y., & Xu, F. (2021) · Advanced Optical Materials · doi:10.1002/adom.202002206 · Cited by 85 · see citing works
Barreto, H. P., Morales-Hernandez, L. A., Rangel‐Magdaleno, J., Avina‐Cervantes, J. G., Ramírez-Cortés, J. M., & Caporal, R. M. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/585306 · Cited by 84 · see citing works
A Gelated Colloidal Crystal Attached Lens for Noninvasive Continuous Monitoring of Tear Glucose
Ruan, J.-L., Chen, C., Shen, J., Zhao, X., Qian, S., & Zhu, Z. (2017) · Polymers · doi:10.3390/polym9040125 · Cited by 83 · see citing works
Yang, B., Kong, J., & Fang, X. (2019) · Talanta · doi:10.1016/j.talanta.2019.06.031 · Cited by 83 · see citing works
Ozana, N., Arbel, N., Beiderman, Y., Mico, V., Sanz, M., Garcia, J., Anand, A., Javidi, B., Epstein, Y., & Zalevsky, Z. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001926 · Cited by 81 · see citing works
A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement
Jia, D., Jing, C., Li, S., Zhang, H., Yan, Y., Liu, T., & Sun, Y. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2722008 · Cited by 81 · see citing works
Fiber-Optic Based Smart Textiles for Real-Time Monitoring of Breathing Rate
Issatayeva, A., Beisenova, A., Tosi, D., & Molardi, C. (2020) · Sensors · doi:10.3390/s20123408 · Cited by 81 · see citing works
Robertson, W., Stewart-Brown, S. L., Wilcock, E., Oldfield, M., & Thorogood, M. (2010) · Journal of Obesity · doi:10.1155/2011/398918 · Cited by 80 · cited 1× · see citing works
“Monitoring of childhood obesity is known, where accelerometers offer objective measurement of normal activity independently of self-report [48,49], or the monitoring of seniors in in-home care, where the system records their activities, events, and potentially important health symptoms [50,51].”
BackgroundComparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · cited 1× · see citing works
“The PPG signal, when recorded in a real environment, often contains movement artifacts and is also affected by the changing pressure of the sensor on the skin [80].”
BackgroundPigliautile, I., & Pisello, A. L. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.02.208 · Cited by 77 · see citing works
Optical Sensor for Real-Time pH Monitoring in Human Tissue
Wencel, D., Kaworek, A., Abel, T., Efremov, V., Bradford, A., Carthy, D., Coady, G., McMorrow, R. C. N., & McDonagh, C. (2018) · Small · doi:10.1002/smll.201803627 · Cited by 77 · see citing works
Wang, J., & Dong, J. (2020) · Sensors · doi:10.3390/s20143981 · Cited by 77 · see citing works
Intensity-Modulated Microbend Fiber Optic Sensor for Respiratory Monitoring and Gating During MRI
Lau, D., Chen, Z., Teo, J. T., Ng, S. H., Rumpel, H., Lian, Y., Yang, H. M., & Kei, P. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2262150 · Cited by 76 · see citing works
Wireless wearable wristband for continuous sweat pH monitoring
Escobedo, P., Ramos-Lorente, C. E., Martínez-Olmos, A., Carvajal, M. A., Ortega‐Muñoz, M., de Orbe-Payá, I., Mateo, F. H., Santoyo‐González, F., Capitán-Vallvey, L. F., Palma, A. J., et al. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128948 · Cited by 76 · see citing works
Marchionni, P., Scalise, L., Ercoli, I., & Tomasini, E. P. (2013) · Review of Scientific Instruments · doi:10.1063/1.4845635 · Cited by 75 · see citing works
Aitkulov, A., & Tosi, D. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894834 · Cited by 74 · see citing works
Singh, M., Truong, J., Reeves, W. B., & Hahm, J. (2017) · Sensors · doi:10.3390/s17020428 · Cited by 72 · see citing works
Thermometry and interpretation of body temperature
Chen, W. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00102-2 · Cited by 72 · see citing works
Noninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress
Wang, S., Ni, X., Li, L., Wang, J., Liu, Q., Yan, Z., Zhang, L., & Sun, Q. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974313 · Cited by 71 · see citing works
Pulse-Glasses: An unobtrusive, wearable HR monitor with Internet-of-Things functionality
Constant, N. P., Douglas-Prawl, O., Johnson, S., & Mankodiya, K. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299350 · Cited by 70 · cited 2× · see citing works
“Glasses HR Reflectance PPG on the nose [84]”
MethodEstimation of respiration rate from ECG, BP and PPG signals using empirical mode decomposition
Madhav, K. V., Ram, M. R., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2011) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/imtc.2011.5944249 · Cited by 70 · cited 1× · see citing works
“Pulse wave amplitudes are affected by the blood vessel flexibility, the variation in pulse shape, and a decrease in intrathoracic pressure that leads to increased venous return during inspiration [96,97].”
BackgroundLow-cost plastic optical fiber sensor embedded in mattress for sleep performance monitoring
Han, P., Li, L., Zhang, H., Guan, L., Marques, C., Savović, S., Ortega, B., Min, R., & Xiaoli Li, A. (2021) · Optical Fiber Technology · doi:10.1016/j.yofte.2021.102541 · Cited by 69 · see citing works
Infrared thermal imaging in connective tissue diseases
Chojnowski, M. M. (2017) · Reumatologia/Rheumatology · doi:10.5114/reum.2017.66686 · Cited by 67 · see citing works
Pang, Y.-N., Liu, B., Liu, J., Wan, S. P., Wu, T., He, X., Yuan, J., Zhou, X., Long, K., & Wu, Q. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3032646 · Cited by 67 · see citing works
A Wristwatch-Based Wireless Sensor Platform for IoT Health Monitoring Applications
Kumar, S., Buckley, J. L., Barton, J. J., Pigeon, M., Newberry, R., Rodencal, M., Hajzeraj, A., Hannon, T., Rogers, K., Casey, D. P., et al. (2020) · Sensors · doi:10.3390/s20061675 · Cited by 66 · see citing works
Impact of Ocular Surface Temperature on Tear Characteristics: Current Insights
Shah, A., & Galor, A. (2021) · Clinical Optometry · doi:10.2147/opto.s281601 · Cited by 66 · see citing works
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64 · see citing works
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64 · see citing works
Noninvasive continuous optical monitoring of absolute cerebral blood flow in critically ill adults
He, L., Baker, W. B., Milej, D. F., Kavuri, V. C., Mesquita, R. C., Busch, D. R., Abramson, K., Jiang, J. Y., Diop, M., Lawrence, K. S., et al. (2018) · Neurophotonics · doi:10.1117/1.nph.5.4.045006 · Cited by 63 · see citing works
Law, J., Chalmers, J., Morris, D. E., Robinson, L., Budge, H., & Symonds, M. E. (2017) · Temperature · doi:10.1080/23328940.2017.1397085 · Cited by 62 · see citing works
Non-invasive human vital signs monitoring based on twin-core optical fiber sensors
Tan, F., Chen, S., Lyu, W., Liu, Z., Yu, C., Lu, C., & Tam, H.-Y. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005940 · Cited by 62 · see citing works
Deep convolutional neural networks for classifying breast cancer using infrared thermography
Torres‐Galván, J. C., Guevara, E., Kolosovas‐Machuca, E. S., Oceguera‐Villanueva, A., Flores, J. L., & González, F. J. (2021) · Quantitative InfraRed Thermography Journal · doi:10.1080/17686733.2021.1918514 · Cited by 61 · see citing works
In vivo investigation of ear canal pulse oximetry during hypothermia
Budidha, K., & Kyriacou, P. A. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-9975-4 · Cited by 60 · see citing works
Patterned, Wearable UV Indicators from Electrospun Photochromic Fibers and Yarns
Zheng, Y., Panatdasirisuk, W., Liu, J., Tong, A., Xiang, Y., & Yang, S. M. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000564 · Cited by 59 · see citing works
Yan, T., Zhang, G., Chai, H., Qu, L., & Zhang, X. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.753692 · Cited by 59 · see citing works
Vega, K. C., Jiang, N., Liu, X., Kan, V., Barry, N., Maes, P., Yetisen, A. K., & Paradiso, J. A. (2017) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3123021.3123039 · Cited by 59 · see citing works
Fluorescent Measurement in the Non-Invasive Contact Lens Glucose Sensor
March, W., Lazzaro, D., & Rastogi, S. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.312 · Cited by 58 · see citing works
Blanik, N., Abbas, A. K., Venema, B., Blazek, V., & Leonhardt, S. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.016012 · Cited by 58 · see citing works
Marzorati, D., Bovio, D., Salito, C., Mainardi, L. T., & Cerveri, P. (2020) · IEEE Access · doi:10.1109/access.2020.2981300 · Cited by 57 · cited 2× · see citing works
“Chest reflectance LED PPG sensor HR, BP from PPG and PCG PPG: Osram SFH 7060, PCG 1 NXP Semiconductors MPXV7002 Wavelengths 3 × 530, 660, 950 nm [56]”
BackgroundMethodKhaksari, K., Nguyen, T., Hill, B. Y., Perrault, J., Gorti, V., Blick, E., Gonzalez Cano, T., Shadgan, B., Quang, T., Malpani, R., et al. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.s1.010901 · Cited by 55 · see citing works
Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring
Sartiano, D., & Sales, S. (2017) · Sensors · doi:10.3390/s17122900 · Cited by 54 · see citing works
Comparison of machine learning strategies for infrared thermography of skin cancer
Magalhaes, C., Tavares, J. M. R. S., Mendes, J. G., & Vardasca, R. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102872 · Cited by 54 · see citing works
Quandt, B. M., Braun, F., Ferrario, D., Rossi, R. M., Scheel‐Sailer, A., Wolf, M., Bona, G. L., Hufenus, R., Scherer, L. J., & Boesel, L. F. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0060 · Cited by 52 · see citing works
L’Her, E., Nguyen, Q.-T., Pateau, V., Bodénes, L., & Lellouche, F. (2019) · Annals of Intensive Care · doi:10.1186/s13613-019-0485-z · Cited by 52 · cited 2× · see citing works
“This calibration achieved noise-free HR detection [78].”
MethodJonckheere, J. D., Jeanne, M., Grillet, A., Weber, S., Chaud, P., Logier, R., & Weber, J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353198 · Cited by 51 · see citing works
Rundo, F., Ortis, A., Battiato, S., & Sabrina Conoci, A. (2018) · Computation · doi:10.3390/computation6030046 · Cited by 51 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Reşit Kavsaoglu, A., Polat, K., Recep Bozkure, M., and Muthusamy, H. (2013, January 24–26). Fotopletismografi sinyalleri ile biyometrik tanlmaya yönelik özellilk çlkarlml. Proceedings of the 2013 21st Signal Processing and Communications Applications Conference (SIU), Haspolat, Turkey.
- Ghosh, 2005, Development of a sensor-embedded flexible textile structure for apparel or large area applications, Indian J. Fibre Text. Res., 30, 42
Cited by
Sorted by citations
Rasheed, S., Kanwal, T., Ahmad, N., Fatima, B., Haq, M. N. U., & Hussain, D. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117640 · Cited by 220 · see citing works
Novel Wearable Optical Sensors for Vital Health Monitoring Systems—A Review
Kaur, B., Kumar, S., & Kaushik, B. K. (2023) · Biosensors · doi:10.3390/bios13020181 · Cited by 152 · see citing works
“BRPE are nucleic acids (NA), proteins, and synthetically designed polymer receptors [8,10].”
BackgroundRecent progress of bio-based smart wearable sensors for healthcare applications
Banitaba, S. N., Khademolqorani, S., Jadhav, V. V., Chamanehpour, E., Mishra, Y. K., Mostafavi, E., & Kaushik, A. K. (2023) · Materials Today Electronics · doi:10.1016/j.mtelec.2023.100055 · Cited by 124 · see citing works
Advances in self-powered sports monitoring sensors based on triboelectric nanogenerators
Sun, F., Zhu, Y., Jia, C., Zhao, T., Chu, L., & Mao, Y. (2023) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2022.12.024 · Cited by 114 · see citing works
Chen, H., Wang, L., Liu, S., Sheng, X., & Yin, L. (2024) · ACS Nano · doi:10.1021/acsnano.3c11832 · Cited by 110 · see citing works
Triboelectric nanogenerators for wearable sensing applications: A system level analysis
Bulathsinghala, R. L., Ding, W. K., & Dharmasena, R. D. I. G. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108792 · Cited by 109 · see citing works
Setchfield, K., Gorman, A., Simpson, A. H. R. W., Somekh, M. G., & Wright, A. J. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.1.010901 · Cited by 72 · see citing works
“130 Differences in the interaction of light with human tissues at differing wavelengths is exploited to provide information including oxygen saturation, blood pressure, and more recently other cardio-vascular-related diseases.”
BackgroundParupelli, S. K., & Desai, S. S. (2023) · Bioengineering · doi:10.3390/bioengineering11010032 · Cited by 65 · see citing works
Alsahag, M., Alisaac, A., Al‐Hazmi, G. A. A., Pashameah, R. A., Attar, R. M. S., Saad, F. A., & El‐Metwaly, N. M. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.10.119 · Cited by 60 · see citing works
Li, Y., Guo, Y., Chen, H., Xiao, X., Long, F., Zhong, H., Wang, K., Guo, Z., Zhuang, Z., & Liu, Z. (2024) · ACS Photonics · doi:10.1021/acsphotonics.3c01490 · Cited by 53 · see citing works
Flexible Optical Fiber Sensing: Materials, Methodologies, and Applications
Gan, J., Yang, A., Guo, Q., & Yang, Z. (2024) · Advanced Devices & Instrumentation · doi:10.34133/adi.0046 · Cited by 44 · see citing works
Bio-inspired electronic sensors for healthcare applications
Pal, S., Kumar, D., Ulucan‐Karnak, F., Narang, J., & Shukla, S. K. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.155894 · Cited by 36 · see citing works
Optical sensors for transdermal biomarker detection: A review
Amjad, A., & Xian, X. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116844 · Cited by 37 · see citing works
Almawgani, A. H. M., Wekalao, J., Kumar, U. A., Patel, S. K., Alkorbi, A. S., Jalalah, M., & Harraz, F. A. (2024) · Plasmonics · doi:10.1007/s11468-024-02613-w · Cited by 30 · see citing works
“Such instruments are built to detect and measure various parameters of light, including intensity, wavelength, and polarization, among others [6].”
Optical biosensing systems for a biological living body
Yan, T., Guo, C., Wang, C., & Zhu, K. (2023) · Open Research (University of Surrey) · doi:10.1002/viw.20220059 · Cited by 29 · see citing works
Kara, G., Bolat, S., Sharma, K., Grotevent, M. J., Dirin, D. N., Bachmann, D., Furrer, R., Boesel, L. F., Romanyuk, Y. E., Rossi, R. M., et al. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201922 · Cited by 29 · see citing works
Recent Advances in Triplet–Triplet Annihilation Upconversion for Bioimaging and Biosensing
Lin, W., Li, J., Feng, H., Qi, F., & Huang, L. F. (2023) · Journal of Analysis and Testing · doi:10.1007/s41664-023-00264-0 · Cited by 27 · see citing works
“There are numerous applications for optical oxygen sensors in biomedicine [106], healthcare [107], biotechnology [108], marine research, and manufacturing [109].”
Toward Wearable Sensors: Advances, Trends, and Challenges
He, T., Chen, J., He, B., Wang, W. W., Zhu, Z., & Lv, Z. (2023) · ACM Computing Surveys · doi:10.1145/3596599 · Cited by 28 · see citing works
“Optical sensors used in wearable devices mainly include optical iber sensors, luorescence sensors, and semiconductor nanowire-based optical sensors [124].”
BackgroundBelabbaci, N. A., Anaadumba, R., & Alam, M. A. U. (2025) · JMIR mhealth and uhealth · doi:10.2196/60569 · Cited by 28 · see citing works
Label-Free Micro Probe Optical Fiber Biosensor for Selective and Highly Sensitive Glucose Detection
Li, X., Gong, P., Zhang, Y., & Zhou, X. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3219464 · Cited by 24 · see citing works
“Especially its good biocompatibility, a large number of studies have proved that optical fiber can be directly used in vivo therapy [19], [20], [21], [22], such as optical fiber endoscope [23], optical fiber diagnosis [24], and optical fiber therapy system [25].”
BackgroundWekalao, J., Alsalman, O., & Patel, S. K. (2025) · Measurement · doi:10.1016/j.measurement.2025.117812 · Cited by 23 · see citing works
Duarah, R., Torné‐Morató, H., Zhang, G., Amin, Y., Pabast, M., Sharma, N., He, S., Das, M. R., & Pompa, P. P. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202504419 · Cited by 24 · see citing works
Ban, S., Yi, H., Park, J., Huang, Y., Yu, K. J., & Yeo, W. (2025) · Advanced Materials · doi:10.1002/adma.202416899 · Cited by 22 · see citing works
Artificial Intelligence for Noninvasive Health Diagnostics
Wankhede, P., Bhuyar, D. L., Zanwar, S. R., Pawar, R., Jadhav, M. R., Gandhewar, N., Kulkarni, M. B., Bhaiyya, M. L., & Haick, H. (2025) · ACS Sensors · doi:10.1021/acssensors.5c03171 · Cited by 24 · see citing works
Cho, Y., Park, M., Shin, Y. J., Kim, Y. W., Jeong, J., Cho, E., Kwon, S. J., & Jeon, Y. (2024) · ACS Photonics · doi:10.1021/acsphotonics.4c01870 · Cited by 20 · see citing works
Bissen, A., Yunussova, N., Myrkhiyeva, Z., Salken, A., Tosi, D., & Bekmurzayeva, A. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1401613 · Cited by 20 · see citing works
“The length of the grating can be 10 mm Vavrinsky et al. (2022) TFBG/Plasmonic TFBG - Similar to FBG but the grating is tilted -Thetiltangledictateswhichcladding modesareexcited and therefore the operating range of the sensor -”
BackgroundFrom Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 20 · see citing works
“Heart rate variability (HRV), which represents beat-to-beat variations in heart rate, is widely used for stress assessment, autonomic nervous system analysis, and recovery tracking [111], while fitness wearables leverage heart rate zones to personalize exercise intensity levels [112].”
Yang, M., Sun, N., Lai, X., Zhao, X., & Zhou, W. (2023) · Biosensors · doi:10.3390/bios14010017 · Cited by 18 · see citing works
Highly Sensitive Plasmon Refractive Index Sensor Based on MIM Waveguide
Jiang, W., Yan, S., Yan, X., Xu, A., Liu, G., Wang, C., Li, L., Mu, X., & Gao, G. (2024) · Micromachines · doi:10.3390/mi15080987 · Cited by 18 · see citing works
“Photonic devices exhibit superior immunity to electromagnetic interference [4], operating bandwidth [5], long-distance transmission, and low power consumption in comparison to electronic devices [6].”
BackgroundLow voltage driven P3HT/PS phototransistor for ultra-high power efficiency UV sensing
Agrahari, K., Han, M., Priya, S. L., Cheng, Y. H., & Wang, Y. (2024) · Organic Electronics · doi:10.1016/j.orgel.2024.107033 · Cited by 16 · see citing works
Optical Contact Lenses Biosensors
Xia, X., Hu, Y., Jiang, N., & Yetisen, A. K. (2025) · ACS Sensors · doi:10.1021/acssensors.5c01222 · Cited by 17 · see citing works
Advancements in 3D-printed wearable sensors: a modern healthcare
Vaishnav, K. N., Verma, R. P., & Saha, B. (2025) · Materials Today · doi:10.1016/j.mattod.2025.08.006 · Cited by 13 · see citing works
Asghar, K., Ngulimi, M. F., Kim, S., Seo, B. K., Bertrand, G. H. V., & Roh, C. (2025) · Progress in Materials Science · doi:10.1016/j.pmatsci.2025.101616 · Cited by 13 · see citing works
Respiratory Rate Extraction from Neonatal Near-Infrared Spectroscopy Signals
Hakimi, N., Shahbakhti, M., Horschig, J. M., Alderliesten, T., van Bel, F., Colier, W. N. J. M., & Dudink, J. (2023) · Sensors · doi:10.3390/s23094487 · Cited by 13 · see citing works
Zhu, J., He, W., Li, S., Li, Z., & Zhu, L. (2023) · Applied Optics · doi:10.1364/ao.494967 · Cited by 13 · see citing works
Recent Advances in Flexible Multifunctional Sensors
Chang, Y., Qi, X., Wang, L., Li, C., & Wang, Y. (2023) · Micromachines · doi:10.3390/mi14112116 · Cited by 14 · see citing works
“Particularly, flexible optical sensors [26] and electrical impedance tomography (EIT) technology [27] rely on light matter interactions.”
BackgroundMonazah, S. M. M., & Salehi, M. R. (2023) · Optical Materials · doi:10.1016/j.optmat.2023.114747 · Cited by 13 · see citing works
Effect of temperature on GaN-integrated optical transceiver chips
Yan, J., Fang, L., Yan, Y., Sun, Z., Shi, F., Shi, Z., & Wang, Y. (2024) · Optics Letters · doi:10.1364/ol.525315 · Cited by 11 · see citing works
Review: Comparison of traditional and modern diagnostic methods in breast cancer
Elaibi, H. K., Mutlag, F. F., Halvacı, E., Aygün, A., & Şen, F. (2024) · Measurement · doi:10.1016/j.measurement.2024.116258 · Cited by 11 · see citing works
Ear‐Area Soft Electronics for Advanced Healthcare Monitoring
Yu, Y., Zhang, H., Pan, X., Yuan, M., Sun, Y., Han, P., Fang, Q., Li, B., Xu, F., & Fang, Y. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202505046 · Cited by 10 · see citing works
Watch-Type Dual-Mode Wearable Health Device
Park, H., Nguyen, L. H. T., Lakshminarayana, S., Sun, Y., & Jung, S. (2023) · ECS Sensors Plus · doi:10.1149/2754-2726/acc74d · Cited by 10 · see citing works
Soft and Stretchable Conductive Polymers for Next‐Generation Wearable Biosensing
Afshar, H., Kamran, F., Moshiri, H., & Shahi, F. (2026) · Polymer Engineering and Science · doi:10.1002/pen.70335 · Cited by 9 · see citing works
“In optical biosensing, biochemical interactions alter the refractive index, light absorption, or fluorescence, and these changes are converted into quantifiable signals [170, 171].”
Optical Properties of Light-Scattering Standards for CCD Photometry
Bondariev, D., Bezugla, N., Komada, P., Stelmakh, N. V., & Bezuglyi, M. A. (2023) · Sensors · doi:10.3390/s23187700 · Cited by 8 · see citing works
“…(for example, pulse oximetry and oxygen sensors [4], bilirubinometry [5], blood glucometry [6]), in turn, uses the results of spectroscopic studies and uses one or more wavelengths in the applied quantitative analysis [7,8], which allows monitoring of the physical or metabolic indicator level.”
BackgroundRecent development in wearable sensors for healthcare applications
Saeedi, F., Ansari, R., & Haghgoo, M. (2025) · Nano-Structures & Nano-Objects · doi:10.1016/j.nanoso.2025.101473 · Cited by 9 · see citing works
Continuous biosignal acquisition beyond the limit of epidermal turnover
Bhatia, A., Kasper, K. A., & Gutruf, P. (2025) · Materials Horizons · doi:10.1039/d5mh00758e · Cited by 7 · see citing works
Bharathan, D. C., Wagterveld, R. M., Chah, K., Caucheteur, C., & Offerhaus, H. L. (2025) · Optical Fiber Technology · doi:10.1016/j.yofte.2025.104361 · Cited by 7 · see citing works
Zhang, C., Yan, H., Liu, Q., Yang, K., Liu, F., & Lin, L. (2024) · IEEE Transactions on Molecular Biological and Multi-Scale Communications · doi:10.1109/tmbmc.2023.3349326 · Cited by 7 · see citing works
“The optical detection method based on blood oxygen saturation measurement is quite mature and has strong feasibility [17], but the idea of applying it to communication inside and outside the human body is still proposed for the first time.”
MethodThe Impact of AI on the Development of Multimodal Wearable Devices in Musculoskeletal Medicine
Olson, G. L., Hansmann-Canas, I., Karimi, Z., Yazdkhasti, A., Shabestanipour, G., Ghaednia, H., & Schwab, J. H. (2025) · HSS Journal® The Musculoskeletal Journal of Hospital for Special Surgery · doi:10.1177/15563316251344945 · Cited by 6 · see citing works
Trimodal Watch-Type Wearable Health Monitoring Device
Lakshminarayana, S., Ranganatha, M., Park, H., & Jung, S. (2024) · Applied Sciences · doi:10.3390/app14209267 · Cited by 6 · see citing works
Photonic integrated interrogators for wearable fiber-optic sensing
Lin, Z., Wang, R., Chrostowski, L., & Cai, X. (2024) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2024.108396 · Cited by 7 · see citing works
Tian, X., Shen, C., Liu, Y., Zhang, T., Liang, L., Li, J., Ma, D., Wang, J., & Qin, J. (2024) · Journal of Lightwave Technology · doi:10.1109/jlt.2024.3443206 · Cited by 5 · see citing works
“immunity to electromagnetic interference, and the ability to multiplex [1], [2], [3].”
Computational Model-Assisted Development of a Nonenzymatic Fluorescent Glucose-Sensing Assay
Colvin, L. E., Husseini, D. A., Tu, D., Dunlap, D., Lalonde, T. J., Üçüncü, M., Megía-Fernández, A., Bradley, M., Liu, W. R., Grunlan, M. A., et al. (2024) · ACS Sensors · doi:10.1021/acssensors.4c02117 · Cited by 5 · see citing works
Optical Biosensors—Principles of Operation and Applications
Błachowicz, T., Ehrmann, G., Stepula, E., & Ehrmann, A. (2026) · Micromachines · doi:10.3390/mi17050579 · Cited by 5 · see citing works
“Vavrinsky et al. concentrated on optical biosensors in medical wearables and highlighted their immunity to electromagnetic interference, electrical safety and simple miniaturization [240].”
Wearable Optical Sensors: Toward Machine Learning-Enabled Biomarker Monitoring
Faham, S., Faham, S., & Sepehri, B. (2024) · Chemistry Africa · doi:10.1007/s42250-024-01047-5 · Cited by 6 · see citing works
“Several sensing modalities can detect biomarkers using optical and electrochemical methods, as well as physical methods [1, 114].”
Optical Fiber Sensing Technology for Sports Monitoring: A Comprehensive Review
Li, L. T., Luo, Y., Wang, R., Huo, D., Song, B., Yu, H., & Zhou, Y. F. (2025) · Photonics · doi:10.3390/photonics12100963 · Cited by 6 · see citing works
Design of exergames controlled by wearable devices for sensorimotor skills: a framework proposal
Ferreira, D. R. D. M. J., de Lima, T. F. M., de Assis, G. A., Ruivo, E., Rodrigues, B. D. S., & Corrêa, A. G. D. (2022) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah54908.2022.9978550 · Cited by 5 · see citing works
“For instance, optical sensors embedded in watches or wristbands can monitor vital signs (e.g., heart and respiratory rates, blood pressure) [9].”
BackgroundXuan, S. N., Wekalao, J., Mahalakshmi, P., & Raja, M. R. (2025) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/adf88c · Cited by 4 · see citing works
Smart e-Textile Singlet Prototype and Concept: Multi Sensor Sensing for Geriatric Monitoring
Steinmetzer, T., Wieczorek, F., Naake, A., Wolf, P., Braun, A., & Michel, S. C. A. (2025) · Bioengineering · doi:10.3390/bioengineering12111275 · Cited by 4 · see citing works
“Several commercial systems have demonstrated the feasibility of forearm-based SpO 2 monitoring [23], although motion artifacts and ambient light interference remain challenges in wearable applications.”
Na, Y., Kim, C., Kim, K., Kim, T. H., Kwon, S. H., Kang, I., Jung, Y. W., Kim, T. W., Cho, D.-H., An, J., et al. (2024) · Biosensors · doi:10.3390/bios14020109 · Cited by 4 · see citing works
Design and Simulation of Tunneling Diodes with 2D Insulators for Rectenna Switches
Li, E., Raju, P., & Zhao, E. (2024) · Materials · doi:10.3390/ma17040953 · Cited by 4 · see citing works
“The current wearable electronics are often equipped with visible lights, e.g., green and red lights, to perform the biomedical measurement [11].”
BackgroundA Highly Improved Long-Range BDTS for Nuclear Reactors Using Hybrid Algorithm
Pradhan, H. S., Mahajan, P., Vislawath, N., & Prasad, V. S. D. N. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3298353 · Cited by 4 · see citing works
“consumer and medical uses [1], [2], [3].”
Real-Time Wheelchair Controller Based on POF-Based Pressure Sensors
González-Cely, A. X., Blanco-Díaz, C. F., Díaz Camilo, A. R., & Bastos-Filho, T. (2023) · IEEE Latin American Electron Devices Conference (LAEDC) · doi:10.1109/laedc58183.2023.10209115 · Cited by 4 · see citing works
“The literature review also presents the use of instrumentation based on Optical Fiber Sensors (OFS) for different biomedical applications [15], [16].”
BackgroundYi, 唐. T., Zhiyu, 冯. F., Yu, 成. C., Ming, 陈. C., Houquan, 刘. L., Hongchang, 邓. D., Chuanxin, 滕. T., Shijie, 邓. D., & Libo, 苑. Y. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop231641 · Cited by 3 · see citing works
Integrated light field sensors: From nanophotonic architectures to computational perception
Zheng, Z.-H., Chen, Y., Luo, S., Chen, Z., & Chen, J. (2026) · Applied Physics Reviews · doi:10.1063/5.0289443 · Cited by 3 · see citing works
Kharcheva, A. V., Shmelkov, K. D., Sokolovskaya, Y. G., Ivanov, A. V., Borisova, N. E., & Patsaeva, S. V. (2024) · Moscow University Physics Bulletin · doi:10.3103/s0027134924700620 · Cited by 2 · see citing works
Real-time minimalist imaging via spatial aberration uniformization and re-parameterized restoration
Zhang, H., Shi, R., Wei, R., & Bai, J. (2026) · Optics Express · doi:10.1364/oe.592056 · Cited by 2 · see citing works
Shukla, P. K., Akanbi, O. A., Asakipaam, S. A., Aljaedi, A., Bouye, M., & Sharma, S. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/7307552 · Cited by 2 · see citing works
“PPG epochs that were at least 30 seconds long were utilized in a number of validation procedures; nonetheless, shorter recordings are preferable for utilization in clinical applications [24].”
MethodDemodulation of CFBG With a Microwave Photonic Filter for Temperature-Insensitive Strain Measurement
Wang, Y., Zhou, Y., Zhu, W., Zhang, J., Liu, Z., & Wang, D. (2023) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2023.3339197 · Cited by 2 · see citing works
“F IBER optical sensors have wide applications in the fields of national defense, urban construction, medicine, and aerospace due to their compact structure, high sensitivity, and anti-electromagnetic interference [1], [2], [3].”
BackgroundCurrent Innovative Methods of Fetal pH Monitoring—A Brief Review
Bohîlțea, R. E., Mihai, B.-M., Ducu, I., Cioca, A.-M., Bohiltea, A.-T., Iordache, A., Iordache, S.-M., Grigorescu, C. E. A., & Marinescu, S. A. (2022) · Diagnostics · doi:10.3390/diagnostics12112675 · Cited by 1 · see citing works
Zhang, J., Zhou, Y., Zhu, W., Wang, D., Wang, Y., & Liu, Z. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3561877 · Cited by 1 · see citing works
“Compared with electrical methods, optical strain measurements exhibit the features of high sensitivity, compact structure, and strong anti-electromagnetic interference capability [4], [5], [6], [7], [8], thus attracting significant attention in recent works.”
Remote Monitoring of Vital Signs
Cristina, S., Počta, P., Žgank, A., Camilleri, K. P., Colantonio, S., & Lambrinos, L. (2025) · Intelligent systems reference library · doi:10.1007/978-3-031-84158-3_8 · Cited by 1 · see citing works
Implanted Miniature Light Devices for Phototherapeutics
Sanders, H. S., Price, C. G., Barreto, A. F. D. A., Rho, S., O'Sullivan, T. D., & Smith, B. D. (2025) · Advances in Therapy · doi:10.1002/adtp.202500492 · Cited by 4 · see citing works
“As shown in Scheme 4, these challenges can be divided into four interconnected performance categories: power transfer, operational distance, optical output, and device biocompatibility.”
Reversible strain sensing via lanthanide-doped luminescent nanorods in flexible polymers
Minh, N. H., Zou, Q., Gacoin, T., Yoon, J. S., Wang, Z., & Kim, J. (2026) · Journal of Luminescence · doi:10.1016/j.jlumin.2026.121855 · Cited by 1 · see citing works
Yin, M., Huang, W., Guo, X., Zhao, Q., Ostojić, G., Loh, T. C., Hu, J., & Zhang, M. (2026) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2026.112175 · Cited by 1 · see citing works
Liu, J., Shi, M., Wang, X., Li, X., Wang, L., Huang, Y., & Yao, X. (2026) · Small Structures · doi:10.1002/sstr.70597 · Cited by 1 · see citing works
Ramasamy, V., Samiappan, D., & Ramesh, R. (2023) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2023.032155 · Cited by 1 · see citing works
Arduino and the Construction of a Height and Heart Rate Meter
Vera, A. A., González, J., & González, C. M. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-37117-2_4
Zhang, J., Zhou, Y., Wang, Y., & Wang, D. (2023) · Third Asia Pacific Optical Sensors Conference · doi:10.1117/12.2692226
“Fiber optical sensors have a wide range of applications in the fields of national defense, urban construction, and aerospace due to their compact structure, high sensitivity, and anti-electromagnetic interference [1-3].”
BackgroundStress Simulation of Polydimethylsiloxane-Coated Fiber Bragg Grating Bend Sensor
Razali, N. M., Saris, N. N. H., Sopian, S. A., Ramli, N. A., & Mirza, W. I. I. W. I. (2023) · Communications in computer and information science · doi:10.1007/978-981-99-7243-2_18
Getmanceva, N., Burka, A. V., Gadkevitch, S. V., Anatiychuk, V. V., & Besaha, R. M. (2024) · International Conference on Correlation Optics · doi:10.1117/12.3014245
“…continuous health monitoring as a cost-effective tool for use in many areas of healthcare - from preliminary examination, preliminary diagnosis and preliminary treatment 11 to remote monitoring, thereby enabling people to live longer, and most importantly, safely 12 and maintain their independence.”
BackgroundThe effect of substance concentration on the spectral information of a multi-spectral sensor
Kiattimongkol, N., Kiattimongkol, W., Chamniprasart, K., Phunpeng, V., & Uangpairoj, P. (2024) · AIP conference proceedings · doi:10.1063/5.0214186
Papadopoulou, P., & Lytras, M. D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13619-1.00003-9
Kharcheva, A. V., Shmelkov, K. D., Sokolovskaya, Y. G., Ivanov, A. V., Borisova, N. E., & Patsaeva, S. V. (2024) · Vestnik Moskovskogo Universiteta Seriya 3 Fizika Astronomiya · doi:10.55959/msu0579-9392.79.2440402
Innovations in quantitative rapid testing: Early prediction of health risks
Alleilem, K. S., Almousa, S., Alissa, M., Alrumaihi, F., Alharbi, H. O., Almansour, N. M., Aldaiji, L. A., Abouzied, A. S., Alsugoor, M. H., Alasmari, O., et al. (2025) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2025.103000
Mannstadt, J., & Rahimi‐Iman, A. (2025) · Advanced Sensor Research · doi:10.1002/adsr.70009
Villalba-Díez, J., & González‐Marcos, A. (2025) · Scientific Reports · doi:10.1038/s41598-025-06359-1
High-precision Imaging Photoplethysmography-remote
Gomez-Gonzalez, N., Dominguez-Hernandez, S., Becerra-Martínez, L., Servin, M., & Páez, G. (2025) · Optics in the Life Sciences · doi:10.1364/boda.2025.jm4a.3
Morim, M. M., Rupper, P., Altenried, S., Meier, A., Rossi, R. M., Ren, Q., Boesel, L. F., & Giovannini, G. (2025) · Journal of Materials Chemistry B · doi:10.1039/d5tb01437a
Federated Learning-Based Stress Detection and Curative Recommendation System
Chawla, P., Das, A., Balai, N., Chhajed, J., & Shams, J. (2025) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-2577-5_12
Kala, D., Chakraborty, M., Sakowicz, M., Tiwari, P., & Staniszewska, M. (2025) · Smart nanomaterials technology · doi:10.1007/978-981-96-6091-9_1
Embodied Data: Exploring the Impact of Biometric Visualization Techniques on Global Health Equity
Ain, Q. U. (2026) · Biomedical visualization · doi:10.1007/978-3-032-12305-3_7
Karneluti, I., Joshy, D., Mohr, G. J., Schaude, C., Steinberg, M. D., & Steinberg, I. M. (2026) · Sensors · doi:10.3390/s26030880
Review of deep learning methods for imaging photoplethysmography data processing
Rubin, I. M., & Volynsky, M. A. (2026) · Scientific and technical journal of information technologies mechanics and optics · doi:10.17586/2226-1494-2026-26-2-236-249
Non-Contact Detection of Apnea-like Breathing Cessations Using Laser Speckle Pattern Analysis
Dutta, A., Shemer, A., Schwarz, A., Danan, Y., & Beiderman, Y. (2026) · Sensors · doi:10.3390/s26103042
Body‐integrated photonic biosensors: Illuminating the path to active healthcare
Gu, J., Wen, X., Yan, Q., ZHAO, Y., Yuan, L., Chen, S., Ma, Y., 方正月, Lei, D., Liu, Y., et al. (2026) · FlexMat. · doi:10.1002/flm2.70098
Daripa, B., Karmakar, D., Mondal, S., Das, S., & Dhar, A. (2026) · Plasmonics · doi:10.1007/s11468-026-03405-0
Guo, J., Li, S., Shi, Y., He, S., Bi, L., Zhang, J., & Zhao, D. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118368
Lavorgna, V., Gallinaro, M., Polimadei, A., D’Amato, R., Caponero, M. A., Presti, D. L., & Schena, E. (2026) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot69397.2026.11653102
“…measurements arises in several application areas, including human–machine interactions, tactile feedback, physiological and biomechanical monitoring, as well as in wearable devices, minimally invasive surgery, and other clinical procedures involving direct contact with the human body [3], [4], [5].”
Yu, H., Wang, T., Sun, S., Zhang, L., Chang, D., & Li, X. (2026) · Nanotechnology and Precision Engineering · doi:10.1063/5.0326482
Metamaterial-based wearable nanosensor for continuous cardiovascular health monitoring
Ran, Q., Liu, Y., Zhou, L., Zeng, Y., Zhang, J., & Zhou, X. (2026) · Materials Research Bulletin · doi:10.1016/j.materresbull.2026.114487
- Authors
- Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H.
- Affiliations
- Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 81219 Bratislava, Slovakia
- Slovak University of Technology in Bratislava (SK)
- Slovak Academy of Sciences (SK)
- Corresponding author
- Kosnacova, Helena
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2022-04-06
- Volume
- 12
- Issue
- 4
- Pages
- 217
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC9029995
- OpenAlex
- W4224239721
- Semantic Scholar
- 946af75b40694a578b46260de186850ec58e590b
- Cited by
- 103
- References
- 317
- Citations by year
- 2026: 21 · 2025: 26 · 2024: 28 · 2023: 23 · 2022: 5
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Research Agency of the Slovak Republic (ITMS code: 313011ASY8)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Keywords
- optical sensors, wearable medical devices, photoplethysmography, fiber optic sensors, biochemical sensors, radiation detectors, non-invasive physiological monitoring, telemedicine, home health monitoring, wearable biosensors
- MeSH terms
- Wearable Electronic Devices, Humans, Technology, Telemedicine, Optical Fibers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review