Ex Vivo Tumor‐on‐a‐Chip Platforms to Study Intercellular Interactions within the Tumor Microenvironment
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
The emergence of immunotherapies and recent FDA approval of several of them makes them a promising therapeutic strategy for cancer. While these advancements underscore the potential of engaging the immune system to target tumors, this approach has so far been efficient only for certain cancers. Extending immunotherapy as a widely acceptable treatment for various cancers requires a deeper understanding of the interactions of tumor cells within the tumor microenvironment (TME). The immune cells are a key component of the TME, which also includes other stromal cells, soluble factors, and extracellular matrix‐based cues. While in vivo studies function as a gold standard, tissue‐engineered microphysiological tumor models can offer patient‐specific insights into cancer‐immune interactions. These platforms, which recapitulate cellular and non‐cellular components of the TME, enable a systematic understanding of the contribution of each component toward disease progression in isolation and in concert. Microfluidic‐based microphysiological platforms recreating these environments, also known as “tumor‐on‐a‐chip,” are increasingly being utilized to study the effect of various elements of TME on tumor development. Herein are reviewed advancements in tumor‐on‐a‐chip technology that are developed and used to understand the interaction of tumor cells with other surrounding cells, including immune cells, in the TME.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the tumor immune microenvironment (TIME) for effective therapy
Binnewies, M., Roberts, E. W., Kersten, K., Chan, V., Fearon, D. F., Merad, M., Coussens, L. M., Gabrilovich, D. I., Ostrand-Rosenberg, S., Hedrick, C. C., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0014-x · Cited by 6,145
The biology and function of fibroblasts in cancer
Kalluri, R. (2016) · Nature Reviews Cancer · doi:10.1038/nrc.2016.73 · Cited by 4,366
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Mutations Associated with Acquired Resistance to PD-1 Blockade in Melanoma
Zaretsky, J. M., Garcia-Diaz, A., Shin, D. S., Escuin-Ordinas, H., Hugo, W., Hu-Lieskovan, S., Torrejon, D. Y., Abril-Rodriguez, G., Sandoval, S., Barthly, L., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1604958 · Cited by 3,237
CTLA-4 and PD-1 Pathways: Similarities, Differences, and Implications of Their Inhibition
Buchbinder, E. I., & Desai, A. (2016) · American Journal of Clinical Oncology · doi:10.1097/coc.0000000000000239 · Cited by 2,360
Drug Resistance and the Solid Tumor Microenvironment
Tredan, O., Galmarini, C. M., Patel, K., & Tannock, I. F. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm135 · Cited by 2,116
Cancer Invasion and the Microenvironment: Plasticity and Reciprocity
Friedl, P., & Alexander, S. (2011) · Cell · doi:10.1016/j.cell.2011.11.016 · Cited by 1,940
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Cox, T. R., & Erler, J. T. (2011) · Disease Models & Mechanisms · doi:10.1242/dmm.004077 · Cited by 1,569
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Cited by
Targeting Tumor Microenvironment for Cancer Therapy
Roma-Rodrigues, C., Mendes, R., Baptista, P. V., & Fernandes, A. R. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20040840 · Cited by 1,187
Tumor-on-a-chip: from bioinspired design to biomedical application
Liu, X., Fang, J., Huang, S., Wu, X., Xie, X., Wang, J., Liu, F., Zhang, M., Peng, Z., & Hu, N. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00277-8 · Cited by 246
Aung, A., Kumar, V., Theprungsirikul, J., Davey, S. K., & Varghese, S. (2020) · Cancer Research · doi:10.1158/0008-5472.can-19-0342 · Cited by 146
Self-citation
Metadata
- Authors
- Kumar, V., & Varghese, S.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-12-05
- Volume
- 8
- Issue
- 4
- Pages
- e1801198-e1801198
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2903458582
- Cited by
- 68
- References
- 53
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ex Vivo Tumor‐on‐a‐Chip Platforms to Study Intercellular Interactions within the Tumor Microenvironment. https://app.cochat.ai/papers/10.1002/adhm.201801198
- The paper
- Kumar, V., & Varghese, S. (2019). Ex Vivo Tumor‐on‐a‐Chip Platforms to Study Intercellular Interactions within the Tumor Microenvironment. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201801198
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.