A Wearable Sensor Using Structured Silver‐Particle Reinforced PDMS for Radial Arterial Pulse Wave Monitoring
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Human pulse signals contain important and useful physiological information for the auxiliary diagnosis of cardiovascular disease. Here, a wearable pulse sensor based on piezo‐thermic transduction is reported using a structured silver‐particle reinforced polydimethylsiloxane (PDMS) membrane, for monitoring radial arterial pulse waves. The structured silver‐particle reinforced PDMS membrane is optimally designed to meet the specific requirements on sensitivity, linearity, and effective preload measuring range for pulse detection by adjusting the air gap volume fraction and silver particle volume fraction of the structured material. The sensor is endowed with high sensitivity, good linearity in preload measuring range, allowing to detect the subtle pulse waveforms of subjects at different ages under different contact pressures, such as superficial (Fu), medium (Zhong) and deep (Chen). The developed pulse device provides a promising approach for homecare pulse monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection
Zang, Y., Zhang, F., Huang, D., Gao, X., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms7269 · Cited by 548
Electronic Skin with Multifunction Sensors Based on Thermosensation
Zhao, S., & Zhu, R. (2017) · Advanced Materials · doi:10.1002/adma.201606151 · Cited by 273
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationKhoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Fiber/Yarn and Textile-Based Piezoresistive Pressure Sensors
Yang, Y., Liu, Y., & Yin, R. (2025) · Advanced Fiber Materials · doi:10.1007/s42765-024-00479-5 · Cited by 110
“Artery pulse generates pressure around 200 Pa [58], and precise measurement needs sensitive linear response under specific preload (20–100 kPa) [59] and bandwidth (0.1–20 Hz) [60].”
InfluentialTemperature and Strain Compensation for Flexible Sensors Based on Thermosensation
Wang, L., Zhu, R., & Li, G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b21474 · Cited by 82
Self-citation
Metadata
- Authors
- Fu, Y., Zhao, S., Wang, L., & Zhu, R.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2019-07-10
- Volume
- 8
- Issue
- 17
- Pages
- e1900633-e1900633
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2959282602
- Cited by
- 58
- References
- 3
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wearable Sensor Using Structured Silver‐Particle Reinforced PDMS for Radial Arterial Pulse Wave Monitoring. https://app.cochat.ai/papers/10.1002/adhm.201900633
- The paper
- Fu, Y., Zhao, S., Wang, L., & Zhu, R. (2019). A Wearable Sensor Using Structured Silver‐Particle Reinforced PDMS for Radial Arterial Pulse Wave Monitoring. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201900633
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.