Cited by 36Cardiac Valve Diseases and TreatmentsTissue Engineering and Regenerative MedicineOrthopaedic implants and arthroplasty

Transcatheter Heart Valves: A Biomaterials Perspective

Bui, Hieu T., Khair, Nipa, Yeats, Breandan, Gooden, Shelley, James, Susan P., Dasi, Lakshmi Prasad·2021·Advanced Healthcare Materials

Abstract

Heart valve disease is prevalent throughout the world, and the number of heart valve replacements is expected to increase rapidly in the coming years. Transcatheter heart valve replacement (THVR) provides a safe and minimally invasive means for heart valve replacement in high‐risk patients. The latest clinical data demonstrates that THVR is a practical solution for low‐risk patients. Despite these promising results, there is no long‐term (>20 years) durability data on transcatheter heart valves (THVs), raising concerns about material degeneration and long‐term performance. This review presents a detailed account of the materials development for THVRs. It provides a brief overview of THVR, the native valve properties, the criteria for an ideal THV, and how these devices are tested. A comprehensive review of materials and their applications in THVR, including how these materials are fabricated, prepared, and assembled into THVs is presented, followed by a discussion of current and future THVR biomaterial trends. The field of THVR is proliferating, and this review serves as a guide for understanding the development of THVs from a materials science and engineering perspective.

Integrity signals

Registry

Crossref · 10.1002/adhm.202100115

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Incorporating different proportions of other materials into PLCL matrix improves mechanical strength to meet heart valve needs.

    “the researchers formed the new composite material by incorporating different proportions of other materials into the PLCL matrix to improve the mechanical strength of the material so that it can meet the needs of the heart valve [149, 171].”

The citation lists haven’t been fetched yet

References 258 · Cited by 36

Authors
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P.
Affiliations
  • Georgia Institute of Technology (US)
  • Colorado State University (US)
Corresponding author
Dasi, Lakshmi Prasad
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2021-05-26
Volume
10
Issue
15
Pages
e2100115-e2100115
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W3165393507
Cited by
36
References
258
Citations by year
2026: 7 · 2025: 12 · 2024: 7 · 2023: 5 · 2022: 5
FWCI
0.83
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Healthcare Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute for Health Research (1R01HL119824‐01)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
transcatheter heart valve, biomaterials, valvular heart disease, valve durability, material degradation, device fabrication, device testing, high-risk patients
MeSH terms
Aortic Valve, Biocompatible Materials, Heart Valve Prosthesis, Heart Valves, Humans, Prosthesis Design, Treatment Outcome, Transcatheter Aortic Valve Replacement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review