Application of PLCL as a biodegradable polymer in biomedical engineering
Open accessThe DOI matches its Crossref record; 350 of the 350 references it cites were found in a registry or an index; 93 of the 223 sources its claims cite were checked for support.
Abstract
Poly (L-lactide-co-ε-caprolactone) (PLCL) is a novel polymer that has attracted considerable attention in the biomedical field due to its exceptional biocompatibility. However, a comprehensive and systematic summary of its diverse applications remains lacking. To address this gap, the present review outlines the physicochemical properties of PLCL and the factors that influence them. Additionally, it consolidates the most commonly employed processing and preparation methods for PLCL in biomedical applications. The review further provides a systematic overview of current applications of PLCL in various biomedical fields, including wound healing, cardiovascular stents, nerve repair, osteochondral tissue engineering, drug delivery, and screening. It also examines modification strategies aimed at enhancing PLCL performance. Ultimately, this review seeks to provide valuable insights for future research and development of PLCL in biomedical contexts.
Overview
CoChat Summary
TL;DR
This is a review of PLCL (poly(L-lactide-co-ε-caprolactone)) as a biodegradable biomaterial for biomedical engineering, summarizing its properties, processing methods, and applications. The paper argues that PLCL’s biocompatibility, tunable degradation, and adjustable mechanics make it useful across tissue engineering and other biomedical uses, but performance still often needs to be improved by blending or surface modification.
Key findings
- PLCL’s degradation can be tuned from weeks to years by changing the L-lactide/ε-caprolactone ratio and molecular weight; higher L-lactide content generally speeds degradation, while higher ε-caprolactone content slows it.
- The paper reports typical PLCL mechanical ranges of 20–60 MPa tensile strength, 400–600 MPa elastic modulus, and 100–500% elongation at break, with properties also affected by temperature, humidity, and processing method.
- PLCL is reviewed as a candidate material for wound healing, vascular stents/grafts, nerve repair, cartilage repair, bone repair, urethral/bladder repair, drug delivery, drug screening, and stem cell culture.
- The review highlights several processing routes for PLCL, including electrospinning, 3D printing, supercritical CO₂ foaming, membrane casting, and aerogel scaffolds; for example, 3D printing is described as enabling precise control of porosity, pore size, and scaffold microstructure.
Methods
- This is a narrative review, not an experimental study.
- Literature was retrieved using Web of Science; the authors first searched “PLCL”, then used topic-specific keywords such as “Electrospinning/coaxial electrospinning,” “3D printing,” “scCO₂,” “Membranes,” “Aerogel scaffolds,” and application terms including wound healing, vascular tissue engineering, cardiovascular tissue engineering, nerve tissue engineering, cartilage tissue engineering, bone tissue engineering, and urethral tissue engineering.
- The paper synthesizes the literature by organizing it into PLCL’s physicochemical properties, processing methods, tissue engineering applications, and other biomedical fields.
Limitations
- The paper states that PLCL’s mechanical strength may still be insufficient for high-load applications such as load-bearing bone repair and vascular stents.
- It also states that PLCL’s hydrophobicity can hinder cell adhesion, proliferation, and differentiation, and that many additives used to improve PLCL require further in vivo safety evaluation.
- Evident from the text: this is a review article, so its conclusions depend on the cited literature rather than new experimental data.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Morphology and diameter of PLCL nanofiber membranes [74]](https://figures.cochat.ai/paper-figures/dbb5ffa63751499f8effe805e71e710d/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-1.jpg)
![Fig. 2 a–d images of PLCL scaffolds prepared by LTD method at different magnifications [108]](https://figures.cochat.ai/paper-figures/a8e820b77dd64884a9d38f27b3f84738/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-2.jpg)
![Fig. 3 Characterization of scCO₂ porous scaffolds of PLCL/β-TCP Composites using SEM and μCT [13]](https://figures.cochat.ai/paper-figures/0fa6c4feb02b44d58003dabe3de06a60/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-3.jpg)
![Fig. 4 PLCL membrane with the compact layer and porous layer. A Macroscopic and microscopic images of the PLCL membrane (scale bar: 100 μm), B surface roughness (n = 5, *p < 0.05) and C microscopic image of the cross-section (scale bar: 100 μm) [123]](https://figures.cochat.ai/paper-figures/be64f6a16cd742db9979ae0cb637e540/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-4.jpg)
![Fig. 5 SEM images of PLCL/ADM and ADM aerogels scaffold [126]](https://figures.cochat.ai/paper-figures/d5bec210c8e1462ebdf968af29e9d4c3/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-5.jpg)
![Fig. 6 The treatment of infected wound by PLCL Janus dressing [147]](https://figures.cochat.ai/paper-figures/68ac0077a6a44f5fbdaa57b3e4ed8f13/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-6.jpg)
![Fig. 7 Triple-layer structure of PLCL vascular graft [154]](https://figures.cochat.ai/paper-figures/552357730c2f425aa64d01f8ea19dc56/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-7.jpg)
![Fig. 8 The process of fabricating PLCL/FDM novel platform for cardiomyocyte culture and coculture [173]](https://figures.cochat.ai/paper-figures/1aba6434c5174b29b63e0e4a6ef7af5c/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-8.jpg)
![Fig. 9 Schematic diagram of PVDF/PLCL/PEDOT electroactive artificial nerve conduit indirectly promoting the repair of damaged peripheral nerves by modulating the immune microenvironment [187]](https://figures.cochat.ai/paper-figures/11f9d968e1f74522816b1fd071cf5149/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-9.jpg)
![Fig. 10 Three-phase bionic BMSCs scaffold loaded with TGF-β promoting the regeneration of hyalene cartilage [196]](https://figures.cochat.ai/paper-figures/0667faf63e58411c82dc9def33374ab1/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-10.jpg)
![Fig. 11 Schematic diagram of ternary MXene-loaded PLCL/collagen nanofibrous scaffolds that promote spontaneous osteogenic differentiation [209]](https://figures.cochat.ai/paper-figures/c120b5c703684273a8c5386db34bf11c/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-11.jpg)
![Fig. 12 3D-printed PCL/PLCL urethral scaffold loaded with dual autologous cells in fibrin hydrogel [211]](https://figures.cochat.ai/paper-figures/2620c86f0cd3480da50c9ea53be963d8/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-12.jpg)
![Fig. 13 A Microscopic morphology of the ligament braided with 16 fibers (SB: PLCL scaffold blank; SP: PLCL-PLL scaffold; S1L: PLCL-PLL/HA-PLL scaffold). B Schematic diagram of the global structure of the multi-layer braided scaffold [214]](https://figures.cochat.ai/paper-figures/6ae950ffb98d46469c29d8ab41d1b04f/application-of-plcl-as-a-biodegradable-polymer-in-biomedical-engineering-figure-13.jpg)
Verification
Claims the paper makes
66 Valid · 12 Not valid · 70 Not checked · 37 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Poly (L-lactide-co-ε-caprolactone) (PLCL) has become an important biomaterial in biomedical engineering due to its excellent biocompatibility, tunable biodegradability, and multifunctional mechanical properties [1–4].”
§ Application of PLCL as a biodegradable polymer in biomedical engineering > Introduction
What the sources say
- Not checked — no full text of the sourcecites [1] Teng Y, Wang X, Song L, Yang J, Hou S, Lv Q, et al. 3D printed polycaprolactone/poly (L-lactide-co-ϵ-caprolactone) composite ureteral stent with biodegradable and antibacterial properties. Biomed Mater. 2025;20:025026. source
- Supportedcites [2] Zhan A, Chen L, Sun W, Tang Y, Chen J, Yu D, et al. Enhancement of diabetic wound healing using a core-shell nanofiber platform with sequential antibacterial, angiogenic, and collagen deposition activities. Mater Des. 2022;218:110660. source
The Introduction describes PLCL as a promising polymer for reinforcing wound-healing nanofibers. Section 3.2 calls it biodegradable and biocompatible with excellent mechanical properties, and reports that its degradation rate changed when other materials were added. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [3] Liu X, Liu S, Feng S, Wang X, Bai W, Xiao J, et al. Thermal, mechanical and degradation properties of flexible poly (1,3-trimethylene carbonate)/poly (L-lactide-co-ε-caprolactone) blends. J Polym Res. 2021;28:447. source
- Partly supportedcites [4] Kurki A, Hannula M, Miettinen S, Teittinen H, Paakinaho K, Hyttinen J, et al. Ascorbic acid 2-phosphate-releasing poly-l-lactide-co-epsilon-caprolactone membranes enhance tissue regeneration: first in vivo insights for pelvic organ prolapse. Regen Biomater. 2025;12:rbaf097. sourceExperimental — accuracy not yet measured
The Introduction describes PLCL as biodegradable, biocompatible and flexible, and lists several biomedical applications. The Results report different degradation rates and tensile properties for the tested PLCL formulations, but do not establish broadly tunable biodegradability or the claimed range of mechanical properties for PLCL generally. Page numbers are unavailable in our copy. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“PLCL surface modification or covalent binding of bioactive molecules, such as cell adhesion factors and cell growth factors, can further improve their compatibility with specific cells [25–27].”
§ Application of PLCL as a biodegradable polymer in biomedical engineering > Physical and chemical properties of PLCL > Biocompatibility
What the sources say
- Not checked — no full text of the sourcecites [25] Jin J, Limburg S, Joshi SK, Landman R, Park M, Zhang Q, et al. Peripheral nerve repair in rats using composite hydrogel-filled aligned nanofiber conduits with incorporated nerve growth factor. Tissue Eng Part A. 2013;19:2138–2146. source
- Partly supportedcites [26] Táborská J, Blanquer A, Brynda E, Filová E, Stiborová L, Jenčová V, et al. PLCL/PCL dressings with platelet lysate and growth factors embedded in fibrin for chronic wound regeneration. Int J Nanomed. 2023;18:595–610. sourceExperimental — accuracy not yet measured
The Introduction and Conclusion (pages not provided) describe PLCL/PCL nanofibers modified with a fibrin coating containing bioactive molecules. The Cell Viability results report improved growth of human endothelial cells with platelet lysate and added growth factors. The paper does not establish covalent binding of those molecules to PLCL/PCL, so that alternative in the claim is unsupported. (LLM, conf=0.86)
- Partly supportedcites [27] Wang Y, Wu T, Zhang J, Feng Z, Yin M, Mo X. A bilayer vascular scaffold with spatially controlled release of growth factors to enhance in situ rapid endothelialization and smooth muscle regeneration. Mater Des. 2021;204:109649. sourceExperimental — accuracy not yet measured
Section 3.3 reports improved proliferation of endothelial progenitor cells and smooth muscle cells on PLCL/collagen scaffolds incorporating VEGF and PDGF, respectively. Section 2.1 describes loading these factors into electrospun fibers, not covalently binding them or modifying the PLCL surface. The cellular benefit is supported, but the specified modification methods are not. (LLM, conf=0.86)
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“At the same time, the long-term existence of PLCL in vivo did not produce toxic accumulation in other organs [33].”
§ Application of PLCL as a biodegradable polymer in biomedical engineering > Physical and chemical properties of PLCL > Biocompatibility
What the sources say
- Could not verifycites [33] Kim A, Downer MA, Berry CE, Valencia C, Fazilat AZ, Griffin M. Investigating immunomodulatory biomaterials for preventing the foreign body response. Bioengineering. 2023;10:1411. sourceExperimental — accuracy not yet measured
The Foreign Body Response section discusses reactions to other implanted materials, but does not address PLCL or accumulation in other organs. Searches for PLCL and for long-term toxic accumulation found no passage in our copy that supports the claim; page numbers were not available. (LLM, conf=0.76)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“In addition to its inherent properties, PLCL’s adaptability through surface modification, blending with bioactive molecules, and processing through advanced manufacturing techniques such as electrospinning, 3D printing, and supercritical carbon dioxide (scCO₂) foaming has extended its use to multiple fields [11–13].”
§ Application of PLCL as a biodegradable polymer in biomedical engineering > Introduction
What the sources say
- Not checked — no full text of the sourcecites [11] Keun Kwon I, Kidoaki S, Matsuda T. Electrospun nano- to microfiber fabrics made of biodegradable copolyesters: structural characteristics, mechanical properties and cell adhesion potential. Biomaterials. 2005;26:3929–3939. source
- Not checked — no full text of the sourcecites [12] Bachtiar EO, Ritter VC, Gall K. Structure-property relationships in 3D-printed poly (L-lactide-co-ε-caprolactone) degradable polymer. J Mech Behav Biomed Mater. 2021;121:104650. source
- Partly supportedcites [13] Pitkänen S, Paakinaho K, Pihlman H, Ahola N, Hannula M, Asikainen S, et al. Characterisation and in vitro and in vivo evaluation of supercritical-co₂-foamed b-tcp/PLCL composites for bone applications. Eur Cells Mater. 2019;38:35–50. sourceExperimental — accuracy not yet measured
The Introduction and Composite manufacturing and characterisation sections describe blending PLCL with bioactive β-TCP and processing the composite by supercritical CO₂ foaming. The Discussion describes a compression treatment that changes the composite surface. The paper does not establish PLCL blending with bioactive molecules, PLCL processing by 3D printing, or extension of its use to multiple fields; its study concerns bone applications. Page numbers are unavailable in our copy. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Advances in polymer science have allowed precise control of the monomer and molecular weight ratios during PLCL synthesis, enabling customization of its degradation rate, mechanical strength, and cellular interactions to meet specific biomedical needs [9, 10].”
§ Application of PLCL as a biodegradable polymer in biomedical engineering > Introduction
What the sources say
- Partly supportedcites [9] Rajewska J, Kowalski J, Matys J, Dobrzyński M, Wiglusz RJ. The use of lactide polymers in bone tissue regeneration in dentistry–a systematic review. J Funct Biomater. 2023;14:83. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) says the ratio of glycolide to lactic units affects PLGA degradation and that PLA stereoisomers differ in mechanical properties. The Results and Discussion mention PLCL-containing materials and cell adhesion, but the cited review does not establish that controlling monomer and molecular-weight ratios during PLCL synthesis customizes all three claimed properties. (LLM, conf=0.82)
- Partly supportedcites [10] Wu S, Dong T, Li Y, Sun M, Qi Y, Liu J, et al. State-of-the-art review of advanced electrospun nanofiber yarn-based textiles for biomedical applications. Appl Mater Today. 2022;27:101473. sourceExperimental — accuracy not yet measured
The Surgical sutures section (page unavailable) lists PLCL among absorbable sutures described as having controllable degradation rates and mechanical properties. The Bone section (page unavailable) reports a cellular response to a PLCL-nanoyarn hydrogel. Neither passage links these properties or cellular interactions to precise control of monomer or molecular-weight ratios during PLCL synthesis. (LLM, conf=0.82)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
53 more claims · 24 with their cited sources checked
Create a free account to see all 185 claims and every source verdict.
- It may state two separate claims as one. 121
- Probably not a substantial claim. 20
Citations
Cites
Electrospinning and Electrospun Nanofibers: Methods, Materials, and Applications
Xue, J., Wu, T., Dai, Y., & Xia, Y. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00593 · Cited by 5,015
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
Photo-curing 3D printing technique and its challenges
Quan, H., Zhang, T., Xu, H., Luo, S., Nie, J., & Zhu, X. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2019.12.003 · Cited by 1,106
Recent insights into the cellular biology of atherosclerosis
Tabas, I., García-Cardeña, G., & Owens, G. K. (2015) · Journal of Cell Biology · doi:10.1083/jcb.201412052 · Cited by 1,016 · cited 1×
“Adding growth factors such as VEGF and PDGF to PLCL vascular scaffolds can effectively promote vascular endothelialization, accelerate migration and aggregation of endothelial cells and smooth muscle cells, and promote vascular regeneration and reconstruction [161].”
Advanced Therapeutic Dressings for Effective Wound Healing—A Review
Boateng, J., & Catanzano, O. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24610 · Cited by 946
3D printing of functional biomaterials for tissue engineering
Zhu, W., Ma, X., Gou, M., Mei, D., Zhang, K., & Chen, S. (2016) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.03.014 · Cited by 822 · cited 1×
“This excellent property makes 3D printing technology suitable for the design of customized materials and materials with hierarchical structures, such as customized bone, cartilage, and joint prostheses, multilayer skin wound dressings, and vascular stent coatings [91].”
Wound Healing: From Passive to Smart Dressings
Farahani, M., & Shafiee, A. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100477 · Cited by 794 · cited 1×
“External conditions such as temperature, humidity, oxygen supply, infection and other factors can affect the wound healing process [136].”
Solution blow spinning: A new method to produce micro‐ and nanofibers from polymer solutions
Medeiros, E. S., Glenn, G. M., Klamczynski, A. P., Orts, W. J., & Mattoso, L. H. C. (2009) · Journal of Applied Polymer Science · doi:10.1002/app.30275 · Cited by 780
Research works printed but not linked: 1
- Yu CP, Li X, Shen ZQ. Ring-opening homopolymerization of lactides. Prog Chem. 2007;19:136–144.
Cited by
Aranci, K., & Kızılkurtlu, A. A. (2026) · Polymers · doi:10.3390/polym18080974 · Cited by 2
Liu, Z., Zhao, C., Zhou, H., Shi, Z., Huang, R., Xu, L., Su, J., Chen, G., Zhao, Z., Li, Y., et al. (2026) · Stem Cell Research & Therapy · doi:10.1186/s13287-026-05072-8
“Furthermore, the considerable potential of PLCL-based scaffolds for wound treatment applications has been validated in multiple studies [22–24].”
Kongsak, C., Rithchumpon, P., Akkravijitkul, N., et al. (2026) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2026.146741
An injectable PLCL/CaHA microsphere composite gel for enhanced skin regeneration
Wang, X., Chen, X., Gao, R., et al. (2026) · Biomaterials Advances · doi:10.1016/j.bioadv.2026.215047
A “Vascular Band-Aid” strategy for proactive inhibition of post-anastomotic vascular complications
Xu, R., Yan, J., Li, X., Yin, X., Yang, Z., Zhou, Q., & Yi, B. (2026) · Regenerative Biomaterials · doi:10.1093/rb/rbag164
“PLCL, a Food and Drug Administration (FDA)- approved biodegradable elastomer with a well-established safety profile, has recently gained recognition for vascular applications owing to its excellent biocompatibility and capacity to support cell growth [13–15].”
Metadata
- Authors
- Zhao, Y., & Liu, H.
- Corresponding author
- Zhao, Yonggang
- Venue
- Journal of Materials Science Materials in Medicine
- Published
- 2026-02-27
- Volume
- 37
- Issue
- 1
- ISSN
- 0957-4530 (ISSN-L)
- 1573-4838
- PMC
- PMC12960328
- OpenAlex
- W7131777400
- Cited by
- 7
- References
- 325
- Citations by year
- 2026: 7
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor, 5 d)
- Locations
- Journal of Materials Science Materials in Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Keywords
- poly(L-lactide-co-ε-caprolactone), PLCL, biodegradable polymers, biocompatibility, physicochemical properties, wound healing, cardiovascular stents, nerve repair, osteochondral tissue engineering, drug delivery, polymer modification
- MeSH terms
- Animals, Biocompatible Materials, Biomedical Engineering, Humans, Materials Testing, Polyesters, Polymers, Wound Healing, Drug Delivery Systems, Absorbable Implants, Tissue Engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of PLCL as a biodegradable polymer in biomedical engineering. https://app.cochat.ai/papers/10.1007/s10856-026-07016-3
- The paper
- Zhao, Y., & Liu, H. (2026). Application of PLCL as a biodegradable polymer in biomedical engineering. Journal of Materials Science Materials in Medicine. https://doi.org/10.1007/s10856-026-07016-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.