The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Self‐Assembled Plasmonic Nanoring Cavity Arrays for SERS and LSPR Biosensing
Abstract
Self-assembled plasmonic nanoring cavity arrays are formed alongside the curvature of highly packed metallic nanosphere gratings. The sub-10-nm gap size is precisely tuned via atomic layer deposition and highly ordered arrays are produced over a cm-sized area. The resulting hybrid nanostructure boosts coupling efficiency of light into plasmons, and shows an improved SERS detection limit. These substrates are used for SERS detection of the biological analyte, adenine, followed by concurrent localized surface plasmon resonance sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Self-citation
Cited by
Fan, M., Andrade, G. F. S., & Brolo, A. G. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.11.049 · Cited by 533
Holographic metasurface gas sensors for instantaneous visual alarms
Kim, I., Kim, W.-S., Kim, K., Ansari, M. A., Mehmood, M. Q., Badloe, T., Kim, Y., Gwak, J., Lee, H., Kim, Y.-K., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe9943 · Cited by 281
Yoo, D., Gurunatha, K. L., Choi, H.-K., Mohr, D. A., Ertsgaard, C. T., Gordon, R., & Oh, S.-H. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b00732 · Cited by 173
Self-citationRhodium plasmonics for deep-ultraviolet bio-chemical sensing
Ahmadivand, A., Sinha, R., Kaya, S., & Pala, N. (2016) · Plasmonics · doi:10.1007/s11468-015-0117-x · Cited by 53
Metadata
- Authors
- Im, H., Bantz, K. C., Lee, S. H., Johnson, T. W., Haynes, C. L., & Oh, S.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2013-02-22
- Volume
- 25
- Issue
- 19
- Pages
- 2678-2685
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2043517244
- Cited by
- 273
- References
- 2
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self‐Assembled Plasmonic Nanoring Cavity Arrays for SERS and LSPR Biosensing. https://app.cochat.ai/papers/10.1002/adma.201204283
- The paper
- Im, H., Bantz, K. C., Lee, S. H., Johnson, T. W., Haynes, C. L., & Oh, S. (2013). Self‐Assembled Plasmonic Nanoring Cavity Arrays for SERS and LSPR Biosensing. Advanced Materials. https://doi.org/10.1002/adma.201204283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.